1. Introducción
This manual provides essential instructions for the safe installation, operation, and maintenance of your BEST LEDR-1 LED Emergency Light. Please read this manual thoroughly before installation and retain it for future reference. The LEDR-1 is designed to provide reliable emergency illumination during power outages, ensuring safety in commercial and residential environments.
2. Instrucciones de seguridad importantes
ADVERTENCIA: Riesgo de descarga eléctrica. Desconecte la alimentación antes de realizar cualquier instalación o mantenimiento.
- Todos los servicios deben ser realizados únicamente por personal calificado.
- No lo monte cerca de calentadores de gas o eléctricos.
- Ensure the electrical wiring is properly grounded.
- No lo utilice en exteriores. Esta unidad está diseñada solo para uso en interiores.
- No permita que los cables de alimentación entren en contacto con superficies calientes.
- Mount the unit in locations and at heights where it will not be subjected to tampmanipulación por parte de personal no autorizado.
- El uso de equipos accesorios no recomendados por el fabricante puede provocar una condición insegura.
- No utilice este equipo para ningún otro fin que no sea el previsto.
- Allow battery to charge for a minimum of 24 hours after installation before testing.
3. Contenido del paquete
Verifique que todos los componentes estén presentes y sin daños al abrir el paquete:
- BEST LEDR-1 LED Emergency Light Fixture (1 unit)
- Herrajes de montaje (tornillos, anclajes)
- Tuercas de alambre
- Manual de usuario (este documento)
- AA NiCAD Battery (pre-installed or included separately)
4. Producto terminadoview
The BEST LEDR-1 is a compact and efficient LED emergency light designed for wall-mount applications. It features a durable white thermoplastic housing and two adjustable LED lamp heads, providing 98 lumens of bright, white light (5000 Kelvin) during emergency situations. The unit operates on 120 Volts AC and includes a rechargeable NiCAD battery for backup power.

Figura 1: Frente view of the BEST LEDR-1 Emergency Light. This image shows the compact white thermoplastic housing with two adjustable LED lamp cabezas.
Características principales:
- Alojamiento: White Thermoplastic
- Fuente de luz: 2 LED heads
- Volumentage: 120 Voltios AC
- Batería: NiCAD, 90 minutes average life
- Salida de luz: 98 lúmenes
- Dimensiones: Aproximadamente 14.75" de largo x 3.75" de ancho x 3.75" de alto
5. Instalación
The LEDR-1 is designed for flush wall mounting. Follow these steps for proper installation:
- Desconexión de energía: Before beginning any installation, ensure that the main power supply to the circuit where the emergency light will be installed is turned OFF at the circuit breaker or fuse box.
- Ubicación de montaje: Select a suitable wall location for mounting. The unit should be mounted at a height and in a position that allows for optimal light distribution during an emergency. Ensure the mounting surface is solid and can support the fixture's weight.
- Preparar la superficie de montaje: Use the provided mounting hardware (screws and anchors) to secure the mounting plate or backplate of the emergency light to the wall. If the unit has a separate mounting plate, attach it first.
- Conexiones de cableado:
- Conectar el alambre negro from the emergency light to the cable caliente (vivo) from the building's electrical supply.
- Conectar el cable blanco from the emergency light to the cable neutro from the building's electrical supply.
- Conectar el cable verde from the emergency light to the cable de tierra from the building's electrical supply.
- Use the provided wire nuts to secure all connections. Ensure all connections are tight and properly insulated.
- Conexión de la batería: If the battery is not pre-connected, connect the battery pack to the circuit board. Ensure correct polarity.
- Accesorio seguro: Carefully tuck all wires into the junction box or fixture housing. Secure the emergency light fixture to the mounting plate or wall according to the specific design of the unit.
- Restaurar energía: Once the installation is complete and all connections are secure, restore power to the circuit. The CHARGE INDICATOR light on the unit should illuminate, indicating that the battery is charging.
- Carga inicial: Allow the battery to charge for a minimum of 24 hours before performing the first test.
6. Operación
The BEST LEDR-1 Emergency Light operates automatically:
- Encendido de CA: When AC power is supplied to the unit, the charge indicator light will be ON, and the battery will be charging. The LED lamp heads will remain OFF.
- Poder Outage: In the event of an AC power failure, the emergency light will automatically switch to battery backup mode, and the LED lamp heads will illuminate. The unit will provide emergency lighting for approximately 90 minutes.
- Se restableció la alimentación de CA: When AC power is restored, the LED lamp heads will turn OFF, and the unit will revert to charging the battery.
- Botón de prueba: A test button is located on the unit. Pressing this button simulates an AC power failure, allowing you to verify that the emergency lights function correctly. Release the button to return to normal operation.
- L ajustableamp Cabezas: The two LED lamp heads can be manually adjusted to direct light to desired areas.
7. Mantenimiento
Regular maintenance ensures the longevity and reliability of your emergency light.
Prueba de batería:
Perform the following tests according to local codes and regulations (typically monthly and annually):
- Prueba mensual: Press and hold the test button for at least 30 seconds. The LED lamp heads should illuminate. Release the button; the lights should turn off, and the charge indicator should be ON.
- Prueba anual: Disconnect AC power to the unit for a full 90 minutes. The LED lamp heads should remain illuminated for the entire duration. Reconnect AC power; the lights should turn off, and the charge indicator should be ON. If the unit fails to operate for the full 90 minutes, the battery may need replacement.
Limpieza:
Clean the exterior of the unit and lamp heads periodically with a soft, damp Paño. No utilice limpiadores abrasivos ni disolventes.
Reemplazo de batería:
The NiCAD battery has a limited lifespan. If the unit fails the annual 90-minute test, the battery likely needs replacement. Contact a qualified electrician or the manufacturer for battery replacement instructions and compatible battery types.
8. Solución de problemas
| Problema | Posible causa | Solución |
|---|---|---|
| Emergency lights do not turn ON during power outage or when test button is pressed. |
|
|
| Charge indicator light is OFF when AC power is present. |
|
|
| Emergency lights do not stay ON for 90 minutes during annual test. |
|
|
9. Especificaciones
| Característica | Detalle |
|---|---|
| Número de modelo | LEDR-1 |
| Marca | MEJOR |
| Material de la carcasa | White Thermoplastic |
| Tipo de fuente de luz | LED (2 heads) |
| Volumentage | 120 Voltios AC |
| Quétage | 2 vatios |
| Brillo | 98 lúmenes |
| Eficiencia | 49 lúmenes/vatio |
| Temperatura de color | 5000 Kelvin |
| Tipo de batería | NiCAD (1 AA battery required, included) |
| Average Battery Life (Emergency Mode) | 90 minutos |
| Tipo de instalación | Montaje empotrado en pared |
| Uso en interiores y exteriores | Solo en interiores |
| Dimensiones del producto (L x An x Al) | 14.75" x 3.75" x 3.75" |
| Peso del artículo | 0.01 onzas |
| Método de control | Remote (Test Button) |
10. Garantía y soporte
The BEST LEDR-1 LED Emergency Light comes with a full manufacturer warranty. For specific warranty details, claims, or technical support, please refer to the warranty card included with your product or contact Best Lighting Products directly. Keep your purchase receipt as proof of purchase.
For assistance, please contact Best Lighting Products customer service.