Lúmenes VC-A50PN

Lumens VC-A50PN NDI, SDI, HDMI 20x HD PTZ Camera User Manual

Modelo: VC-A50PN

1. Introducción

The Lumens VC-A50PN is a high-definition Pan/Tilt/Zoom (PTZ) camera designed for professional video production and streaming applications. It features a 1/2.8-inch image sensor, delivering Full HD 1080p video at 60 frames per second. This camera supports multiple output interfaces including NDI, 3G-SDI, and HDMI, offering versatile connectivity options. Power over Ethernet (PoE+) simplifies installation by providing power, control, and video over a single Ethernet cable. The VC-A50PN is equipped with a 20x optical zoom lens, ensuring clear images even in challenging lighting conditions. Its precise and quiet PTZ mechanism allows for wide shooting angles and smooth camera movements, making it suitable for education, videoconferencing, live broadcasting, and gaming environments.

Lumens VC-A50PN PTZ Camera front view

Figura 1: Frente y lateral view of the Lumens VC-A50PN PTZ Camera. This image shows the camera's compact design and lens.

2. Información de seguridad

Please read all instructions carefully before operating the camera. Retain this manual for future reference.

  • Fuente de energía: Use only the specified power adapter (DC 12V) or a compliant PoE+ (IEEE 802.3at) network switch.
  • Instalación: Install the camera on a stable surface or mount it securely to a ceiling using appropriate hardware. Ensure proper ventilation around the camera.
  • Ambiente: Avoid exposing the camera to moisture, rain, dust, or extreme temperatures. Do not operate near heat sources.
  • Limpieza: Desconecte la alimentación antes de limpiar. Utilice un paño suave y seco. No utilice limpiadores líquidos ni en aerosol.
  • Servicio: No intente reparar este producto usted mismo. Refiera todo el servicio a personal de servicio calificado.
  • cables: Ensure all cables are properly connected and secured to prevent accidental disconnection or damage.

3. Contenido del paquete

Verifique que todos los artículos enumerados a continuación estén incluidos en su paquete. Si falta algún artículo o está dañado, comuníquese con su distribuidor de inmediato.

  • Lumens VC-A50PN PTZ Camera
  • Adaptador de corriente (DC 12V)
  • Control remoto por infrarrojos
  • Mounting Bracket (for ceiling installation)
  • Manual de usuario (este documento)

4. Producto terminadoview

4.1 Funciones de la cámara

  • Full HD 1080p output at 60 fps
  • Lente con zoom óptico de 20x
  • NDI|HX Technology for low-latency IP video transmission
  • Supports Power over Ethernet (PoE+)
  • Multiple video outputs: HDMI, 3G-SDI, and IP (Ethernet)
  • Wide shooting angles with 340° pan and 120° tilt range
  • Supports SRT (Secure Reliable Transport) protocol
  • Audio input supports AAC encoding with 44.1/48 K sampfrecuencia de ling

4.2 Conexiones del panel posterior

The rear panel of the VC-A50PN camera provides all necessary input and output ports for power, video, audio, and control. Refer to the diagram below for a detailed layout.

Lumens VC-A50PN Rear Panel Connections

Figura 2: detallada view of the Lumens VC-A50PN rear panel connections.

  1. Kensington Lock Port: For securing the camera with a compatible lock.
  2. DC EN 12V: Entrada de alimentación para el adaptador de corriente CC 12 V incluido.
  3. USB: For firmware updates and service.
  4. AUDIO EN: 3.5mm stereo audio input jack.
  5. ETHERNET (NDI|HX): RJ-45 port for network connection, PoE+ power, NDI video, and IP control.
  6. SALIDA RS-232: 8-pin mini-DIN connector for RS-232 serial control output.
  7. RS-232 ENTRADA: 8-pin mini-DIN connector for RS-232 serial control input.
  8. SALIDA HDMI: HDMI output port for video.
  9. RS-422: 9-pin terminal block for RS-422 serial control.
  10. 3G-SDI: BNC connector for 3G-SDI video output.
  11. OUTPUT SWITCH (DIP Switches): Four DIP switches to configure video output settings. Refer to section 5.3 for details.
  12. IR SELECT: Switch to select the IR remote control address.

5. Configuración

5.1 Instalación física

The VC-A50PN can be installed on a desktop or mounted to a ceiling.

