Intermatic UWZ48E-240U

Intermatic UWZ48E-240U Hour Meter Instruction Manual

Model: UWZ48E-240U

1. Introducción

This manual provides detailed instructions for the installation, operation, and maintenance of the Intermatic UWZ48E-240U Hour Meter. This device is designed to accurately record operating hours for various electrical equipment. Please read this manual thoroughly before installation and operation to ensure proper function and safety.

2. Información de seguridad

ADVERTENCIA: Risk of electric shock. Installation and servicing should be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse box before installing or servicing the unit.

  • Siga siempre los códigos y regulaciones eléctricas locales.
  • Ensure the power supply matches the meter's voltage rating (240V AC, 60Hz).
  • No opere el medidor si parece dañado.
  • Mantenga a los niños alejados de las instalaciones eléctricas.

3. Producto terminadoview

The Intermatic UWZ48E-240U is a flush-mount hour meter designed for precise time tracking. It features a clear display for accumulated hours and offers both quick connect and screw terminals for versatile wiring options.

Intermatic UWZ48E-240U Hour Meter with dimensions

Figura 1: Frente view of the Intermatic UWZ48E-240U Hour Meter. The image shows the meter's face with the Intermatic logo, a six-digit hour display, and electrical ratings (UWZ 48-L, 110-127V~ 60Hz). Please note that while the image displays 110-127V, the product model UWZ48E-240U is rated for 240V AC, 60Hz as per specifications. Dimensions of 1.79 inches by 1.79 inches are indicated on the sides.

3.1 características clave:

  • Flush mount design with retaining bracket.
  • Combo quick connect and screw terminals.
  • 240V AC, 60Hz operation.
  • Construcción de plástico duradero.
  • Compact dimensions: 1.79"W x 1.79"H.

4. Instalación

4.1 Montaje

  1. Asegúrese de que la energía esté desconectada en la fuente.
  2. Create a panel cutout of 1.79" x 1.79" (45.5 x 45.5 mm). The panel thickness can be up to 0.35" (9 mm).
  3. Insert the hour meter into the cutout from the front of the panel.
  4. Secure the unit in position using the provided plastic slip-on retaining bracket from the rear of the panel.
  5. Opcional: For 72 mm square or round openings, an optional 72 mm bezel can be used (not included).

4.2 Cableado

The UWZ48E-240U features combo quick connect and screw terminals. Connect the meter in parallel with the load or circuit you wish to monitor. Ensure correct voltage (240V AC, 60Hz) is supplied to the meter terminals.

  • Conexión rápida: Use appropriate spade connectors for a secure connection.
  • Terminales de tornillo: Strip wire insulation to the recommended length, insert into the terminal, and tighten the screw firmly.

Después del cableado, asegúrese de que todas las conexiones estén seguras y aisladas antes de restablecer la energía.

5. Operación

The Intermatic UWZ48E-240U Hour Meter operates automatically when power is supplied to its terminals. The mechanical display will increment, showing the total accumulated operating hours. The meter does not have a reset function, providing a continuous record of equipment usage.

  • The display shows hours in a six-digit format, typically with the last digit representing tenths of an hour.
  • No user interaction is required for operation once installed and powered.

6. Mantenimiento

The UWZ48E-240U Hour Meter is designed for maintenance-free operation. However, periodic inspection is recommended to ensure optimal performance.

  • Limpieza: If necessary, gently wipe the display window with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Inspección: Periodically check wiring connections for tightness and ensure the meter is securely mounted.
  • Condiciones ambientales: Ensure the operating environment remains within the specified temperature range (up to 160°F / 71°C).

7. Solución de problemas

ProblemaPosible causaSolución
Meter display is blank or not incrementing.No power to the meter, incorrect wiring, or meter malfunction.
  • Verify power supply to the circuit.
  • Verifique que todas las conexiones del cableado tengan la polaridad y estén bien ajustadas.
  • Asegúrese del volumentage matches the meter's rating (240V AC).
  • If power and wiring are correct, the meter may require replacement.
Inaccurate hour readings.Intermittent power supply or meter malfunction.
  • Ensure a stable power supply to the monitored equipment.
  • If issues persist, the meter may require replacement.

8. Especificaciones

ModeloUWZ48E-240U
MarcaIntermático
Volumentage240 voltios
Frecuencia60 Hz
Calificación actual1 Amps
Tipo de conectorSpade, Screw Terminals
Tipo de montajeFlush Mount (Wall Mount)
MaterialPlástico
ColorBlanco
Dimensiones del producto (An x Al)1.79" x 1.79" (45.5 x 45.5 mm)
Recorte de panel1.79" x 1.79" (45.5 x 45.5 mm)
Max Panel Thickness0.35" (9 mm)
Clasificación de temperatura superior160 grados Fahrenheit (71 grados Celsius)
CertificacionesCSA
Peso del artículo0.2 libras

9. Garantía y soporte

For warranty information and technical support, please refer to the official Intermatic webSitio web o contacte con el departamento de atención al cliente. Conserve su recibo de compra como comprobante.

Puedes visitar el Tienda Intermatic en Amazon para obtener más información sobre el producto.

© 2023 Intermatic. Todos los derechos reservados. Información sujeta a cambios sin previo aviso.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.