This manual provides essential information for the safe and efficient use of your Gewiss GW30501 removable anti-blackout lamp. Please read it thoroughly before installation and operation.

1. Información importante de seguridad

Always observe basic safety precautions when installing, operating, and maintaining electrical equipment. Failure to do so may result in electric shock, fire, or serious injury.

  • Asegúrese de que la fuente de alimentación esté desconectada antes de cualquier trabajo de instalación o mantenimiento.
  • This device operates on 230 V AC 50/60 Hz. Verify your electrical system's compatibility.
  • No exponga el lamp al agua o humedad excesiva.
  • No intente abrir ni modificar el lamp or its components. Refer all servicing to qualified personnel.
  • Mantener fuera del alcance de los niños.

2. Producto terminadoview y componentes

The Gewiss GW30501 is a removable anti-blackout lamp designed to provide emergency lighting during power outages. It features a white LED lamp and an internal Ni-Mh battery for autonomous operation.

Gewiss GW30501 Removable Anti-Blackout Lamp

An image showing the compact design of the Gewiss GW30501 removable anti-blackout lamp, suitable for wall mounting.

Contenido del paquete:

  • 1 x Gewiss GW30501 Removable Anti-Blackout Lamp
  • Integrated Ni-Mh Power Batteries

3. Configuración e instalación

The GW30501 lamp is designed for wall mounting and integrates into a 2-module Playbus system.

Pasos de instalación:

  1. Desconectar la energía: Before beginning installation, ensure the main power supply to the installation area is completely disconnected at the circuit breaker.
  2. Preparar la ubicación de montaje: Identify a suitable wall location within your electrical system's 2-module Playbus slot.
  3. Conectar el cableado: Conecte con cuidado el lamp's electrical wiring to the 230 V AC, 50/60 Hz power supply terminals within the Playbus module. Ensure correct polarity and secure connections.
  4. Monte el Lamp: Securely insert the lamp into the 2-module Playbus slot on the wall. Ensure it is firmly seated.
  5. Carga inicial: Once installed, restore power. The lamp's internal Ni-Mh battery will begin charging. Allow at least 12-24 hours for the initial full charge to ensure optimal autonomy.

4. Instrucciones de funcionamiento

The Gewiss GW30501 lamp offers both automatic emergency lighting and a removable portable light function.

Automatic Anti-Blackout Function:

  • When installed and connected to the main power supply, the lamp's battery remains charged.
  • In the event of a power failure (blackout), the lamp will automatically illuminate using its internal battery, providing emergency lighting for up to 2 hours.
  • Once main power is restored, the lamp will turn off (if not manually activated) and begin recharging its battery.

Extraíble Lamp Función:

  • El lamp can be easily removed from its wall-mounted base.
  • Para activar la lamp when removed, gently touch the designated activation area (Touch-activated style). The white LED will illuminate.
  • Para apagar el lamp, touch the activation area again.
  • Cuando el lamp is reinserted into its wall base, it will resume its automatic anti-blackout function and recharge its battery.

5. Mantenimiento

Regular maintenance ensures the longevity and optimal performance of your anti-blackout lamp.

Cuidado de la batería:

  • The integrated Ni-Mh battery is designed for long life. To maintain its capacity, ensure the lamp is regularly connected to power to allow for charging cycles.
  • Si el lamp is stored for an extended period, fully charge it before storage and recharge every 3-6 months to prevent deep discharge.

Limpieza:

  • Limpiar el lamp's exterior with a soft, dry cloth.
  • No utilice limpiadores abrasivos, disolventes o productos químicos agresivos, ya que pueden dañar el acabado.

Verificación de funcionalidad:

  • Periodically test the anti-blackout function by temporarily cutting power to the circuit the lamp is connected to. The lamp debe iluminarse.
  • Test the removable lamp function by removing it from the base and activating it via touch.

6. Solución de problemas

If you encounter issues with your Gewiss GW30501 lamp, consulte los siguientes problemas y soluciones comunes:

ProblemaPosible causaSolución
Lamp does not light up during a power outage.Battery not charged or faulty. No power to the base.Asegúrese de que lamp has been connected to power for at least 24 hours. Check the circuit breaker for the lamp's power supply. If issues persist, contact support.
L extraíbleamp does not turn on when touched.Battery low or discharged. Faulty touch sensor.Devolver el lamp to its base for charging. Ensure the touch area is clean and dry.
Short autonomy (less than 2 hours).La batería no está completamente cargada o está envejeciendo.Allow for a full 24-hour charge. If the lamp is old, battery capacity may naturally decrease over time.
Lamp parpadea o se atenúa.Low battery. Loose connection.Asegúrese de que lamp is fully charged. Check the electrical connections at the wall base (with power disconnected).

If these solutions do not resolve the issue, please contact Gewiss customer support or a qualified electrician.

7. Especificaciones técnicas

Detailed specifications for the Gewiss GW30501 Removable Anti-Blackout Lamp:

CaracterísticaEspecificación
Número de modeloGW30501
MarcaGewiss
Vol. De la fuente de alimentacióntage230 V AC, 50 / 60 Hz
Autonomía2 horas
Lamp TipoLED blanco
Tipo de bateríaNi-Mh (included)
Number of Modules (Playbus)2
Dimensiones (L x An x Al)6.5 x 5 x 5 cm
Peso9.07 gramos
MaterialMetal
ColorGris
Tipo de instalaciónMontaje en pared
Cambiar estiloActivado al tacto
Usos específicosFor use during power outages or emergencies

8. Garantía y soporte

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your retailer or the manufacturer directly.

Fabricante: Gewiss

Please have your model number (GW30501) and purchase details available when contacting support.

© 2023 Gewiss. All rights reserved. Information in this manual is subject to change without notice.

Documentos relacionados - GW30501

Preview GEWISS Guía de la Scelta Rapida 2025-26
Descubra la guía rápida 2025-26 de GEWISS para soluciones de instalación, energía, construcción y movilidad, con aplicación de su innovación, sostenibilidad e historia social.
Preview Especificaciones técnicas y datos de los interruptores seccionadores rotativos GEWISS 70 RT HP
Comprehensive technical specifications for the GEWISS 70 RT HP series of rotary isolator switches. This document details models for insulating and aluminium enclosures, direct current (DC) photovoltaic applications, ATEX-certified versions for hazardous areas, and models designed for distribution boards and DIN rail mounting. It includes detailed electrical data, mechanical specifications, dimension tables, wiring diagrams, and auxiliary contact information.
Preview GEWISS Trade Catalogue 2025-26: Innovation and Sustainability
Explore the GEWISS Trade Catalogue 2025-26, featuring innovative solutions for buildings, industries, and infrastructures. Discover products for installation, energy, building, lighting, and mobility, alongside the company's commitment to sustainability and global presence.
Preview GEWISS GW68241N Declaration of Conformity and Technical Specifications
Manufacturer's Declaration of Conformity and technical details for the GEWISS GW68241N electrical assembly, including ratings, standards, directives, and component alternatives.
Preview GEWISS GW68236N Declaration of Conformity and Technical Specification
Manufacturer's Declaration of Conformity and technical details for the GEWISS GW68236N Q-DIN series electrical assembly, including specifications, standards, and component information.
Preview GEWISS GW 14 709 Connected Thermostat: Class IV and Class I Performance Specifications
Technical specifications for the GEWISS GW 14 709 Connected Thermostat, detailing performance characteristics for Class IV (2% tolerance) and Class I (1% tolerance) operations, with output waveform examples. Includes compliance with standard 811/2013.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.