  • Instalación de escritorio: Place the camera on a flat, stable surface. Ensure adequate space for ventilation and cable connections.
  • Instalación de techo: Use the provided mounting bracket and hardware. Ensure the ceiling can support the camera's weight. Follow the instructions included with the mounting kit for secure installation.

5.2 Cables de conexión

Before connecting cables, ensure the camera is powered off.

  1. Conexión de energía:
    • Energía DC: Connect the included 12V DC power adapter to the "DC IN 12V" port.
    • Alimentación PoE+: If using PoE+, connect an Ethernet cable from a PoE+ enabled network switch to the "ETHERNET" port. The camera will receive power through this connection, eliminating the need for the DC power adapter.
  2. Salida de vídeo:
    • HDMI: Connect an HDMI cable from the "HDMI OUT" port to an HDMI input device (e.g., monitor, switcher).
    • 3G-SDI: Connect a 3G-SDI cable from the "3G-SDI" port to an SDI input device.
    • IP (NDI|HX): Connect an Ethernet cable from the "ETHERNET" port to your network. The NDI|HX video stream will be available over the network.
  3. Entrada de audio: Connect an audio source (e.g., microphone, mixer) to the "AUDIO IN" 3.5mm jack.
  4. Conexiones de control:
    • RS-232: Connect a serial control cable to the "RS-232 IN" port for external control. The "RS-232 OUT" port can be used for daisy-chaining.
    • RS-422: Connect a serial control cable to the "RS-422" terminal block for external control.
    • Control de PI: The camera can also be controlled via IP commands over the Ethernet connection.

5.3 Output Switch (DIP Switches) Configuration

The four DIP switches on the rear panel (labeled "OUTPUT SWITCH") are used to configure specific video output settings. Refer to the table below for common configurations. Ensure the camera is powered off before changing DIP switch settings.

Lumens VC-A50PN I/O Connections Diagram with DIP switches

Figure 3: I/O Connections Diagram highlighting the OUTPUT SWITCH DIP switches.

Interruptor 1Interruptor 2Interruptor 3Interruptor 4Función/Configuración
APAGADOAPAGADOAPAGADOAPAGADODefault (e.g., 1080p/60)
ONAPAGADOAPAGADOAPAGADO1080p/59.94
APAGADOONAPAGADOAPAGADO1080p/50
ONONAPAGADOAPAGADO1080i / 60
APAGADOAPAGADOONAPAGADO720p/60
............(Consult full manual for all DIP switch combinations)

6. Instrucciones de funcionamiento

6.1 Encendido / Apagado

  • Encendido: Connect the power adapter or PoE+ Ethernet cable. The camera will initiate its startup sequence.
  • Apagado: Disconnect the power adapter or PoE+ Ethernet cable.

6.2 Control PTZ

The camera can be controlled via the IR remote control, RS-232/RS-422 serial commands, or IP control software.

  • Panorámica/inclinación: Use the directional controls on your remote or software to move the camera horizontally (pan) and vertically (tilt). The camera offers 340° pan and 120° tilt.
  • Zoom: Use the zoom controls to adjust the 20x optical zoom.
  • Enfocar: The camera supports auto-focus. Manual focus adjustment may be available via control software.
  • Presets: The camera supports up to 128 preset positions. You can save and recall specific pan, tilt, and zoom settings for quick camera positioning.

6.3 salidas de video

The VC-A50PN simultaneously outputs video via HDMI, 3G-SDI, and IP (NDI|HX).

  • HDMI/3G-SDI: Connect these outputs to your video switcher, monitor, or recording device. The resolution and frame rate are determined by the DIP switch settings and camera configuration.
  • NDI|HX: Once connected to a network, the NDI|HX stream will be discoverable by NDI-compatible software and hardware on the same network.

6.4 Network Configuration (IP Control & NDI)

For IP control and NDI functionality, the camera needs to be connected to a network. The camera typically obtains an IP address via DHCP by default. You can access the camera's web interfaz ingresando su dirección IP en un web browser for advanced settings, including static IP configuration, NDI settings, and image adjustments.

  • Finding the IP Address: Use a network scanner tool or the camera's OSD (On-Screen Display) menu (if available via HDMI/SDI output) to find the camera's current IP address.
  • Web Interfaz: Abrir una web browser and enter the camera's IP address to access its configuration page.
  • NDI Discovery: NDI-enabled applications (e.g., OBS, vMix, Wirecast) will automatically detect the VC-A50PN on the network.

