1. Producto terminadoview
The RCYAGO PH-W2839 is a versatile 3-in-1 monitor designed for comprehensive water quality analysis. It accurately measures pH, Oxidation-Reduction Potential (ORP), and temperature, providing real-time data and control capabilities. Equipped with WiFi connectivity, it integrates with the Tuya app for remote monitoring, data logging, and alarm settings, making it ideal for aquariums, aquaculture, and various water management applications.

Figura 1: The RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor, showing the main unit, connected pH, ORP, and temperature probes, and the dual-socket power control strip.

Figura 2: Key features of the 3-in-1 monitor, including accurate measurement, wide application range, and automatic temperature compensation.
2. Contenido del paquete
Por favor verifique que todos los artículos estén presentes en su paquete:
- 1 x WiFi Online pH ORP Temperature Controller Unit
- 1 x pH Electrode
- 1 x ORP Electrode
- Sonda de temperatura 1 x
- 1 x Dual-Socket Power Control Strip
- Calibration Powders (pH 4.01, pH 6.86/7.0, pH 9.18/10.01, ORP 256mV)
- 1 x adaptador de corriente
- Manual de usuario

Figura 3: Detallado view of the high-precision ORP electrode, pH electrode, temperature electrode, and the power plug included with the device.
3. Configuración e instalación
Follow these steps to set up your pH ORP Temperature Controller:
- Montaje del controlador: Choose a suitable location near your water body (aquarium, tank, etc.) and mount the main controller unit securely. Ensure it is protected from direct splashes.
- Conexión de electrodos: Carefully connect the pH electrode, ORP electrode, and temperature probe to their respective BNC connectors and jack on the main controller unit. Ensure connections are firm.
- Connecting Power Control Strip: Plug the dual-socket power control strip into the designated output port on the main controller. This strip will be used to connect external devices (e.g., CO2 solenoid valve, heater) that you wish to control based on pH or ORP levels.
- Colocación de la sonda: Submerge the pH electrode, ORP electrode, and temperature probe into the water you intend to monitor. Ensure the sensing parts of the electrodes are fully immersed and positioned to get accurate readings, away from strong currents or air bubbles.
- Conexión de energía: Plug the main controller's power adapter into a standard electrical outlet. The device will power on.
- WiFi Connection (Tuya App):
- Descarga la aplicación “Tuya Smart” o “Smart Life” desde la tienda de aplicaciones de tu dispositivo móvil (iOS o Android).
- Regístrese o inicie sesión en su cuenta.
- Follow the in-app instructions to add a new device. The controller should enter pairing mode automatically or by pressing the WiFi button.
- Connect the device to your 2.4GHz WiFi network.

Figura 4: A typical setup diagram showing the controller connected to a CO2 system and probes immersed in an aquarium.

Figura 5: The controller in operation, demonstrating WiFi connectivity and real-time data transfer to a mobile application.
4. Calibración
Regular calibration ensures the accuracy of your pH and ORP readings. It is recommended to calibrate the device upon initial setup and periodically thereafter.
4.1. Calibración de pH
The device supports 3-point pH calibration (pH 7.0, pH 4.01, pH 10.01).
- Prepare fresh pH buffer solutions (pH 7.0, pH 4.01, pH 10.01).
- Enjuague el electrodo de pH con agua destilada y séquelo suavemente.
- Sumerja el electrodo de pH en la solución tampón de pH 7.0.
- Press the 'CAL' button under the pH display on the controller. The device will automatically recognize the buffer and calibrate. Wait for the reading to stabilize.
- Rinse the electrode again.
- Repeat the process for pH 4.01 and pH 10.01 buffer solutions. Ensure to calibrate in ascending or descending order as per device prompts.
4.2. Calibración de ORP
The device supports ORP calibration using a 256mV standard solution.
- Prepare a fresh 256mV ORP standard solution.
- Rinse the ORP electrode with distilled water and gently blot dry.
- Immerse the ORP electrode into the 256mV standard solution.
- Press the 'CAL' button under the ORP display on the controller. The device will automatically recognize the standard and calibrate. Wait for the reading to stabilize.

