Franklin 2145079004S

Manual de instrucciones del motor de bomba sumergible para pozo profundo Franklin de 3/4 HP

Model: 2145079004S | Brand: Franklin

1. Introducción

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Franklin 3/4 HP Deep Well Submersible Pump Motor, Model 2145079004S. Please read these instructions thoroughly before installation or operation to ensure proper function and longevity of the product.

Franklin 3/4 HP Deep Well Submersible Pump Motor

Image 1.1: Franklin 3/4 HP Deep Well Submersible Pump Motor. This image displays the cylindrical motor unit, primarily stainless steel, with electrical connection points and a splined shaft visible at the top.

2. Información de seguridad

Observe siempre las precauciones básicas de seguridad para reducir el riesgo de incendio, descarga eléctrica y lesiones personales. El incumplimiento de estas instrucciones puede provocar lesiones graves o la muerte.

  • Seguridad eléctrica: Ensure all electrical connections are made by a qualified electrician and comply with local codes. Disconnect power before servicing.
  • Toma de tierra: The motor must be properly grounded to prevent electric shock.
  • Calidad del agua: Do not use this pump for flammable liquids or in hazardous locations.
  • Levantamiento: Use appropriate lifting equipment when handling the pump motor due to its weight.
  • Temperatura: Do not operate the motor in ambient temperatures exceeding 86°F (30°C).

3. Configuración e instalación

Proper installation is crucial for the performance and longevity of your submersible pump motor. Consult a professional for installation if you are unsure about any steps.

  1. Verificación previa a la instalación: Verifique que las especificaciones del motor (volumentage, HP, phase) match your power supply and pump requirements. Inspect the motor for any shipping damage.
  2. Motor-Pump Assembly: Carefully align and attach the motor to the pump end, ensuring the splined shaft engages correctly. Secure all fasteners according to the pump manufacturer's recommendations.
  3. Conexiones eléctricas: Connect the motor leads (3 wires) to the control box or power supply. Ensure all connections are watertight and insulated using appropriate splicing kits for submersible applications.
  4. Toma de tierra: Connect the motor's ground wire to a reliable earth ground.
  5. Bajando al pozo: Use a strong, non-corrosive safety rope or cable attached to the pump assembly. Carefully lower the pump and motor into the well, ensuring it hangs freely and does not touch the well casing.
  6. Conexión de tubería: Connect the discharge pipe to the pump outlet. Ensure all pipe connections are secure and leak-free.

4. Operación

Una vez instalado, el motor está diseñado para un funcionamiento continuo dentro de sus parámetros especificados.

  • Puesta en marcha inicial: After installation, prime the pump if necessary (refer to pump manual). Restore power to the system. The motor should start smoothly.
  • Escucha: Observe the system for unusual noises, vibrations, or leaks during initial operation.
  • Nivel del agua: Ensure the well water level remains above the pump intake during operation to prevent dry running, which can damage the motor.
  • Protección térmica: The motor features automatic thermal protection. If the motor overheats, it will shut off and restart once it cools down. Investigate the cause of overheating if this occurs frequently.

5. Mantenimiento

The Franklin submersible pump motor is designed for minimal maintenance. However, periodic checks of the overall pumping system are recommended.

  • Revisión anual del sistema: Have a qualified technician inspect the entire well system annually, including the pump, motor, control box, and pressure tank.
  • Conexiones eléctricas: Periodically check for loose or corroded electrical connections in the control box.
  • Calidad del agua: Monitor water quality for excessive sediment or abrasive particles, which can reduce pump and motor life.
  • Carcasa del motor: The corrosion-resistant stainless steel shell requires no specific maintenance.

6. Solución de problemas

Refer to the following table for common issues and their potential solutions. Always disconnect power before attempting any troubleshooting or repairs.

ProblemaPosible causaSolución
El motor no arrancaNo power; tripped breaker; faulty control box; wiring issue.Check power supply, reset breaker, inspect control box components, verify wiring connections.
El motor funciona pero no hay agua.Low well water level; clogged pump intake; faulty pump end; air lock.Check well level, inspect pump intake, consult pump manual, bleed air from system.
Motor cycles frequentlyPressure tank issue; leaky plumbing; low well yield.Inspect pressure tank, check for leaks, assess well capacity.
El motor se sobrecalienta y se apaga.Vol bajotage; excessive load; insufficient cooling flow; dry running.Verificar voltage, reduce load if possible, ensure proper water flow around motor, check well level.

7. Especificaciones técnicas

Detailed specifications for the Franklin 3/4 HP Deep Well Submersible Pump Motor, Model 2145079004S.

EspecificaciónValor
ArtículoDeep Well Submersible Pump Motor
Motor ApplicationZapatillas
Motor Sub ApplicationBombas sumergibles para pozos profundos
Tipo de motorCapacitor-Start
RecintoTotally Enclosed Nonventilated
Caballos de fuerza (HP)3/4
RPM de la placa de identificación3450
Volumentage230 V
Fase1
Carga completa Amps6.8 A
Max. Service Factor Amps8.0 A
Frecuencia (Hz)60 Hz
Factor de servicio1.5
Max. Temperatura ambiente86 °F (30 °C)
Thrust Rating300 libras.
Numero de alambres3
Protección térmicaAuto
RotaciónCCWSE (Counter-Clockwise Shaft End)
Diámetro4 pulgadas
Tipo de diafragmaPressure Equalizing
Material del ejeSplined Stainless Steel
Material de la carcasaCorrosion Resistant Stainless Steel
Tipo de estatorSellado herméticamente
Longitud del cable48 pulgadas
Altura10-5/8 pulgadas
Rango de RPM3001-3600
Número de pieza2145079004S
ASINB096BFMDN2
Fecha de primera disponibilidad1 de junio de 2021

8. Garantía y atención al cliente

For warranty information, please refer to the documentation provided at the time of purchase or contact your authorized Franklin dealer. Keep your purchase receipt as proof of purchase.

For technical assistance or customer support, please contact your product supplier or an authorized service center. When contacting support, please have your model number (2145079004S) and purchase date readily available.

© 2023 Franklin Electric. Todos los derechos reservados.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.