1. Introducción
This manual provides detailed instructions for the installation, operation, and maintenance of your TOPGREENER TDOS5-JD Dual Load Motion Sensor Switch. This device is designed to automatically control two separate loads, such as lights and a fan, based on occupancy or vacancy detection using Passive Infrared (PIR) technology. Please read this manual thoroughly before installation and use to ensure proper function and safety.
2. Información de seguridad
- ADVERTENCIA: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that the power is off before wiring.
- Installation must be performed by a qualified electrician or in accordance with all local and national electrical codes.
- Este dispositivo requiere un cable de tierra para su correcto funcionamiento.
- Este dispositivo hace not require a neutral wire.
- No utilice este dispositivo con cargas que excedan sus capacidades nominales especificadas.
- Sólo para uso en interiores.
3. Contenido del paquete
- TOPGREENER TDOS5-JD Dual Load Motion Sensor Switch
- Manual de instrucciones
- Tornillos de montaje
- Tuercas de alambre
4. Características del producto
- Control de carga dual: Connect and automate two separate loads (e.g., lights and a fan) from a single unit.
- PIR Sensor de movimiento: Detects motion with a 180° field of view, covering up to 40ft in front and 20ft on either side. Advanced PIR technology helps reduce false triggers.
- Walk-Through Feature: Automatically turns off loads after 2.5 minutes if no further motion is detected within 30 seconds of the initial trigger.
- Múltiples modos de funcionamiento:
- Occupancy Sensor Mode (OCCS): Loads turn ON automatically when motion is detected and OFF after a set time delay when the area is vacant.
- Dual Occupancy Mode (OCCD): Both loads operate in occupancy mode.
- Vacancy Sensor Mode (VACD): Loads are turned ON manually and turn OFF automatically after a set time delay when the area is vacant.
- Retraso de tiempo ajustable: Configurable options for 15 seconds (Test mode), 5 minutes, 10 minutes, 20 minutes, and 30 minutes.
- No se requiere cable neutro: Simplifica la instalación en casas antiguas o ubicaciones sin cable neutro.
- Ground Wire Required: Essential for safe operation.
- Clasificaciones eléctricas: 120/277VAC@60Hz; 800W incandescent/halogen, 150W LED/CFL, 1/4HP motor.
- Cumplimiento: Compliant with Title 20 & Title 24.
- Single-Pole Only: Diseñado para aplicaciones unipolares.
5. Instalación
Antes de comenzar: Ensure power is OFF at the circuit breaker. This device is for single-pole installations only and requires a ground wire.
- Apagar la energía: Localice el disyuntor que controla el interruptor que va a reemplazar y apáguelo. Verifique que la energía esté apagada usando un vol.tage probador.
- Eliminar el interruptor existente: Retire con cuidado la placa de pared y desatornille el interruptor existente de la caja de pared. Desconecte los cables.
- Identificar cables: You should have a Line (hot) wire, two Load wires (one for each load, e.g., light and fan), and a Ground wire. This switch does not require a neutral wire.
- Cablee el interruptor del sensor: Connect the wires from the wall box to the corresponding wires on the TDOS5-JD switch using wire nuts.
- Conectar el Line (hot) wire from the wall box to the switch's Line wire.
- Conectar el Load 1 wire (e.g., for lights) from the wall box to the switch's Load 1 wire.
- Conectar el Load 2 wire (e.g., for fan) from the wall box to the switch's Load 2 wire.
- Conectar el cable a tierra from the wall box to the switch's Ground wire.
- Monte el interruptor: Carefully fold the wires into the wall box and secure the switch with the provided screws. Attach the wall plate.
- Restaurar energía: Vuelva a encender la energía en el disyuntor.
- Warm-Up Period: After installation, allow 1-2 minutes for the device to warm up and calibrate before it functions correctly.

Figura 1: Components of the TDOS5-JD sensor switch, indicating the PIR sensor, Load 1/2 ON/OFF buttons, LED indicator, and a note about the warm-up period after installation. It also highlights that a ground wire is required and no neutral wire is needed.

Figura 2: An image showing the TOPGREENER TDOS5-JD motion sensor switch being carefully inserted into a standard electrical wall box during the installation process.
6. Operación
Once installed and powered, the TDOS5-JD switch will operate according to the selected mode (Occupancy or Vacancy) and configured settings.
- Control automático: In Occupancy modes, the sensor detects motion and automatically turns on the connected loads. After the area becomes vacant for the set time delay, the loads will turn off. In Vacancy mode, loads are turned on manually and turn off automatically.
- ENCENDIDO/APAGADO manual: The switch features two ON/OFF buttons, one for each load, allowing for manual control. Pressing an ON/OFF button will toggle the respective load.
- Indicador LED: A small LED indicator provides visual feedback on the switch's status.