Figura 6: Visual guide for the 3-point pH calibration and ORP calibration process using standard buffer solutions.
5. Instrucciones de funcionamiento
5.1. Monitoreo en tiempo real
Once powered on and probes are immersed, the controller's LCD screen will display real-time pH, ORP, and temperature readings. The WiFi indicator will show connection status.
5.2. Tuya App Functionality
The Tuya app provides advanced monitoring and control features:
- Datos en tiempo real: View current pH, ORP, and temperature readings remotely.
- Información histórica: Access daily, weekly, and monthly data logs for trend analysis.
- Configuración de alarma: Set high and low alarm thresholds for pH and ORP. Receive notifications on your mobile device if values exceed or fall below these thresholds.
- Smart Scene Creation: Create automated rules (smart scenes) within the Tuya app to control connected devices via the power strip. For example, turn on a CO2 solenoid when pH rises above a certain level.

Figura 7: The controller's display and the Tuya app interface, demonstrating real-time monitoring and alarm settings.

Figura 8: Illustration of the app's alarm setting capabilities, allowing users to define thresholds and trigger actions.

Figura 9: The device provides real-time data transmission, allowing users to view historical data trends over various periods.
6. Mantenimiento
Proper maintenance extends the lifespan and ensures the accuracy of your electrodes and controller.
- Limpieza de electrodos: Regularly clean the pH and ORP electrodes with distilled water to remove any buildup or contaminants. For stubborn deposits, use a mild cleaning solution specifically designed for electrodes, following the manufacturer's instructions.
- Almacenamiento de electrodos: When not in use, store the pH and ORP electrodes in their protective caps filled with a suitable storage solution (e.g., KCL solution or pH 4 buffer). Never store electrodes dry.
- Recalibración: Calibrate the pH and ORP electrodes regularly, especially if you notice inconsistent readings or after cleaning. The frequency depends on usage and water conditions.
- Unidad controladora: Keep the main controller unit clean and dry. Avoid exposing it to extreme temperatures or direct sunlight.
7. Solución de problemas
Si tiene problemas con su dispositivo, consulte los siguientes problemas y soluciones comunes:
| Problema | Posible causa | Solución |
|---|---|---|
| Inaccurate pH/ORP readings | Electrodes are dirty or aged; improper calibration; air bubbles on electrode. | Clean electrodes thoroughly; recalibrate the device; gently tap electrodes to dislodge bubbles. Replace electrodes if they are old or damaged. |
| Fallo de conexión WiFi | Incorrect WiFi password; device too far from router; 5GHz WiFi network used; router issues. | Ensure correct 2.4GHz WiFi password; move device closer to router; verify router is broadcasting 2.4GHz; restart router and device. |
| Relay output not triggering | Incorrect alarm settings in Tuya app; device not connected to power strip; external device malfunction. | Check and adjust pH/ORP alarm thresholds and smart scene rules in the app; ensure the external device is properly plugged into the control strip and functioning independently. |
| Lectura de temperatura incorrecta | Temperature probe not fully immersed or damaged. | Ensure the temperature probe is fully submerged; inspect the probe for physical damage. |
8. Especificaciones
Detailed technical specifications for the RCYAGO PH-W2839 monitor:

Figura 10: Encimaview of the device's measurement ranges, resolutions, and accuracy.
| Parámetro | Rango | Resolución | Exactitud |
|---|---|---|---|
| pH | 0.00pH - 14.00pH | 0.01 pH | ±0.1 pH |
| Remedio para el reflujo | -2000mV - +2000mV | 1mV | ±5 mV |
| Temperatura | 0 °C - 50 °C (32 °F - 122 °F) | 1.0 °C (0.2 °F) | ±1.0 °C |
- Fuente de alimentación: AC 110-240V, 50/60Hz (Specific adapter details may vary)
- Estándar WiFi: 2.4 GHz 802.11b/g/n
- Dimensiones: Approximately 11.1 x 8.11 x 2.99 inches (Controller unit)
- Peso: Aproximadamente 2.34 libras
9. Aplicaciones
The RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor is suitable for a wide range of water quality monitoring applications, including but not limited to:
- Aquariums (Freshwater and Seawater)
- Aquaculture and Fish Tanks
- Hydroponics and Plant Cultivation
- Piscinas y spas
- Domestic Water Quality Testing
- Laboratory Research and Testing

Figura 11: The versatility of the monitor across different water quality monitoring scenarios.




10. Garantía y soporte
This product comes with a standard manufacturer's warranty. For specific warranty terms, duration, and to register your product, please refer to the warranty card included in your package or visit the official RCYAGO websitio.
For technical support, troubleshooting assistance, or any inquiries regarding your RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor, please contact RCYAGO customer service through the contact information provided on their official websitio web o en la documentación de su producto.