7. Mantenimiento

7.1 Limpieza de la cámara

Asegúrese de que la cámara esté apagada y desconectada de todas las fuentes de alimentación antes de limpiarla.

  • Cuerpo de cámara: Use a soft, dry cloth to wipe the camera body. Do not use abrasive cleaners, waxes, or solvents.
  • Lente: Gently clean the lens with a lens cleaning cloth and a specialized lens cleaning solution. Avoid touching the lens surface with your fingers.

7.2 actualizaciones de firmware

Periodically check the Lumens official website for available firmware updates. Firmware updates can improve performance, add new features, or fix bugs. Follow the instructions provided with the firmware update package carefully.

8. Solución de problemas

If you encounter issues with your VC-A50PN camera, refer to the following common problems and solutions:

ProblemaPosible causaSolución
Sin poderAdaptador de corriente no conectado; PoE+ no activo o cable defectuoso.Ensure power adapter is securely connected and outlet is live. If using PoE+, verify the network switch port is PoE+ enabled and the Ethernet cable is functional.
Sin salida de vídeo (HDMI/SDI)Incorrect cable connection; wrong DIP switch settings; display input not selected.Check HDMI/SDI cable connections. Verify DIP switch settings match desired output resolution/frame rate. Ensure your display/switcher is set to the correct input.
No NDI stream detectedNetwork issue; camera not powered; firewall blocking NDI.Ensure camera is powered and connected to the network. Verify the camera has an IP address. Check network firewall settings on your computer/network. Ensure NDI is enabled in the camera's web interfaz.
El control PTZ no respondeIR remote battery low; incorrect control cable; wrong control protocol selected.Replace IR remote batteries. Check RS-232/RS-422 cable connections. Verify the control software/device is configured for the correct protocol (VISCA, PELCO D/P, NDI).
Image quality issues (blurry, dark, overexposed)Lens dirty; incorrect exposure/white balance settings.Clean the lens. Adjust exposure, white balance, and gain settings via the camera's web interfaz o software de control.

If the problem persists after trying these solutions, please contact Lumens technical support.

9. Especificaciones

Below are the detailed technical specifications for the Lumens VC-A50PN PTZ Camera.

CaracterísticaDetalle
Nombre del modeloVC-A50PN
Sensor de imagenCMOS de 1/2.8" y 2 MP
Resolución de salida de video1080p (60/59.94/50/30/29.97/25 fps), 1080i (60/59.94/50 fps), 720p (60/59.94/50 fps)
Zoom óptico20x
Rango de movimiento horizontal y verticalPan: -170° to +170° (Total 340°); Tilt: -30° to +90° (Total 120°)
Interfaces de salida de vídeoHDMI, 3G-SDI, Ethernet (NDI|HX)
Compresión de vídeoMJPEG, H.264 / SVC
Fuente de poderDC 12V or PoE+ (IEEE 802.3at)
Interfaces de controlRS-232, RS-422, Ethernet (IP Control)
Protocolo de ControlVISCA, PELCO D/P, NDI
Iluminación mínima1.0 Lux (F1.6, 50IRE, 30fps)
Velocidad de obturación1/1 ~ 1/10,000 seg
Longitud focalf = 4.7 ~ 94 mm
Dimensiones (An x Al x Pr)174 x 186 x 187mm (6.9 x 7.3 x 7.3 pulgadas)
Peso2 kg (4.4 libras)
ColorBlanco
Temperatura de funcionamiento0 °C a 40 °C (32 °F a 104 °F)

10. Garantía y soporte

10.1 Información de garantía

Lumens products are designed for reliability and performance. For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Lumens webSitio. La garantía generalmente cubre defectos de materiales y mano de obra en condiciones normales de uso durante un período específico a partir de la fecha de compra.

10.2 Soporte técnico

If you require technical assistance or have questions regarding the operation or maintenance of your Lumens VC-A50PN camera, please contact Lumens technical support. Before contacting support, please have your product model number (VC-A50PN) and serial number ready. You can find contact information on the official Lumens websitio.

  • Recursos en línea: Visit the Lumens website for FAQs, drivers, firmware updates, and additional documentation.
  • Información del contacto: Refer to the Lumens website for phone numbers, email addresses, and support hours for your region.

© 2023 Lumens. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.