Introducción
This manual provides essential instructions for the safe installation, operation, and maintenance of your APC AP7922 32A 230V Switched Rack PDU. The AP7922 is a rack-mountable power distribution unit designed to provide advanced power control and monitoring capabilities for IT equipment in data centers and server rooms. It features AC 230V input, Ethernet 10/100 connectivity, and 16 output connectors, all within a 2U, 19-inch form factor.
Información importante de seguridad
Please read and understand all safety instructions before installing or operating this equipment. Failure to follow these instructions could result in electric shock, fire, or serious injury.
- Este dispositivo está diseñado únicamente para uso en interiores.
- Connect the PDU to a properly grounded power source.
- Do not attempt to open or service the PDU. Refer all servicing to qualified personnel.
- Ensure the total current draw of connected equipment does not exceed the PDU's maximum current rating (32 Amps).
- Desconecte la alimentación antes de realizar cualquier procedimiento de mantenimiento o instalación.
Contenido del paquete
Verifique que todos los artículos estén presentes al desembalar:
- APC AP7922 Switched Rack PDU
- Guía de instalación
- Soportes para montaje en bastidor
- Serial configuration cable
- CD de documentación
Características del producto
The APC AP7922 Switched Rack PDU offers the following key features:
- Salidas conmutadas: Remotely control power to individual outlets for power cycling, delayed sequencing, and load shedding.
- Gestión de red: Full-featured network management interface via Ethernet 10/100 for remote monitoring and control.
- Monitoreo actual: Monitor the aggregate current draw per PDU to prevent circuit overloads.
- Diseño de montaje en bastidor: Occupies 2U of rack space, compatible with standard 19-inch racks.
- Conectores de salida: Equipped with 16 C13 output connectors.
- Vol de entradatage: Supports AC 230V input.

Imagen: Frente view of the APC AP7922 Switched Rack PDU, showing the 16 C13 outlets and network interface.
Instrucciones de instalación
1. Montaje en bastidor
- Identify two available 2U spaces in your standard 19-inch equipment rack.
- Attach the provided rack-mounting brackets to the PDU using the screws supplied.
- Secure the PDU into the rack using appropriate rack screws. Ensure it is firmly seated and level.
2. Conexión de alimentación
- Connect the PDU's input power cord to a dedicated 230V, 32A power source. Ensure the power source is properly grounded.
- Do not overload the circuit. Verify that the total load of connected devices will not exceed 32 Amps.
3. Conexión de red
- Connect a standard Ethernet cable from the PDU's network port to your network switch or router.
- The PDU will obtain an IP address via DHCP by default. Refer to the full user manual for static IP configuration.
Instrucciones de funcionamiento
Powering On/Off Connected Devices
Once the PDU is powered and connected to the network, you can manage its outlets remotely.
- Access the PDU's web interfaz ingresando su dirección IP en un web navegador.
- Log in using the default credentials (refer to the full manual for details).
- Navigate to the outlet control section. From here, you can individually switch on, switch off, or cycle power to each of the 16 C13 outlets.
Monitoring Current Draw
El web interface also provides real-time monitoring of the aggregate current draw. This allows you to ensure that the PDU and its connected circuit are not overloaded.
Mantenimiento
- Limpieza: Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents.
- Actualizaciones de firmware: Compruebe el APC website for available firmware updates to ensure optimal performance and security. Follow the instructions provided with the firmware package for safe updating.
- Sistema de organización de cables: Ensure all power and network cables are neatly routed and secured to prevent accidental disconnections or damage.
Solución de problemas
| Problema | Posible causa | Solución |
|---|---|---|
| La PDU no se enciende. | No input power; tripped circuit breaker. | Verify the power cord is securely connected. Check the building's circuit breaker for the PDU's power source. |
| No se puede acceder web interfaz. | Incorrect IP address; network connectivity issue; PDU not powered. | Ensure the PDU is powered on. Verify network cable connection. Confirm the correct IP address. Check network settings. |
| Outlets do not switch. | Software issue; PDU fault. | Try restarting the PDU. If the issue persists, contact technical support. |
| Alarma de sobrecarga. | Total current draw exceeds PDU rating. | Disconnect non-essential equipment to reduce the load. Redistribute equipment across multiple PDUs if necessary. |
Especificaciones técnicas
| Característica | Detalle |
|---|---|
| Número de modelo | AP7922 |
| Marca | APC por Schneider Electric |
| Factor de forma | 2U Rack-mountable, 19-inch |
| Vol de entradatage | 230 Voltios AC |
| Corriente de entrada | 32 Amps |
| Vol de salidatage | 230 Voltios AC |
| Corriente de salida | 32 Amps (máx.) |
| Número de puntos de venta | 16 |
| Tipo de conector | C13 |
| Interfaz de red | Ethernet 10/100 |
| Quétage | 7360 vatios |
| Dimensiones (alto x ancho x profundidad) | 4.49 x 17.52 x 3.5 pulgadas |
| Peso | 0.7 kilogramos |
| Material | Metal |
| Color | Negro |
Garantía y soporte
Información de garantía
APC products typically come with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official APC website for detailed warranty terms and conditions specific to the AP7922 model.
Apoyo técnico
For technical assistance, troubleshooting, or to report issues, please contact APC customer support. You can find contact information and additional resources on the official Schneider Electric websitio: