KKmoon KKM828

KKmoon KKM828 2-in-1 Digital Multimeter with Oscilloscope User Manual

Model: KKM828

1. Introducción

The KKmoon KKM828 is a versatile 2-in-1 device combining the functionalities of a digital multimeter and an oscilloscope. Designed for efficiency and accuracy, it features a 2.4-inch color display, a 1MHz bandwidth for AC voltage, and a 2.5Msps real-time sampling rate. This manual provides essential information for safe and effective operation of your KKM828 device.

2. Información de seguridad

Please read and understand all safety instructions before using the device. Failure to follow these instructions may result in electric shock, fire, or damage to the device or other equipment.

  • Always ensure the device is in good working condition and free from damage before use.
  • No aplicar voltage or current that exceeds the maximum limits specified in the technical specifications.
  • Tenga cuidado al trabajar con vol.tages above 24V, as they pose a shock hazard. The device will emit an audible warning if the input voltage excede 24V.
  • Asegúrese de seleccionar la función y el rango correctos antes de realizar mediciones.
  • Reemplace las baterías rápidamente cuando aparezca el indicador de batería baja para garantizar lecturas precisas.
  • The device is equipped with double fuses (500mA/250V and 10A/250V) for protection. Do not bypass or use incorrect fuse types.
  • No opere el dispositivo en entornos húmedos o atmósferas explosivas.
  • Refer to the "Maintenance" section for proper cleaning and storage procedures.

3. Producto terminadoview

The KKmoon KKM828 integrates a digital multimeter and an oscilloscope into a compact, handheld unit. Key components and features are detailed below.

3.1 Características principales

  • Funcionalidad 2 en 1: Combines a digital multimeter and an oscilloscope.
  • Mostrar: 2.4-inch 320x240 LCM color screen for clear readings and waveform display.
  • Oscilloscope Performance: 1MHz ACV bandwidth, 2.5Msps real-time samptasa de ling.
  • Funciones del multímetro: Mide volumen CA/CCtage, corriente CA/CC, resistencia, capacitancia, frecuencia, ciclo de trabajo, diodo y continuidad.
  • Almacenamiento de datos: Stores up to 100 sets of data and 10 waveforms.
  • Interfaz de usuario: Silicone buttons and a pressure-sensitive dial for precise function selection.
  • Ergonomía: Integrated back bracket for a 60° viewángulo de ing.
  • Seguridad: Double fuse protection (500mA/250V, 10A/250V) and input voltagy advertencia.

3.2 Componentes del dispositivo

Consulte la imagen a continuación para obtener una descripción general.view of the device's main components.

KKmoon KKM828 Product Details: showing HD screen, function dial, and back bracket

Figure 1: KKM828 Product Details. This image highlights the device's HD color screen (01), the function dial for accurate gear changes (02), and the back bracket (03) for easy viewEn.

  • Pantalla HD: 2.4-inch color screen for clear display of measurements and waveforms.
  • Dial de función: Rotary switch for selecting measurement functions (voltage, current, resistance, etc.) and oscilloscope mode.
  • Buttons (F1-F4, R, S): Used for navigating menus, selecting ranges, holding data, and other specific functions.
  • Tomas de entrada: Terminals for connecting test leads for various measurements (e.g., VΩHz, mA, 10A, COM).
  • Soporte trasero: Foldable stand for propping up the device at a 60° angle for convenient viewEn.

4. Configuración

4.1 Instalación de la batería

The KKM828 requires three AA batteries for operation. Ensure the device is powered off before installing or replacing batteries.

  1. Localice la tapa del compartimiento de la batería en la parte posterior del dispositivo.
  2. Open the battery compartment cover by sliding or unscrewing it (if applicable).
  3. Insert three AA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  4. Cierre bien la tapa del compartimento de la batería.

4.2 Encendido / Apagado

To power on the device, rotate the function dial from the "OFF" position to any desired measurement function. To power off, rotate the dial back to the "OFF" position.

5. Instrucciones de funcionamiento

5.1 Funciones del multímetro

The KKM828 offers a comprehensive range of multimeter measurement capabilities. Always connect test leads correctly to the appropriate input jacks (e.g., COM, VΩHz, mA, 10A) for the selected function.

  • Vol. CA / CCtagmi Medida: Rotate the dial to the 'V~' or 'V=' position. Connect test leads in parallel with the circuit.
  • Medición de corriente CA/CC: Rotate the dial to the 'mA~', 'mA=', '10A~', or '10A=' position. Connect test leads in series with the circuit.
  • Medida de resistencia: Rotate the dial to the 'Ω' position. Ensure the circuit is de-energized before measuring resistance.
  • Medición de capacitancia: Rotate the dial to the 'mF' position. Discharge capacitors before measurement.
  • Medición de frecuencia y ciclo de trabajo: Rotate the dial to the 'Hz%' position.
  • Prueba de diodo: Rotate the dial to the 'Diode' position. Connect leads across the diode to check forward voltage gota.
  • Prueba de continuidad: Rotate the dial to the 'Continuity' position. The device will beep if resistance is below approximately 50Ω.
KKmoon KKM828 Multimeter Functions: showing frequency, duty cycle, diode test, and continuity test

Figure 2: Multimeter Measurement ExampLes. This image illustrates the display during Frequency, Duty Cycle, Diode Test, and Continuity measurements, demonstrating the device's various multimeter functions.

