1. Introducción
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Duluth Forge DLS-30T-2 Dual Fuel Ventless Fireplace Logs Set. Please read all instructions carefully before installation and use. Retain this manual for future reference.
2. Información de seguridad
ADVERTENCIA: La instalación, el ajuste, la alteración, el servicio o el mantenimiento incorrectos pueden causar lesiones o daños materiales. Consulte este manual. Para obtener ayuda o información adicional, consulte a un instalador cualificado, una agencia de servicio técnico o la empresa de gas.
- Uso exclusivo en interiores: This appliance is designed for indoor use exclusively.
- Operación sin ventilación: This unit is ventless and does not require an outside duct or chimney. Ensure adequate ventilation as specified by local codes.
- Sensor de agotamiento de oxígeno (ODS): Equipped with a Safety Pilot O.D.S. that automatically shuts down the unit if carbon monoxide or lack of oxygen is detected. Do not tamper with or bypass this safety feature.
- Tipo de gas: This unit operates on either Natural Gas or Liquid Propane. Ensure the correct gas type is used and connections are secure.
- Minimum Firebox Size: Must be installed in a masonry or agency-approved firebox with minimum dimensions of 20 inches H x 28 inches W in front (23 inches W at rear) x 15 inches D.
- Instalación profesional recomendada: While installation can be straightforward, it is highly recommended to seek expert help for gas line connections to ensure safety and compliance with local regulations.
3. Características del producto
- Tecnología de combustible dual: Funciona con gas natural o propano líquido.
- Alta eficiencia: 33,000 BTU output, 99.9% efficient, heating up to 1100 square feet.
- Registros realistas: 8 hand-painted ceramic fiber logs with a stacked red oak appearance.
- Control del termostato: Hace funcionar automáticamente el quemador para mantener la temperatura ambiente deseada.
- Lecho de brasas: U-burner chassis design provides a glowing ember bed for a realistic fire effect.
- Características de seguridad: Includes Oxygen Depletion Sensor (ODS) and Battery-assisted Piezo ignition.
4. Componentes incluidos
The following components are included with your Duluth Forge DLS-30T-2 Fireplace Logs Set:
- Chasis U-Burner (Cantidad: 1)
- Troncos de cerámica pintados a mano (cantidad 8)
- Bag of Embers (Qty. 1)
- 1 pila AAA (para encendido piezoeléctrico)
- Paquete de hardware (cantidad 1)

5. Configuración e instalación
Siga estos pasos para una configuración e instalación adecuadas:
- Prepare Firebox: Ensure your firebox meets the minimum size requirements: 20 inches H x 28 inches W in front (23 inches W at rear) x 15 inches D.
- Conexión de la línea de gas: Connect the gas line to the U-burner chassis. The gas line typically enters from the bottom or side. Professional assistance is recommended for this step.
- Place Chassis: Position the U-burner chassis within the firebox.
- Organizar registros: Carefully arrange the 8 hand-painted ceramic logs on the grate. Refer to the log placement diagram (if provided with packaging) for optimal flame appearance and heat distribution. Ensure the logs do not obstruct the pilot light or burner ports. The logs are designed to fit together like a puzzle.
- Add Embers: Distribute the bag of glowing ember material around the base of the logs and over the burner for a realistic glowing effect.
- Instale la batería: Insert the included AAA battery into the Piezo ignition system.



6. Instrucciones de funcionamiento
To operate your Duluth Forge DLS-30T-2 Fireplace Logs Set:
- Encendido: Use the battery-assisted Piezo ignition to light the pilot. Follow the specific ignition sequence detailed on the appliance or in the full product manual.
- Control del termostato: Once the pilot is lit, use the thermostat control knob to select your desired heat setting. The unit will automatically cycle on and off to maintain the set temperature. There are 5 thermostatic heat settings.
- Apagar: To turn off the unit, rotate the thermostat control knob to the 'OFF' position.

7. Mantenimiento
Regular maintenance ensures optimal performance and longevity of your fireplace logs set:
- Limpieza: Periodically inspect and clean the logs and burner area to remove any dust or debris. Ensure the unit is completely cool before cleaning.
- Inspección de registro: Check ceramic logs for any cracks or damage. Replace damaged logs to maintain proper flame distribution and appearance.
- Luz piloto: Ensure the pilot light is clean and operating correctly. A weak or flickering pilot may indicate a need for cleaning or service.
- Conexiones de gas: Annually inspect all gas connections for leaks using a soap solution.
8. Solución de problemas
If you encounter issues with your fireplace logs set, consider the following:
- Unit Shuts Off Prematurely: If the unit cycles off too soon, ensure the copper thermostat sensor is not too close to the flames. It may need to be adjusted or moved slightly away from direct flame contact. Refer to the full product manual for specific sensor placement guidelines.
- Dificultad para empezar: Check the AAA battery in the Piezo ignition. Ensure gas supply is open and the pilot light is clean.
- No Flame Adjustment: This model typically has a fixed flame height. Flame intensity is generally not adjustable beyond the thermostat settings.
Para problemas persistentes, consulte a un técnico de servicio calificado.
9. Especificaciones
| Característica | Especificación |
|---|---|
| Número de modelo | DLS-30T-2 (Item model number: 210076) |
| Marca | Fragua de Duluth |
| Salida BTU | 33,000 BTU (Maximum) |
| Zona de calentamiento | Hasta 1100 pies cuadrados. |
| Tipo de combustible | Gas natural o propano líquido (combustible dual) |
| Material de registro | Fibra cerámica |
| Log Appearance | Stacked Red Oak (Hand Painted) |
| Dimensiones del producto | 15 x 30 x 20 pulgadas (profundidad x ancho x alto) |
| Peso del artículo | 21 libras |
| Tipo de ignición | Piezo asistido por batería |
| Características de seguridad | Sensor de agotamiento de oxígeno (ODS) |
| Certificaciones | PFS Approved, ANSI Certified System |
10. Garantía y soporte