UMLIFE XH-W3001

UMLIFE XH-W3001 Mini Thermostat Switch Instruction Manual

Model: XH-W3001 (220V)

1. Introducción

The UMLIFE XH-W3001 is a digital LED temperature controller module designed for precise temperature management. It features a waterproof sensor probe and supports both heating and cooling modes, making it suitable for various applications such as incubation, equipment cases, and air conditioning systems. This manual provides detailed instructions for the safe and effective use of your XH-W3001 thermostat.

2. Información de seguridad

  • Asegúrese de que la fuente de alimentación voltage matches the device's rated voltage (220 V).
  • Todo el cableado debe ser realizado por una persona calificada para evitar descargas eléctricas o daños.
  • No exponga el dispositivo a humedad excesiva ni a temperaturas extremas fuera de su rango de funcionamiento.
  • Mantenga el dispositivo alejado de materiales inflamables.
  • Desconecte la alimentación antes de realizar cualquier cableado o mantenimiento.

3. Producto terminadoview

The XH-W3001 features a clear digital LED display for current temperature readings and control settings. It includes two buttons for easy parameter adjustment and an indicator light to show output status.

UMLIFE XH-W3001 Mini Thermostat Switch, front view con pantalla LED y botones de control.

Figura 3.1: Frente view of the XH-W3001 Thermostat.

Diagram showing labeled components of the XH-W3001 thermostat: Temperature LED Display, Indicator, Up Button, Down Button, Model Number.

Figure 3.2: Labeled components of the XH-W3001 Thermostat.

Características principales:

  • Luz indicadora LED: Displays the current output status.
  • Digital Display Tube: Shows measuring temperature with high accuracy (0.1℃ precision).
  • Dos modos de trabajo: Heating (start temperature < stop temperature) and Cooling (start temperature > stop temperature).
  • Amplio rango de temperatura: -50℃ to 110℃.
  • Construcción duradera: ABS flame retardant housing.
  • Sonda impermeable: 1-meter NTC10K stainless steel probe.

4. Especificaciones

CaracterísticaEspecificación
ModeloXH-W3001
Volumentage220V (also suitable for 110V)
Rango de temperatura-50℃ a 110℃
Precisión del control de temperatura0.1℃
Tipo de pantallaCONDUJO
Tipo de sondaNTC10K (1 meter, waterproof)
MaterialABS (Acrylonitrile Butadiene Styrene), Stainless Steel
Componentes incluidos1pcs Temperature Controller

5. Configuración y cableado

Proper wiring is crucial for the safe and correct operation of the XH-W3001. Refer to the diagram below and follow the instructions carefully.

Wiring diagram for the 220V XH-W3001 Temperature Controller, showing connections for 220V power supply, 220V direct output (e.g., to a light bulb), and sensor probe.

Figure 5.1: XH-W3001 220V Wiring Connection Diagram.

Instrucciones de cableado:

  1. Entrada de energía (220 V): Connect the two wires from your 220V AC power supply to the terminals labeled 'N' (Neutral) and 'L' (Live) on the controller. These are typically the two leftmost terminals.
  2. Load Output (220V): Connect the device you wish to control (e.g., a heater or fan) to the output terminals. One wire from the load connects to the 'N' terminal (Neutral) of the output, and the other wire connects to the 'L' terminal (Live) of the output. Ensure the load's voltage matches the controller's output.
  3. Sonda del sensor: Plug the waterproof NTC10K temperature sensor probe into the dedicated two-pin connector on the controller. The probe can be placed in the environment where temperature needs to be measured.
  4. Toma de tierra: If applicable, ensure proper grounding for your power supply and load according to local electrical codes.

Warning: Always ensure power is disconnected before making any wiring connections to prevent electrical shock.

6. Instrucciones de funcionamiento

Encendido inicial:

After correct wiring, apply power to the controller. The LED display will show the current measured temperature. The red indicator light will illuminate when the output is active.