5.2 Funciones del osciloscopio

The KKM828 features a convenient one-button oscilloscope for waveform analysis.

  1. Rotate the function dial to the 'Graphical' (oscilloscope) mode.
  2. Connect the test leads to the circuit where you wish to observe the waveform.
  3. The device will automatically display the waveform. Use the secondary display at the bottom to view parameters such as Peak-to-Peak voltage (VP-P), average value, RMS value, frequency, time base, and amplitud
  4. Measurement modes include 'Normal' and 'Automatic'. The device can quickly and accurately measure and display waveforms.
KKmoon KKM828 Waveform Display: showing various electrical waveforms on the oscilloscope screen

Figure 3: Oscilloscope Waveform Display. Esta imagen muestra examples of different electrical waveforms (sine, square, pulse, complex) as displayed on the KKM828's oscilloscope screen, along with key measurement parameters.

5.3 Almacenamiento y recuperación de datos

The KKM828 can store up to 100 sets of measurement data and 10 waveforms for later review.

  • Specific instructions for saving and recalling data are typically accessed via the function buttons (e.g., 'S' for Save, 'R' for Recall) in relevant measurement modes. Refer to the on-screen prompts for detailed operation.
  • The device allows for simultaneous display of historical records and real-time data for easy comparison and analysis.

6. Mantenimiento

6.1 Limpieza

To clean the device, wipe the casing con anuncioamp cloth and a mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any circuits before cleaning. Do not allow moisture to enter the device.

6.2 Reemplazo de batería

When the low battery indicator appears on the display, replace the three AA batteries as described in the "Battery Installation" section (4.1). Always use fresh batteries of the same type.

6.3 Almacenamiento

When not in use for extended periods, remove the batteries to prevent leakage. Store the device in a cool, dry place within the specified storage environment: -10°C to 60°C, with relative humidity less than 90% RH.

7. Solución de problemas

This section addresses common issues you might encounter with your KKM828 device.

ProblemaPosible causaSolución
El dispositivo no se enciende.Baterías muertas o instaladas incorrectamente.Compruebe la polaridad de las pilas y sustitúyalas por pilas AA nuevas.
No se muestra ninguna lectura o "OL" (Sobrecarga).Incorrect range selected, open circuit, or input exceeds maximum limit.Select appropriate range, check test lead connections, ensure circuit is closed. Verify input does not exceed specifications.
Medidas inexactas.Low battery, incorrect connection, or environmental factors.Replace batteries, re-check test lead connections, ensure operating environment is within specified range.
Oscilloscope waveform is unstable or absent.Poor connection, signal too weak/strong, or incorrect mode.Ensure secure test lead connection. Adjust amplitude or time base if available (though KKM828 is mostly auto-ranging). Verify signal source.
El dispositivo emite un pitido continuo.Vol de entradatage exceeds 24V (safety warning).Immediately disconnect the device from the circuit and verify the voltage level. Do not proceed if voltage es demasiado alto.

8. Especificaciones

The following table details the technical specifications of the KKmoon KKM828.

ParámetroValor
ModeloKKM828
Mostrar2.4-inch 320 x 240 LCM Color Screen
Resistencia de entrada10 MΩ
Tipo de batería3 pilas AA (no incluidas)
Consumo de energíaAprox. 80mA
Operating Time (low brightness)Aproximadamente 5 horas
Almacenamiento de datos100 data sets / 10 waveforms
Entorno operativo0 ~ 40 °C, <75% RH
Entorno de almacenamiento-10 ~ 60 °C, <90% RH
Bandwidth (ACV)1 MHz
Bandwidth (ACA)5 kHz
Max. Real-time Samptasa de ling2.5 Msps
Multimeter Range (DC Voltage)400mV / 4V / 40V / 400V / 1000V (Accuracy: 0.75% rdg + 10dgt)
Multimeter Range (AC Voltage)400mV / 4V / 40V / 400V / 750V (Accuracy: 1.0% rdg + 10dgt)
Multimeter Range (DC Current)40mA / 400mA / 4A / 10A (Accuracy: 1.2% rdg + 10dgt)
Multimeter Range (AC Current)40mA / 400mA / 4A / 10A (Accuracy: 1.5% rdg + 10dgt)
Multimeter Range (Resistance)400.0 Ω ~ 40.00 MΩ (Accuracy: 1.0% rdg + 5dgt)
Multimeter Range (Capacitance)0.1nF ~ 100, 10.00mF (Accuracy: 2.0% rdg + 10dgt)
Multimeter Range (Frequency)5Hz ~ 10MHz (Accuracy: 1.0% rdg + 5dgt)
Multimeter Range (Duty Cycle)0.1 % ~ 99.9 % (Accuracy: 1.0% rdg + 5dgt)
Prueba de diodoVolumentage approx. 5V, Test current approx. 1.5mA
Prueba de continuidadEl zumbador suena si la resistencia < 50 Ω
Especificaciones del fusible500mA / 250V, 10A / 250V
Dimensiones160 x 83 x 32 mm
Peso195 gramos

© 2023 KKmoon. All rights reserved.