The Jectse Timer Soft Starter is a versatile delay relay motor starter designed for efficient motor start control. It features adjustable delay ranges and wide working voltage compatibility, making it suitable for various industrial and scientific applications.

Figura 1: Frente view of the Jectse Timer Soft Starter, showing the control knobs and indicator lights.
2. Características principales
- Adjustable Start Delay (T1): Range from 0.1 seconds to 10 minutes, set via knob.
- Adjustable Conversion Time (T2): Range from 0.1 seconds to 1 second, set via knob.
- Amplio volumen de trabajotage: Supports AC/DC 12V to 240V.
- Indicadores LED: Clearly shows the working status of the relay.
- Diseño compacto: Super small size, only 18mm wide, designed for 35mm rail mounting.

Figure 2: The soft starter unit highlighting its compact size and adjustable settings.
3. Información de seguridad
Lea y comprenda todas las instrucciones de seguridad antes de instalar o utilizar este dispositivo. El incumplimiento de estas instrucciones podría provocar una descarga eléctrica, un incendio o lesiones graves.
- Ensure power is disconnected before any installation or wiring.
- La instalación solo debe ser realizada por personal calificado.
- Verifique el vol. correctotage and current ratings before connecting to a power source.
- No exponga el dispositivo a la humedad ni a temperaturas extremas.
- Asegúrese de que haya una conexión a tierra adecuada cuando sea necesario.
4. Contenido del paquete
El paquete incluye:
- 1 x Jectse Timer Soft Starter
5. Configuración e instalación
The Jectse Timer Soft Starter is designed for 35mm DIN rail mounting. Follow these steps for proper installation:
- Ensure all power to the circuit is turned off at the main breaker.
- Mount the soft starter securely onto a standard 35mm DIN rail. The red clips on the side facilitate easy mounting and removal.
- Connect the power supply to terminals A1 and A2. The device supports AC/DC 12-240V.
- Connect the motor control wiring to the output terminals (15, 16, 18, 25, 26, 28) as per your application's wiring diagram. Refer to the diagram on the side of the unit for specific connections.
- Ensure all wiring connections are secure and meet the specified wiring capacity (1x2.5mm² or 2x 1.5mm²).
- Verifique nuevamente todas las conexiones antes de restablecer la energía.

Figura 3: Primer plano view of the wiring terminals and the integrated wiring diagram on the unit.

Figura 4: Lado view illustrating the red clips for DIN rail mounting.
6. Instrucciones de funcionamiento
Once installed and powered, the Timer Soft Starter operates based on its configured delay settings.
- Setting Start Delay (T1): Use the knob labeled 'T1' to adjust the initial start delay from 0.1 seconds to 10 minutes. This delay determines how long the soft starter waits before initiating the motor start sequence.
- Setting Conversion Time (T2): Use the knob labeled 'T2' to set the conversion time from 0.1 seconds to 1 second. This time is crucial for the smooth transition during the motor's soft start phase.
- Indicadores LED:
- A green LED indicates the power status (Un).
- A red LED indicates the relay's working status (R).
Vídeo 1: Un finalview of the Jectse Timer Soft Starter, demonstrating its features and appearance.
7. Mantenimiento
The Jectse Timer Soft Starter is designed for long-term reliability with minimal maintenance. However, regular checks can ensure optimal performance:
- Inspeccione periódicamente las conexiones del cableado para comprobar que estén bien ajustadas y que no presenten signos de desgaste o corrosión.
- Mantenga la unidad limpia y libre de polvo y residuos. Utilice un paño seco y suave para limpiarla.
- Asegúrese de que el entorno operativo permanezca dentro de los rangos de temperatura y humedad especificados.
- No intente abrir ni reparar la unidad usted mismo. Consulte a personal de servicio técnico cualificado.
8. Solución de problemas
If you encounter issues with your Timer Soft Starter, consider the following common problems and solutions:
| Problema | Posible causa | Solución |
|---|---|---|
| Unit not powering on (Green LED off) | No power supply; Incorrect wiring; Faulty unit. | Check power source; Verify A1/A2 wiring; Contact support if power is present and wired correctly. |
| Motor not starting after delay | Incorrect output wiring; Relay not activating; Motor issue. | Check output terminals (15, 16, 18, 25, 26, 28) connections; Observe red LED for relay status; Test motor independently. |
| Delay times are inaccurate | Knob settings incorrect; Environmental factors. | Re-adjust T1 and T2 knobs carefully; Ensure stable operating environment. |
If the problem persists after attempting these solutions, please contact Jectse customer support.
9. Especificaciones
| Parámetro | Valor |
|---|---|
| Tipo | CA/CC 12 V ~ 240 V |
| Rated Control Power Supply Voltage | CA/CC 12-240 V (50/60 Hz) |
| Consumo de energía | CA 0.7-3 VA / CC 0.5-1.7 W |
| Starting Delay (T1) | 0.1s - 10min |
| Conversion Delay (T2) | 0.1 s - 1 s |
| Ajuste de precisión | 5% |
| Precisión de repetición | 0.2% |
| Producción | Two sets of conversion contacts 16A/AC250VAC |
| Minimum Switching Power | 500 mW |
| Vida mecánica | 1 x 10,000,000 ciclos |
| Electrical Life (Load) | 1,000,000 ciclos |
| Tiempo de reinicio | 200ms máximo |
| Temperatura del entorno de trabajo | -20°C ~ 55°C |
| Temperatura de almacenamiento y transporte | -35°C ~ 75°C |
| Instalación | Montaje en riel de 35 mm |
| Nivel de protección | IP20 |
| Altitud de instalación | 2000 metros |
| Nivel de contaminación | 2 |
| Capacidad de cableado | 1x2.5mm² or 2x 1.5mm² |
| Dimensiones | 90 x 18 x 64 mm (3.5 x 0.7 x 2.5 pulgadas) |
| Conforme a la norma | GB14048.5.IEC/EN 60255-1 |
| Peso | Aprox. 96 g (3.4 onzas) |
10. Garantía y soporte
For warranty information or technical support, please contact Jectse customer service. Keep your purchase receipt for any warranty claims.
Fabricante: Inyección
Número de modelo: Jectseh4tnewb30y-03
Fecha de primera disponibilidad: 4 de mayo de 2019
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.