ECOELER YM2106

ECOELER YM2106 Wall Switch Vacancy & Occupancy Sensor Instruction Manual

Modelo: YM2106

Introducción

This manual provides comprehensive instructions for the installation, operation, and maintenance of the ECOELER YM2106 Wall Switch Vacancy & Occupancy Sensor. This device is designed to automatically control lighting and motor loads based on motion detection, offering energy savings and convenience. It supports both manual-on (vacancy sensor) and automatic-on (occupancy sensor) switching modes.

Información importante de seguridad

WARNING: RISK OF ELECTRIC SHOCK. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker before installation or servicing. Installation should be performed by a qualified electrician or in accordance with local electrical codes.

  • Lea todas las instrucciones antes de la instalación.
  • Do not install with power on.
  • Sólo para uso en interiores.
  • Asegúrese de que las conexiones del cableado sean seguras.
  • Vol de funcionamientotage: 120/277Vac, 60Hz.
  • Neutral wire is not required for operation.

Contenido del paquete

Verifique que todos los componentes estén presentes antes de comenzar la instalación:

  • ECOELER YM2106 Sensor Switch
  • placa de pared (1)
  • Tornillos
  • tapas de cableado
  • Manual de instrucciones de instalación (este documento)

Presupuesto

Número de modeloYM2106
Volumentage120/277Vac, 60Hz
Tipo de detecciónPIR (infrarrojos pasivos)
Cobertura180-degrees; 720-square feet
Configuración de retardo de tiempo5 segundos a 30 minutos (ajustable)
Ambient Light LevelAdjustable (holds lighting off when natural light is sufficient)
AlambradoNeutral wire not required
Tipos de cargaIncandescent, Fluorescent, LED, CFL
CertificacionesUL Listed, Title-24 Compliant
Dimensiones4.12 x 1.69 x 1.75 pulgadas
MaterialPlástico y metal

Instrucciones de instalación

Antes de comenzar: Turn OFF power at the circuit breaker or fuse box. Ensure the power is completely disconnected before proceeding.

  1. Preparar el cableado: Carefully remove the existing wall switch from the electrical box. Identify the LINE (hot), LOAD, and GROUND wires. The ECOELER YM2106 does not require a neutral wire.
  2. Conectar cables:
    • Conectar el alambre negro Desde el sensor hasta el LINE (hot) wire from the electrical box. Secure with a wiring cap.
    • Conectar el cable rojo Desde el sensor hasta el LOAD wire (to the light fixture/motor) from the electrical box. Secure with a wiring cap.
    • Conectar el cable verde Desde el sensor hasta el GROUND wire from the electrical box. Secure with a wiring cap.
    • Cap off any unused wires in the electrical box, such as a neutral wire, if present.
  3. Monte el sensor: Gently fold the wires into the electrical box. Insert the sensor into the electrical box and secure it with the provided screws.
  4. Instale la placa de pared: Attach the decorative wall plate over the sensor and secure it.
  5. Restaurar energía: Encienda la alimentación en el disyuntor.
  6. Funcionalidad de prueba: The green LED indicator light on the sensor will flash when motion is detected, confirming active detection.

Note: If you are unsure about any wiring steps, consult a qualified electrician.

Operación

The ECOELER YM2106 sensor supports two primary modes of operation: Vacancy (Manual-On) and Occupancy (Automatic-On).

Vacancy Sensor (Manual-On) Mode

In this mode, the lights/motor will only turn ON when you manually press the switch button. Once ON, the sensor will keep the lights/motor ON as long as motion is detected within its coverage area. The lights/motor will turn OFF automatically after no motion is detected for the set time delay.

Occupancy Sensor (Automatic-On) Mode

In this mode, the lights/motor will turn ON automatically when motion is detected within the sensor's coverage area. The lights/motor will remain ON as long as motion is detected and will turn OFF automatically after no motion is detected for the set time delay.

To switch between modes or adjust settings, refer to the "Configuration and Settings" section.

Configuración y ajustes

The ECOELER YM2106 sensor features adjustable settings for time delay, sensitivity, and ambient light level. These adjustments are typically made via small dials or switches located on the sensor itself, often behind the wall plate.

  • Retraso de tiempo: This setting determines how long the lights/motor remain ON after the last detected motion. It is adjustable from 5 seconds to 30 minutes. Adjust clockwise for longer delays, counter-clockwise for shorter delays.
  • Sensibilidad: This controls the sensor's responsiveness to motion. Higher sensitivity detects smaller movements or movements at greater distances. Lower sensitivity requires more significant motion or closer proximity. Adjust as needed to prevent false triggers or missed detections.
  • Ambient Light Level (Photocell): This setting allows the sensor to hold the lights/motor OFF if sufficient natural light is present in the room, even if motion is detected. This feature helps save energy by preventing artificial lighting from turning on unnecessarily. Adjust to your desired light threshold.

Consult the diagrams on the sensor unit itself for the exact location and labeling of these adjustment controls.

Mantenimiento

  • Limpieza: Periodically wipe the sensor lens with a soft, dry cloth to remove dust or debris that may obstruct detection. Do not use abrasive cleaners or solvents.
  • Inspección: Regularly check the sensor and wall plate for any signs of damage or loose connections.
  • No hay piezas que el usuario pueda reparar: The sensor contains no user-serviceable parts. Do not attempt to open or repair the unit.

Solución de problemas

ProblemaPosible causaSolución
Lights/Motor do not turn ON.
  • No hay energía en el sensor.
  • Cableado incorrecto.
  • Sensor in Vacancy (Manual-On) mode and not manually activated.
  • Ambient light level setting too high.
  • Sensor lens obstructed.
  • Revise el disyuntor.
  • Verify wiring connections (LINE, LOAD, GROUND).
  • Press the switch button to activate.
  • Adjust ambient light level setting.
  • Limpie la lente del sensor.
Lights/Motor turn ON unexpectedly.
  • Sensor in Occupancy (Automatic-On) mode.
  • Configuración de alta sensibilidad.
  • Motion from outside coverage area (e.g., HVAC drafts, pets).
  • Switch to Vacancy mode if desired.
  • Reducir la configuración de sensibilidad.
  • Adjust sensor placement or reduce sensitivity.
Lights/Motor turn OFF too quickly or too slowly.
  • Incorrect time delay setting.
  • Sensor not detecting continuous motion.
  • Adjust time delay setting.
  • Ensure sensor has a clear line of sight to the activity area. Increase sensitivity if necessary.

Garantía y soporte

For warranty information or technical support, please contact ECOELER customer service. Retain your proof of purchase for warranty claims.

La información de contacto normalmente se encuentra en el empaque del producto o en la página oficial del fabricante. websitio.

Información para los medios