Carel Easy Cool

Carel Easy Cool Electronic Thermostat User Manual

Model: Easy Cool

Introducción

This manual provides essential information for the installation, operation, and maintenance of your Carel Easy Cool Electronic Thermostat. Please read these instructions carefully before using the device to ensure proper function and safety.

The Carel Easy Cool thermostat is designed for precise temperature control in cooling applications. It features a setpoint, differential, and defrost cycle management.

Configuración e instalación

Diagrama de cableado

Consulte el siguiente diagrama para ver las conexiones eléctricas correctas. Asegúrese de que todas las conexiones sean seguras y cumplan con la normativa eléctrica local.

Wiring diagram for Carel Easy Cool thermostat showing connections for power, NTC probes, and relays.

Descripción de la imagen: This diagram illustrates the wiring connections for the Carel Easy Cool thermostat. Terminals 1, 2, and 3 are for power input (L, N, 230V~). Terminals 4, 5, and 6 are for NTC probes, specifically for ambient temperature (AMB.T.) and defrost temperature (DEF.T.). The diagram also indicates relay ratings: 12(2)A, EN60730-1, 250 Vac, 12A 5FLA 30LRA UL 873.

Montaje

The thermostat is designed for wall mounting. Ensure the mounting surface is stable and allows for proper ventilation.

Dimensional drawing of the Carel Easy Cool thermostat showing length, width, and depth in millimeters and inches.

Descripción de la imagen: This image provides the physical dimensions of the Carel Easy Cool thermostat. The top view shows a length of 81 mm (3.19 inches) and a width of 36.1 mm (1.42 inches) to 38.6 mm (1.52 inches). The side view shows a depth of 57.3 mm (2.26 inches) to 71.5 mm (2.81 inches), with an overall length including connectors of 79.5 mm (3.13 inches).

Conexión de sonda

Connect the two NTC probes as indicated in the wiring diagram. One probe is typically for ambient temperature sensing, and the other for defrost temperature sensing.

  • Ensure probes are correctly positioned for accurate temperature readings.
  • Avoid placing probes near heat sources or direct airflow that could skew readings.

Instrucciones de funcionamiento

The Easy Cool thermostat is pre-programmed with standard settings for ease of use.

  • Punto fijo: The default setpoint is 3 °C. This is the desired temperature the thermostat will maintain.
  • Diferencial: The default differential is 2 °C. This value determines the temperature range around the setpoint before the cooling system activates or deactivates. For example, if the setpoint is 3 °C and the differential is 2 °C, the cooling will turn on at 5 °C (3+2) and turn off at 3 °C.
  • Ciclo de descongelación: The thermostat includes a defrost function. The default defrost cycle is 20 minutes every 6 hours.
  • Mostrar: The device features a digital display for temperature readings and status indicators.
  • Método de control: The primary control method is via a mechanical knob, with app control also indicated.

For detailed programming and adjustment of parameters, refer to the comprehensive technical manual available from Carel.

Mantenimiento

To ensure optimal performance and longevity of your Carel Easy Cool thermostat, follow these general maintenance guidelines:

  • Limpieza: Limpie periódicamente el exterior del termostato con un paño suave y seco. No utilice limpiadores abrasivos ni disolventes.
  • Inspección: Regularly inspect wiring connections for any signs of wear, corrosion, or looseness.
  • Comprobación de la sonda: Ensure NTC probes are clean and securely in place. Dust or debris on probes can affect accuracy.
  • Ventilación: Ensure the thermostat's ventilation openings are not obstructed to prevent overheating.

Para cualquier mantenimiento o reparación interna, contacte con personal de servicio calificado.

Solución de problemas

If you encounter issues with your thermostat, consider the following common checks:

  • Sin energía: Check the power supply to the thermostat and ensure all wiring connections are correct and secure. Verify the circuit breaker.
  • Lectura de temperatura incorrecta: Ensure NTC probes are properly connected and positioned. Check for any physical damage to the probes or their wiring.
  • Cooling System Not Activating: Verify the setpoint and differential settings. Ensure the cooling system itself is operational. Check relay connections.
  • Defrost Issues: Confirm defrost cycle settings. Check the defrost probe connection.

If problems persist after these checks, consult a qualified technician or Carel customer support.

Especificaciones técnicas

CaracterísticaEspecificación
Marcacarel
Nombre del modeloEasy Cool
Rango de temperatura-50 a +90 °C
Volumentage230 V, 50 / 60 Hz
Sondas incluidas2 NTC probes
Relés3 relays, 12(5)A + 2 x 8(2)A
Default Setpoint3 °C
Default Differential2 °C
Ciclo de descongelación20 minutes every 6 hours
Tipo de controladorpomo mecanico
Tipo de control de temperaturaEnfriamiento
Tecnología de conectividadCableado
Tipo de montajeMontaje en pared
Tipo de pantallaDigital
ColorNegro

Garantía y soporte

For warranty information, technical support, or service inquiries, please contact your local Carel distributor or visit the official Carel webSitio. Conserve su recibo de compra como comprobante de compra.

© 2023 Carel. Todos los derechos reservados.