FAAC Photobeam Safety Eye XP 30 Instruction Manual

Model: XP 30

1. Producto terminadoview

The FAAC Photobeam Safety Eye XP 30 is a wall-mounted photocell designed for gate opener safety applications. It provides a reliable safety barrier by detecting obstructions in the gate's path, preventing potential accidents.

Key features include a channel selection ability that uses coded signals to prevent interference from other nearby photocells, allowing up to four pairs of XP 30 units to be installed in close proximity without issues. The unit is also protected against interference from external light sources, such as LED headlights, ensuring consistent performance.

This model is suitable for both wall and flush/column-mounted installations with an appropriate adapter.

2. Información de seguridad

Importante: Lea atentamente todas las instrucciones antes de instalar y utilizar el producto. El incumplimiento de estas instrucciones podría provocar lesiones o daños al producto.

  • Este dispositivo es Cumple con UL 325 when used with FAAC Control Boards, ensuring adherence to safety standards for gate operators.
  • Installation and wiring should be performed by qualified personnel in accordance with local electrical codes and regulations.
  • Asegúrese de que la fuente de alimentación esté desconectada antes de realizar cualquier instalación, mantenimiento o solución de problemas.
  • Do not modify the product in any way. Use only original FAAC replacement parts if necessary.
  • Keep the area around the photocells clear of obstructions that could block the beam or interfere with detection.

3. Instalación

The FAAC XP 30 photocell can be installed in a wall-mounted configuration or flush/column-mounted using an adapter (sold separately).

3.1 Mounting the Photocell

  1. Choose a suitable mounting location for both the transmitter (TX) and receiver (RX) units, ensuring they are aligned and have a clear line of sight. The maximum distance between units is 100 ft. (30 m).
  2. Securely mount the photocell units using appropriate fasteners for the chosen surface. The plastic body with a moulded front seal cover and closed-cell cable routing area seal provides protection against environmental elements.
  3. Ensure the units are level and facing each other directly for optimal performance.
FAAC XP 30 Photobeam Safety Eye, front view showing compact design and mounting points.

Figura 1: Frente view of the FAAC XP 30 Photobeam Safety Eye. This image displays the compact design of the photocell unit, highlighting its robust plastic body and potential mounting points. The unit is designed for easy integration into gate opener systems.

3.2 Cableado

  • Connect the power supply (24V) to both the transmitter and receiver units as per the wiring diagram provided with your FAAC control board.
  • The output type is Relay - N.C./N.O. (Normally Closed/Normally Open). Connect the relay output from the receiver to the safety input of your FAAC gate opener control board.
  • Ensure all connections are secure and properly insulated to maintain the IP54 protection class.

3.3 Selección de canales

The XP 30 features 4 Channel Relay Selection. This allows for the installation of up to 4 separate photocell pairs in close proximity without interference. Refer to the specific instructions provided with your FAAC control board for details on setting the channel for each pair.

3.4 Alineación

The XP 30 features Automatic Auto-Alignment with an angle of 7º - 13.5º. After power-up, the units will automatically attempt to align. Ensure a clear line of sight between the TX and RX units. Indicators on the units (refer to the specific product diagram) will confirm successful alignment.

4. Operación

Once properly installed and aligned, the FAAC XP 30 photocells continuously emit and receive an infrared beam. If an object or person breaks this beam while the gate is in motion, the photocells will signal the gate opener control board to stop or reverse the gate's movement, preventing impact.

The coded signals ensure that only the intended transmitter and receiver communicate, minimizing false triggers from other light sources or nearby photocell installations.

5. Mantenimiento

Regular maintenance ensures optimal performance and longevity of your FAAC XP 30 photocells.

  • Limpieza: Periodically clean the lenses of both the transmitter and receiver units with a soft, damp cloth to remove dust, dirt, or debris that may obstruct the beam. Do not use abrasive cleaners.
  • Inspección: Regularly inspect the wiring for any signs of damage, fraying, or loose connections. Ensure the mounting hardware is secure.
  • Prueba de funcionalidad: Periodically test the photocells by intentionally breaking the beam with an object (e.g., a cardboard box) while the gate is closing to ensure it stops or reverses as intended.

6. Solución de problemas

ProblemaPosible causaSolución
Gate does not respond to photocell beam interruption.
  • Misalignment of TX/RX units.
  • Lentes sucias.
  • Wiring issue or no power.
  • Selección de canal incorrecta.
  • Re-align units, ensure clear line of sight.
  • Limpie las lentes con un paño suave.
  • Check power supply (24V) and wiring connections.
  • Verify channel settings on both photocells and control board.
False triggers or intermittent operation.
  • Interferencia de luz externa.
  • Interference from other photocells.
  • Conexiones sueltas.
  • Ensure units are properly shielded from direct sunlight or strong artificial lights.
  • Verify correct channel selection to avoid interference from other XP 30 units.
  • Verifique y asegure todas las conexiones del cableado.
No power indicator on units.
  • No hay suministro de energía.
  • Cableado defectuoso.
  • Check 24V power source.
  • Inspect wiring for breaks or incorrect connections.

If problems persist after attempting these solutions, contact FAAC technical support or a qualified technician.

7. Especificaciones

Distancia máxima100 pies (30 m)
Vol. De la fuente de alimentacióntage24 V
Absorbed Current (RX)30 mA
Absorbed Current (TX)20 mA
Calificaciones de contacto60 VA / 24 W
AlineaciónAutomatic Auto-Alignment
Auto-Alignment Angle7º - 13.5º
Tipo de salidaRelay - N.C./N.O.
Clase de protecciónIP54
Temperaturas de funcionamiento-4°F ~ 131°F (-20°C ~ 55°C)
Dimensiones (LxHxD)2.16" x 3" x 0.82" (55 mm x 76 mm x 21 mm)
CumplimientoUL 325 Compliant (when used with FAAC Control Boards)

8. Garantía y soporte

For warranty information, please refer to the documentation provided with your purchase or contact FAAC directly. Technical support is available through FAAC's official channels for assistance with installation, operation, or troubleshooting.

Visita la página oficial de FAAC webSitio para obtener los últimos recursos de soporte e información de contacto.

© 2024 FAAC. Todos los derechos reservados. Información sujeta a cambios sin previo aviso.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.