T.I.P. Maxima 350 IPX DUO 30274
T.I.P. Maxima 350 IPX DUO 30274 Dirty Water Pump Instruction Manual
Model: Maxima 350 IPX DUO 30274 | Brand: T.I.P.
1. Introducción
The T.I.P. Maxima 350 IPX DUO is a powerful and versatile combination submersible pump designed for various water drainage tasks. Its extendable pump base allows for quick conversion between a high-performance dirty water pump and a clean water pump with ultra-flat suction. This manual provides essential information for safe and efficient operation, setup, and maintenance of your pump.

Image: The T.I.P. Maxima 350 IPX DUO pump, showcasing su diseño robusto y sus componentes.
2. Instrucciones de seguridad
Please read and understand all safety instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.
- Desconecte siempre la bomba de la fuente de alimentación antes de realizar cualquier mantenimiento o limpieza.
- Ensure the power cable and plug are in perfect condition. Do not use if damaged.
- The pump is designed for pumping water only. Do not use it for flammable, corrosive, or explosive liquids.
- Do not operate the pump in swimming pools or areas where people are in the water.
- Mantenga a los niños y a las personas no autorizadas lejos del área de operación.
- Asegúrese de que haya una ventilación adecuada cuando trabaje en espacios cerrados.
- The maximum liquid temperature for operation is 35 °C.
3. Contenido del paquete
Verifique que todos los artículos estén presentes en el paquete:
- T.I.P. Maxima 350 IPX DUO Submersible Pump with connection cable
- Connection elbow with union nut
- Multi-dimensional connection piece
- Manual de instrucciones
4. Configuración
4.1 Conexión de la manguera de descarga
The pump features a 47.80 mm (1.5 inch external thread) pressure connection. Use the provided connection elbow and multi-dimensional connection piece to attach your discharge hose.
- Opción 1: Hose with Ø 40 mm. Secure with a hose clamp.
- Opción 2: Hose with 1 1/4" internal thread. Remove the upper part of the connector.
- Opción 3: Hose with Ø 32 mm. Secure with a hose clamp.
- Opción 4: Hose with 1" internal thread. Remove the upper part of the connector.
- Opción 5: Hose with 1 1/2" internal thread. Use the supplied connection elbow.

Image: Diagram showing various hose connection options and sizes for the pump.

Image: The supplied connection elbow for attaching a 1 1/2" internal thread hose.
An optional C-Storz coupling can also be used for the discharge hose (not included).
4.2 Adjusting the Pump Base for Water Type
The Maxima 350 IPX DUO features an extendable pump base to switch between dirty water and clean water modes.
- Modo agua sucia: For water with particle sizes up to 30 mm. The pump base is extended, allowing for a residual water level of 35 mm.
- Clean Water Mode (Flat Suction): For clear water with particle sizes up to 1 mm. The pump base is retracted, enabling an ultra-flat suction down to 1 mm residual water level.

Image: The T.I.P. Maxima 350 IPX DUO pump, highlighting its extendable pump base for different water types.

Image: The pump operating in dirty water, showing the water level at 125 mm for activation.

Image: The pump after draining dirty water, showing a residual water level of 35 mm.

Image: The pump operating in clean water, showing the water level at 100 mm for activation.

Image: The pump after draining clean water, showing an ultra-flat residual water level of 1 mm.

Image: Illustration of the maximum particle sizes the pump can handle: 1 mm for clear water and 30 mm for dirty water.
4.3 Ajuste del interruptor de flotador
The pump is equipped with a variable adjustable float switch for automatic operation. The switch points depend on whether the pump is configured for clean or dirty water.
- Modo agua limpia: Switch-on point at 24 cm, switch-off point at 14 cm.
- Modo agua sucia: Switch-on point at 27.5 cm, switch-off point at 17.5 cm.

Image: Diagram illustrating the float switch activation and deactivation points for clean water pumping.

