APC BX1400UI

APC Back-UPS BX1400UI User Manual

Model: BX1400UI | Brand: APC

1. Introducción

The APC Back-UPS BX1400UI is an Uninterruptible Power Supply (UPS) designed to protect your electronic equipment from power outages, surges, and spikes. Featuring Line Interactive Technology and Automatic Voltage Regulation (AVR), this unit provides reliable battery backup and surge protection for connected devices. It includes six IEC 320 C13 outlets, a USB interface for communication, and data line protection.

Frente view of the APC Back-UPS BX1400UI Uninterruptible Power Supply, showing the power button and LED indicators.

Figura 1: Frente view of the APC Back-UPS BX1400UI.

2. Información importante de seguridad

  • Peligro eléctrico: Esta unidad contiene alto volumentage components. Do not attempt to open the UPS casing, especially when connected to power. Refer all servicing to qualified personnel.
  • Conexión directa: Always connect the UPS directly to a wall outlet. Do not use surge protectors, extension cords, or power strips with the UPS input.
  • Ventilación: Asegúrese de que haya una ventilación adecuada alrededor del SAI. No obstruya las aberturas de ventilación.
  • Olor inicial: A new unit may emit a distinct odor, often described as similar to burnt plastic. This is normal and typically dissipates after a few weeks of continuous operation in a well-ventilated area. It is not indicative of a malfunction.
  • Reemplazo de batería: User-performed battery replacement during the warranty period will void the product warranty. Refer to the Maintenance section for details.

3. Contenido del paquete

Verifique que su paquete contenga los siguientes elementos:

  • APC Back-UPS BX1400UI Unit
  • Two (2) IEC-C13 to IEC-C14 power cables (for connecting devices to the UPS)
  • Manual de usuario (este documento)

Nota: The input power cable (for connecting the UPS to the wall outlet) and the USB communication cable are typically No incluido and must be purchased separately if needed.

4. Configuración

4.1. Unpacking and Battery Connection

  1. Retire con cuidado el UPS de su embalaje.
  2. Locate the yellow battery connector on the rear panel of the UPS. This connector is typically disconnected for safe transport.
  3. Push the yellow battery connector firmly into its socket until it clicks into place. This activates the UPS battery circuits.

4.2. Conexión a la energía

  1. Connect the UPS to a grounded 230V AC wall outlet using an appropriate IEC-320 C14 input power cable (not included).
  2. Ensure the connection is direct to the wall outlet. Do not use surge protectors or extension cords.
  3. Allow the UPS to charge for at least 10 hours before connecting critical equipment to ensure full battery runtime.

4.3. Conexión de equipos

The BX1400UI features six IEC 320 C13 outlets for connecting your devices.

  • Tomas de corriente con respaldo de batería y protección contra sobretensiones: All six IEC-C13 outlets provide both battery backup and surge protection. Connect your computer, monitor, and other critical electronics to these outlets.
  • Protección de línea de datos: The rear panel includes RJ-11 ports labeled "DSL/Modem/Fax/Phone" for protecting your telephone or DSL line from surges. These ports are not suitable for Ethernet network connections.
  • Interfaz USB: Connect a USB Type B cable (not included) from the UPS to your computer for communication and to enable shutdown software functionality.
Rear panel of the APC Back-UPS BX1400UI, showing IEC-C13 outlets, USB port, battery connector, circuit breaker, and data line protection ports.

Figure 2: Rear panel connections of the APC Back-UPS BX1400UI.

5. Instrucciones de funcionamiento

5.1. Encendido / apagado

  • Para encender: Press and hold the power button on the front panel until you hear a short beep. The UPS will perform a self-test, and the 'On Line' LED will illuminate green.
  • Para apagar: Press and hold the power button until the UPS powers down.

5.2. Indicadores LED

The front panel features LED indicators to show the UPS status:

  • En línea (LED verde): Indicates the UPS is operating on utility power and providing power to connected equipment.
  • On Battery (Yellow LED): Indicates the UPS is operating on battery power during a power outage or brownout. A humming noise is normal during battery operation.
  • Reemplazar la batería (LED rojo): Indicates the battery needs to be replaced.
  • Sobrecarga (LED rojo): Indicates that the connected equipment exceeds the UPS's capacity. Disconnect non-essential equipment immediately.

5.3. Vol. Automáticotage Regulación (AVR)

El UPS corrige automáticamente los volúmenes menorestage fluctuations (sags and surges) without switching to battery power, thus preserving battery life. If voltage fluctuations exceed the AVR's correction range, the UPS will switch to battery power.

6. Características principales

  • Line Interactive Technology: Provides stable power by regulating voltage without constantly switching to battery.
  • Vol automáticotage Regulación (AVR): Corrige vol menortagy fluctuaciones sin utilizar la energía de la batería.
  • Copia de seguridad de la batería: Supplies power to connected equipment during outages.
  • Protección contra sobretensiones: Protects connected devices from damaging power surges and spikes.
  • 6 IEC 320 C13 Outlets: Standard outlets for computer equipment.
  • Interfaz USB: Enables communication with a computer for monitoring and controlled shutdown.
  • Protección de línea de datos: Safeguards telephone/DSL lines from surges.