Configuración de parámetros de temperatura:

The XH-W3001 has two main parameters: Start Temperature (P0) and Stop Temperature (P1).

  • Set Start Temperature (P0):
    Mantenga pulsado el UP button for approximately 3 seconds. The display will flash. Use the UP or ABAJO buttons to adjust the desired start temperature. Press the UP button again to confirm and exit, or wait 5 seconds for automatic exit.
  • Set Stop Temperature (P1):
    Mantenga pulsado el ABAJO button for approximately 3 seconds. The display will flash. Use the UP or ABAJO buttons to adjust the desired stop temperature. Press the ABAJO button again to confirm and exit, or wait 5 seconds for automatic exit.

Working Modes (Heating/Cooling):

  • Modo de calefacción: Si el Start Temperature (P0) Esta establecido más bajo que el Stop Temperature (P1), the controller operates in heating mode. The output will activate when the current temperature drops below P0 and deactivate when it reaches P1.
  • Modo de enfriamiento: Si el Start Temperature (P0) Esta establecido más alto que el Stop Temperature (P1), the controller operates in cooling mode. The output will activate when the current temperature rises above P0 and deactivate when it reaches P1.

Configuración avanzada:

To access advanced settings, press and hold both UP y ABAJO buttons simultaneously for approximately 3 seconds. The display will show 'P0'. Use the UP or ABAJO buttons to cycle through the parameters (P0-P6). Press the UP button to enter the selected parameter's adjustment mode, then use UP or ABAJO Para cambiar su valor, presione UP again to save and exit the parameter, or wait 5 seconds for automatic exit.

  • P0: Heating/Cooling Mode (Set Start Temp) - (As described above, this is the primary start temperature setting)
  • P1: Stop Temperature (Set Stop Temp) - (As described above, this is the primary stop temperature setting)
  • P2: Temperature Correction: Adjusts the measured temperature by a certain offset (e.g., to calibrate the sensor). Range: -10.0℃ to 10.0℃.
  • P3: Delay Start: Sets a delay time (in minutes) before the output activates after the temperature condition is met. Range: 0 to 10 minutes.
  • P4: High Temperature Alarm: Sets a temperature threshold. If the current temperature exceeds this value, an alarm may be triggered (visual or audible, depending on implementation).
  • P5: Low Temperature Alarm: Sets a temperature threshold. If the current temperature falls below this value, an alarm may be triggered.
  • P6: Data Lock: Locks the settings to prevent accidental changes.

Restablecer la configuración de fábrica:

To restore all settings to their factory defaults, power off the controller. Then, press and hold both the UP y ABAJO buttons simultaneously while powering the device back on. The display will show '888' indicating a successful reset.

7. Mantenimiento

  • Limpieza: Gently wipe the device's exterior with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • Cuidado de la sonda: Ensure the sensor probe is clean and free from debris for accurate readings. The stainless steel probe is waterproof, but avoid unnecessary physical damage.
  • Conexiones: Revise periódicamente todas las conexiones del cableado para asegurarse de que estén seguras y libres de corrosión.

8. Solución de problemas

  • La pantalla está en blanco:
    Check power connections. Ensure the voltage supply is correct (220V).
  • La lectura de temperatura es inexacta:
    Verify the sensor probe is correctly connected and placed in the desired measurement area. Use the P2 (Temperature Correction) setting to calibrate if necessary.
  • Controller not switching output:
    Check if the Start (P0) and Stop (P1) temperatures are set correctly for the desired heating or cooling mode. Ensure the load is properly wired and functional. Check if P3 (Delay Start) is active.
  • Settings cannot be changed:
    Check if P6 (Data Lock) is enabled. Disable it to adjust settings.

9. Garantía y soporte

This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the product packaging or contact the retailer where the product was purchased.

For technical support, troubleshooting assistance, or inquiries regarding product operation, please contact UMLIFE customer service through the retailer's platform or the official UMLIFE websitio.

Ask a question about this manual