Image: Diagram illustrating the float switch activation and deactivation points for dirty water pumping.
5. Operación de la bomba
Once the pump is set up with the correct hose and pump base configuration for your application, plug it into a suitable power outlet (230V). The float switch will automatically activate the pump when the water level reaches the switch-on point and deactivate it when it drops to the switch-off point.
La bomba es adecuada para:
- Pumping and draining clear water.
- Pumping dirty water with particle sizes up to 30 mm.
- Dry drainage down to 1 mm.
- Emergency dewatering during floods.

Image: The pump being used in a construction pit and for draining a flooded basement, demonstrating its versatility.
5.1 Curva de rendimiento
The transport curve illustrates the relationship between the delivery head (Opvoerhoogte [m]) and the flow rate (Stroomsnelheid Q [m³/u]). This helps in understanding the pump's performance under different conditions.

Image: Graph showing the pump's performance curve, detailing flow rate versus head height.
5.2 Vortex Impeller
The pump is equipped with a vortex impeller, which helps prevent clogging and ensures low-maintenance operation, especially when handling dirty water.

Imagen: Detallada view of the pump's components, including the vortex impeller designed to prevent clogging.
6. Mantenimiento
Regular maintenance ensures the longevity and optimal performance of your T.I.P. Maxima 350 IPX DUO pump.
- Limpieza: After each use, especially with dirty water, rinse the pump with clean water to remove any debris.
- Inspección: Periodically check the power cable, plug, and float switch for any signs of damage.
- Almacenamiento: Guarde la bomba en un lugar seco y libre de heladas cuando no la utilice durante períodos prolongados.
- Comprobación del impulsor: If performance drops, check the impeller for blockages or wear.
7. Solución de problemas
Si tiene problemas con su bomba, consulte los siguientes pasos comunes de solución de problemas:
| Problema | Posible causa | Solución |
|---|---|---|
| La bomba no arranca | No power supply; Float switch not activated; Impeller blocked. | Check power connection; Ensure water level is above switch-on point; Clean impeller. |
| Reduced pumping capacity | Hose kinked or blocked; Impeller partially blocked; Pump base clogged. | Check and clear hose; Clean impeller and pump base. |
| La bomba funciona continuamente | Float switch stuck or faulty; Water level not dropping below switch-off point. | Check float switch for obstructions; Ensure proper water drainage. |
If the problem persists, contact T.I.P. customer support or a qualified technician.
8. Especificaciones
| Característica | Valor |
|---|---|
| Fabricante | T.I.P. |
| Número de modelo | 30274 |
| Dimensiones del producto | 16.9 x 19.8 x 39.1 cm |
| Peso | 7 kilogramos |
| Material | Stainless Steel (Acier inoxydable) |
| Fuente de poder | Eléctrico con cable |
| Volumentage | 230 voltios |
| Quétage | 800 vatios |
| Caudal máximo | 20,000 litros por hora |
| Altura máxima de la cabeza | 8 metros |
| Profundidad máxima de inmersión | 7 metros |
| Tamaño máximo de partícula | 30 mm (dirty water) / 1 mm (clean water) |
| Minimum Suction Height | 35 mm (dirty water) / 1 mm (clean water) |
| Temperatura media máxima | 35 °C |
| Longitud del cable de conexión | 10 m, H07RN8-F |
| Conexión de presión | 47.80 mm (1.5 inch external thread) |
9. Vídeos oficiales del producto
Watch these official videos for additional guidance on using your T.I.P. pump.
T.I.P. Extrema 300/10 Pro Waste Water Submersible Pump
Video: This video demonstrates the features and operation of the T.I.P. Extrema 300/10 Pro, a similar waste water submersible pump, providing a visual guide to handling and usage.
10. Garantía y soporte
T.I.P. provides high-quality and durable products. For any issues or questions regarding your Maxima 350 IPX DUO pump, please refer to the warranty information provided with your purchase or contact T.I.P. customer support.
T.I.P. offers a 10-year guarantee on the availability of spare parts, ensuring long-term support for your product.

Image: T.I.P. guarantees 10 years of spare parts availability for their products.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.