Leviton 25249-TFB

Leviton 25249-TFB 15 Amp 125 voltios TampManual de instrucciones del receptáculo dúplex resistente a los rayos

Model: 25249-TFB

Introducción

This manual provides essential information for the safe and proper installation, operation, and maintenance of your Leviton 15 Amp, 125 Volt, Tamper-Resistant Duplex Receptacle (Model 25249-TFB). This commercial-grade, self-grounding receptacle features a straight blade design and a brass finish, engineered for demanding environments such as hotels, schools, hospitals, and commercial office buildings. It is designed to withstand rigorous use and offers enhanced safety features.

Información de seguridad

ADVERTENCIA: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

Advertencia sobre la Proposición 65: Este producto puede contener sustancias químicas reconocidas por el Estado de California como causantes de cáncer y defectos de nacimiento u otros daños reproductivos. Lavarse las manos después de la manipulación.

  • No utilice este dispositivo con cableado de aluminio. Úselo únicamente con cable de cobre o revestido de cobre.
  • Asegúrese de que todas las conexiones estén firmes y seguras para evitar el sobrecalentamiento.
  • This receptacle is tamper-resistant, designed to prevent insertion of foreign objects into the receptacle openings.
  • No exceda las clasificaciones eléctricas especificadas de 15 Amps y 125 voltios.

Características del producto

  • TampDiseño resistente a los errores: Meets NEC 2020 article 406.12, providing enhanced safety by preventing the insertion of single objects into the receptacle openings.
  • Grado comercial: Built to withstand demanding environments, ensuring durability and long-term performance.
  • Autoconexión a tierra: Features an integral self-grounding clip for quick and easy installation into a properly grounded metal box.
  • Construcción duradera: Thermoplastic receptacle face and body resist breakage.
  • Ready-To-Wire Unit: All-in-one design facilitates quick and easy installation.
Leviton 25249-TFB Tamper-Resistant Duplex Receptacle, Brass Finish

Image: Leviton 25249-TFB Tamper-Resistant Duplex Receptacle, Brass Finish. This image shows the front view of the receptacle with its brass faceplate and two tamptomacorrientes resistentes.

Configuración e instalación

Installation of electrical devices should only be performed by qualified personnel. Always ensure power is disconnected before beginning any work.

  1. Apagar la energía: Locate the circuit breaker or fuse that supplies power to the outlet where the receptacle will be installed. Turn it off and verify that power is off using a voltage probador.
  2. Retire el receptáculo viejo (si corresponde): Carefully remove the existing wall plate and receptacle from the electrical box. Disconnect the wires, noting their connections (hot, neutral, ground).
  3. Prepare los cables: Strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the circuit wires. Ensure wires are straight.
  4. Conectar cables:
    • Conectar el caliente (negro) wire to the brass-colored screw terminal.
    • Conectar el neutro (blanco) wire to the silver-colored screw terminal.
    • Conectar el tierra (cobre verde o desnudo) wire to the green screw terminal. This receptacle is self-grounding, meaning it will ground itself to a properly grounded metal box via its mounting strap.
    Asegúrese de que todas las conexiones de cables estén firmes y seguras.
  5. Receptáculo de montaje: Carefully fold the wires into the electrical box, then insert the new receptacle and secure it with the mounting screws provided.
  6. Instale la placa de pared: Attach the decorative wall plate (sold separately) over the receptacle.
  7. Restaurar energía: Vuelva a encender la energía en el disyuntor o en la caja de fusibles.
  8. Prueba: Test the receptacle with a known working appliance or receptacle tester to ensure proper function.
Leviton 25249-TFB Receptacle Back View

Imagen: Parte posterior view of the Leviton 25249-TFB receptacle, showing the screw terminals for wiring connections (hot, neutral, ground).

Instrucciones de funcionamiento

The Leviton 25249-TFB Tamper-Resistant Duplex Receptacle operates like a standard electrical outlet, with added safety features.

  • Conexión: Insert the plug of your appliance or device firmly into one of the two receptacle openings. The tamper-resistant shutters may require slightly more force to open than a traditional receptacle. Ensure both prongs are inserted simultaneously and evenly.
  • Desenchufar: Grasp the plug and pull it straight out from the receptacle. Do not pull by the cord.
  • Capacidad de carga: Do not overload the receptacle. The total current drawn by all connected devices should not exceed 15 Amps.

Mantenimiento

The Leviton 25249-TFB receptacle requires minimal maintenance.

  • Limpieza: To clean the receptacle face, ensure power is off at the circuit breaker. Use a soft, damp Paño. No utilice limpiadores abrasivos ni disolventes.
  • Inspección: Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power and have the receptacle inspected and replaced by a qualified electrician.
  • Consideraciones ambientales: While durable, avoid exposing the receptacle to excessive moisture or extreme temperatures beyond its operational specifications.

Solución de problemas

ProblemaPosible causaSolución
No hay energía en el receptáculo.Disyuntor disparado o fusible fundido. Conexión de cableado suelta.Check and reset the circuit breaker or replace the fuse. If problem persists, turn off power and check wiring connections. Consult an electrician if necessary.
El enchufe no se inserta fácilmente.TampLas persianas resistentes están activadas.Ensure both prongs of the plug are aligned and inserted simultaneously and firmly. Do not force the plug.
El receptáculo se siente caliente.Overloaded circuit. Loose wiring connection.Unplug some devices to reduce load. Turn off power and check wiring connections. If warmth persists, consult an electrician immediately.

Presupuesto

  • Modelo: 25249-TFB
  • Ampedad: 15 Amps
  • Volumentage: 125 voltios
  • Configuración: 5-15R
  • Número de polos: 2
  • Número de alambres: 3
  • Toma de tierra: Autoconexión a tierra
  • Material: Nylon (body), Brass (finish)
  • Color: Acabado de latón
  • Normas y certificaciones: UL 498, CSA C22.2, NOM 057 Approved
  • Tomas de corriente totales: 2

Garantía y soporte

Garantía: This Leviton product is backed by a 10-Year Limited Warranty. For detailed warranty terms and conditions, please refer to the official Leviton websitio o póngase en contacto con el servicio de atención al cliente.

Atención al cliente: For technical assistance, troubleshooting, or warranty claims, please visit the official Leviton website or contact their customer service department. Contact information can typically be found on the product packaging or the Leviton websitio.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.