7. Uso del software

The APC Back-UPS BX1400UI supports USB Human Interface Device (HID) class specifications, allowing it to be recognized by most operating systems without special drivers.

7.1. APC PowerChute Personal Edition (Windows)

For advanced monitoring and management on Windows systems, download the APC PowerChute Personal Edition software from the official APC webSitio. Este software le permite:

  • Monitor UPS status, power consumption, and battery charge.
  • Configure el apagado automático de su computadora durante cortes de energía prolongadostages.
  • Adjust UPS settings, such as alarm behavior (e.g., disable the beeper during battery operation).
  • Perform self-tests to ensure proper UPS functionality.

7.2. Linux Support (apcupsd / NUT)

For Linux environments, the UPS can be managed using `apcupsd` or Network UPS Tools (NUT). These tools provide similar monitoring and shutdown capabilities. Refer to the documentation for `apcupsd` or NUT for configuration details, typically involving specifying `UPSCABLE usb` and `UPSTYPE usb` for `apcupsd`, or using the `usbhid-ups` driver for NUT.

8. Mantenimiento

8.1. Reemplazo de la batería

The APC Back-UPS BX1400UI uses two 12V 7.2Ah sealed lead-acid batteries. The recommended replacement battery pack is APC RBC113.

  • During Warranty: If the unit is still under its 2-year warranty, battery replacement must be performed by Schneider Electric IT (SEIT) customer service. User-performed battery replacement during the warranty period will automatically void the warranty.
  • After Warranty: After the warranty period, batteries can be replaced by the user. However, due to the presence of high voltage components even when disconnected, it is highly recommended that this operation be performed by specialized personnel. If you choose to replace the batteries yourself, exercise extreme caution.
  • Procedimiento Terminadoview (for experienced users only): Disconnect the UPS from all power sources and connected equipment. Disconnect the yellow battery connector. Remove the rear panel screws, then the front panel (which is snap-fitted), and additional screws. Carefully access the battery compartment. Note the orientation and wiring of the existing batteries (taking photos is recommended) to ensure correct installation of the new batteries.

8.2. Restablecimiento del disyuntor

In case of an overload, the UPS may trip its circuit breaker. To reset, disconnect some equipment from the UPS, then press the circuit breaker button located on the rear panel (refer to Figure 2).

9. Solución de problemas

ProblemaPosible causaSolución
El UPS no se enciende.Battery connector disconnected; No input power.Ensure yellow battery connector is fully inserted. Verify UPS is plugged into a live wall outlet.
Initial strong odor.New unit manufacturing residue.This is normal. Ensure adequate ventilation. Odor will dissipate over time (typically a few weeks).
UPS emits a humming noise.Operating on battery power; Normal electrical noise.Humming is normal when on battery. If persistent and loud on utility power, ensure proper ventilation and check for loose connections.
'Overload' LED is lit.Demasiados equipos conectados.Disconnect non-essential equipment. Press the circuit breaker reset button on the rear panel.
'Replace Battery' LED is lit.La batería está llegando al final de su vida útil.Contact APC support or a qualified technician for battery replacement. Refer to Section 8.1.
Corta duración de la batería.La batería no está completamente cargada; la batería está llegando al final de su vida útil; carga excesiva.Ensure initial 10-hour charge. Reduce connected load. Consider battery replacement if old.

For more detailed troubleshooting, refer to the complete user manual available on the APC websitio.

10. Especificaciones

CaracterísticaEspecificación
ModeloBX1400UI
Capacidad (VA/vatios)1400 VA / 700 W
Vol de entradatage230 V CA
Frecuencia de entrada50 Hz
Vol de salidatage230V AC (simulated sine wave on battery)
Salidas de salida6 x IEC 320 C13 (batería de respaldo y protección contra sobretensiones)
Clasificación de protección contra sobretensiones273 julios
Tipo de bateríaBatería de plomo-ácido sellada
Configuración de la batería2 batería de 12 V y 7.2 Ah
Tiempo de recarga típico8 horas (al 90% de capacidad)
Runtime (at 700W load)Aproximadamente 1 minuto
Runtime (at 100W load)Aproximadamente 60 minutos
Dimensiones (alto x ancho x profundidad)21.5 cm x 13 cm x 33.6 cm
Peso4.7 kilogramos
Puertos de interfazUSB Type B, RJ-11 (Data Line Protection)
Runtime graph for APC Back-UPS 1400VA, 230V, AVR, IEC Sockets (BX1400UI), showing battery runtime in minutes versus load in watts.

Figure 3: Typical runtime graph for APC Back-UPS 1400VA.

11. Garantía y soporte

11.1. Garantía del producto

The APC Back-UPS BX1400UI comes with a Garantía limitada de 2 años A partir de la fecha de compra. Esta garantía cubre defectos de materiales y mano de obra en condiciones normales de uso. Conserve su comprobante de compra para reclamaciones de garantía.

Importante: Unauthorized opening of the unit or user-performed battery replacement during the warranty period will void the warranty.

11.2. Soporte técnico

For technical assistance, troubleshooting, or warranty service, please contact APC by Schneider Electric customer support. Visit the official APC website for contact information specific to your region, including phone numbers and online support resources.

Online resources often include FAQs, knowledge bases, and downloadable manuals that can provide further assistance.