Thank you for choosing the BN-LINK Digital Countdown Wall Timer Switch. This device is designed to provide convenient and energy-efficient control over your lights and exhaust fans. With its simple push-button operation and preset countdown options, you can easily automate shut-off times, helping to conserve energy and enhance your daily routine. This manual provides detailed instructions for installation, operation, and safety to ensure optimal performance and longevity of your timer switch.
¿Qué hay en la caja?
- BN-LINK Digital Countdown Wall Timer Switch
- Placa de pared
- Tuercas de alambre
- Tornillos de montaje
- Manual de instrucciones

Image: Package contents showing the timer switch, wire nuts, and wall plate.
Presupuesto
| Modelo | BND-60/U110b-1 |
| Modo de operación | ENCENDIDO APAGADO |
| Calificación actual | 15 Amps |
| Vol de funcionamientotage | 125 voltios |
| Tipo de contacto | Normalmente cerrado |
| Tipo de conector | Clamp |
| Tipo de interruptor | Botón pulsador |
| Terminal | Tornillo |
| Material | Plástico |
| Dimensiones del artículo (largo x ancho x alto) | 4.2 x 1.8 x 2 pulgadas |
| Tipo de circuito | 1 vías |
| Tipo de montaje | Montaje en pared |
| Tipo de actuador | Botón pulsador |
| Número de posiciones | 1 |
| Clasificación de temperatura superior | 122 grados Fahrenheit |
| Método de control | Tocar |
| Quétage | 1875 vatios |
| Color | Blanco |
| Calificación de protección internacional | IP54 |
| Proceso de dar un título | ETL Listed (Conforms to UL Std. 60730-1, 60730-2-7) |

Image: Size details of the timer switch, including its dimensions and included accessories like wire nuts and face plate.
Información importante de seguridad
- ADVERTENCIA: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that the power is off before wiring.
- Este dispositivo requiere un Cable neutro for proper operation. Ensure your electrical box has a neutral wire available.
- For single-pole installations only. Do not use in 3-way or multi-way switch applications.
- Consulte a un electricista calificado si no está seguro acerca de alguna parte del proceso de instalación.
- Rated 125V, 60 Hz, 15A/1875W Resistive or General Purpose, 10A/1250W Ballast or Tungsten, ½ HP, TV-5. Do not exceed these ratings.
Instrucciones de instalación
- Apague la energía: Before beginning any electrical work, ensure the power to the switch location is turned off at the circuit breaker or fuse box. Verify power is off using a voltage probador.
- Eliminar el interruptor existente: Carefully remove the existing wall plate and switch from the electrical box. Disconnect the wires from the old switch, noting which wire was connected to which terminal.
- Identificar cables: Identify the following wires in your electrical box:
- Alambre caliente (línea): Generalmente de color negro, trae energía desde el disyuntor.
- Cable de carga: Typically black, connects to the fan or light fixture.
- Cable neutro: Generalmente de color blanco, necesario para este interruptor temporizador.
- Cable a tierra: Generalmente cobre verde o desnudo.
- Cablear el interruptor del temporizador: Connect the wires from your electrical box to the corresponding wires on the BN-LINK timer switch using the provided wire nuts.
- Conectar el Alambre caliente from the wall to the Alambre negro del temporizador
- Conectar el Cable de carga Desde el accesorio hasta el Cable rojo del temporizador
- Conectar el Cable neutro from the wall to the Alambre blanco del temporizador
- Conectar el Cable de tierra from the wall to the Cable verde del temporizador
- Monte el interruptor: Carefully push the wired timer switch into the electrical box. Secure it with the provided mounting screws.
- Instale la placa de pared: Attach the included wall plate over the timer switch.
- Restaurar energía: Vuelva a encender la energía en el disyuntor.

Image: Detailed wiring diagram for the timer switch, emphasizing the neutral wire requirement.
Video: An instructional video demonstrating the installation and basic operation of the BN-LINK Countdown Digital In-wall Timer Switch.
Instrucciones de funcionamiento
The BN-LINK Digital Countdown Wall Timer Switch features intuitive push-button controls for easy operation. Each button has a small LED indicator that illuminates when active.
1. Preset Countdown Functions
The timer offers six preset countdown durations: 5 minutes, 15 minutes, 30 minutes, 60 minutes (1 hour), 2 hours, and 4 hours. To activate a countdown:
- Press the button corresponding to your desired countdown time (e.g., "5 Min", "15 Min", "1 Hour").
- The LED indicator next to the selected button will illuminate, and the connected device (fan/light) will turn on.
- The device will automatically turn off once the countdown period expires.
2. Encendido y apagado manual
The "ON/OFF" button allows for continuous operation or immediate shut-off, overriding any active countdown or repeat function.
- Press "ON/OFF" once to turn the connected device on indefinitely. The "ON/OFF" LED will illuminate.
- Press "ON/OFF" again to turn the connected device off immediately. The "ON/OFF" LED will turn off.
3. Función de repetición
The "REPEAT" button activates a daily repeat for the currently selected countdown program.
- While a countdown program is active, press the "REPEAT" button. The "REPEAT" LED will illuminate.
- The selected countdown will automatically run at the same time every day.
- To deactivate the repeat function, press the "REPEAT" button again. The LED will turn off.
- Alternatively, pressing the "ON/OFF" button will also cancel the repeat function.

Imagen: Más alláview of timer switch features, including LED indicators, one-button programming, repeat function, and manual ON/OFF.

Image: The repeat button on the timer switch, which allows for daily automatic countdowns.
Aplicaciones versátiles
This timer switch is suitable for a wide range of indoor applications, enhancing convenience and energy savings in various areas of your home. It is compatible with incandescent, fluorescent, and LED lighting, as well as bathroom exhaust fans and heaters.
- Baños: Automatically turn off exhaust fans after a set period to manage humidity.
- Closets & Pantries: Ensure lights turn off after you leave.
- Garages & Basements: Prevent lights from being left on accidentally.
- Lavanderías: Control lighting or fan operation.
- Sauna Rooms: Set specific durations for sauna use.

Imagen: Examples of various rooms and settings where the timer switch can be effectively utilized.
Solución de problemas
If you encounter any issues with your BN-LINK Digital Countdown Wall Timer Switch, please review the installation steps and operating instructions carefully. Ensure all wire connections are secure and that the power supply is active. If problems persist, please contact customer support for assistance.
Garantía y atención al cliente
The BN-LINK Digital Countdown Wall Timer Switch is ETL listed, conforming to UL Std. 60730-1 and 60730-2-7, ensuring safety and reliability. For any questions regarding installation, operation, or product support, please do not hesitate to contact BN-LINK customer service. We are committed to providing quality products and support to our customers.
Contact information can typically be found on the product packaging or the official BN-LINK websitio.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.