Figura 3: A person carrying a laundry basket walks into a room, and the lights automatically turn on, illustrating the hands-free lighting capability of the motion sensor switch.

Figura 4: A modern bathroom setting where the TOPGREENER dual load sensor switch controls both the overhead lights and the exhaust fan automatically, demonstrating its energy-saving potential.
7. Personalización y configuración
The TDOS5-JD switch offers adjustable settings for time delay, sensitivity (range), and operating mode. These settings are located behind the faceplate.
- Configuración de acceso: Gently pry open the outer cover of the switch to reveal the adjustment dials and mode switch.
- Ajustar el retardo de tiempo: Use a small screwdriver to turn the 'TIME' dial to select the desired delay: Test (15 seconds), 5 minutes, 10 minutes, 20 minutes, or 30 minutes.
- Adjust Sensor Range: Use a small screwdriver to turn the 'RANGE' dial to adjust the motion detection sensitivity from 1 (lowest) to 4 (highest).
- Seleccione el modo de funcionamiento: Use the small switch labeled 'OCCD OCCS VACD' to choose your desired mode:
- OCCD: Dual Occupancy Mode
- OCCS: Single Occupancy Mode
- VACD: Modo vacante

Figura 5: A detailed diagram illustrating the steps to customize the sensor switch settings. It shows how to open the cover, and then adjust the 'Time' dial (Test, 5, 10, 20, 30 Min), 'Range' dial (1-4), and the 'Mode Select' switch (OCCD, OCCS, VACD).

Figura 6: An image depicting a modern bathroom with the sensor switch installed on the wall. A magnified inset shows the adjustable time delay and range dials, emphasizing the customization options for automatic light control.
8. Solución de problemas
| Problema | Posible causa | Solución |
|---|---|---|
| Lights/Fan do not turn ON with motion. | No power; incorrect wiring; sensor blocked; incorrect mode; range too low. | Check circuit breaker. Verify wiring connections. Ensure sensor lens is clear. Confirm correct operating mode (OCCS/OCCD). Increase sensor range. |
| Lights/Fan stay ON too long or turn OFF too quickly. | Incorrect time delay setting; continuous motion detected; walk-through feature activated. | Adjust time delay setting. Ensure no constant motion within sensor's view. Understand walk-through feature behavior. |
| Lights/Fan turn ON without apparent motion (false triggers). | Sensor too sensitive; heat sources or air drafts; sensor facing high-traffic area. | Decrease sensor range. Relocate sensor away from heat sources (HVAC vents, direct sunlight) or drafts. Adjust sensor direction if possible. |
| Timer not functioning as expected (e.g., only extreme settings work). | Dial mechanism issue; specific unit calibration. | Carefully re-adjust the time dial. If issue persists, contact customer support. |
| One load works, but the other does not. | Incorrect wiring for the non-working load; faulty bulb/fan. | Verify wiring connections for Load 1 and Load 2. Test the bulb or fan directly to ensure it is functional. |
9. Especificaciones
- Número de modelo: TDOS5-JD
- Dimensiones: 2.5 x 2.5 x 4.5 pulgadas
- Peso: 6 onzas
- Fuente de energía: Eléctrico con cable
- Volumentage: 120/277 VCA, 60 Hz
- Incandescent/Halogen Load: 800 W máx.
- LED/CFL Load: 150 W máx.
- Clasificación de motores: 1/4HP max
- Área de cobertura: Hasta 1200 pies cuadrados
- Campo de View: 180 grados
- Alcance máximo: 40 feet (in front), 20 feet (sides)
- Temperatura de funcionamiento: 32-131 °F (0-55 °C)
- Alambrado: Ground wire required, no neutral wire required
- Certificaciones: UL Listed, Compliant with Title 20 & Title 24
10. Mantenimiento
The TOPGREENER TDOS5-JD motion sensor switch requires minimal maintenance.
- Limpieza: Periodically wipe the sensor lens and faceplate with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the finish or sensor.
- Inspección: Occasionally check the switch for any visible damage or loose connections. If any issues are found, turn off power at the circuit breaker and address them or consult a qualified electrician.
11. Garantía y soporte
TOPGREENER products are designed for reliability and performance. For specific warranty information, including terms and conditions, please refer to the warranty documentation provided with your purchase or visit the official TOPGREENER website. For technical support or assistance with troubleshooting, please contact TOPGREENER customer service.
Fabricante: MÁS VERDE
Información del contacto: Please visit the TOPGREENER official webSitio para obtener los detalles de contacto y recursos de soporte más actualizados.