Thank you for choosing the Rebel POWER-800 RB-4012 Pure Sine Wave Inverter. This device is designed to convert 12V DC power from a battery into 230V AC pure sine wave power, suitable for a wide range of electronic appliances. It also features an integrated charging function, allowing it to act as an emergency power supply. Please read this manual thoroughly before installation and operation to ensure safe and efficient use of your inverter.

Instrucciones de seguridad

  • Always connect the inverter to a 12V DC battery system. Connecting to other voltagPuede causar daños.
  • Ensure proper ventilation around the inverter to prevent overheating. Do not block ventilation openings.
  • Mantenga el inversor alejado del agua, la humedad, los materiales inflamables y la luz solar directa.
  • No abra el inversor casing. No hay piezas que el usuario pueda reparar en el interior. Encargue cualquier reparación a personal cualificado.
  • Asegúrese de que todas las conexiones sean seguras y estén correctamente polarizadas para evitar riesgos eléctricos.
  • Desconecte la batería antes de realizar cualquier mantenimiento o limpieza.
  • This device is equipped with built-in protection against overload, short circuit, overvoltage, bajo volumentage, and overheating. However, always operate within specified limits.

Producto terminadoview

Familiarize yourself with the components of your Rebel POWER-800 RB-4012 inverter.

Frente view of Rebel POWER-800 RB-4012 Pure Sine Wave Inverter

Figura 1: Panel frontal
This image shows the front of the Rebel POWER-800 inverter, featuring the digital LED display, two AC output sockets, and the DC input cables (red and black) for battery connection. The display provides real-time status information.

Trasero view of Rebel POWER-800 RB-4012 Pure Sine Wave Inverter

Figura 2: Panel trasero
This image displays the rear of the Rebel POWER-800 inverter. It includes a cooling fan for heat dissipation, two AC output sockets, the AC input port for grid connection, and a circuit breaker for protection.

Presupuesto

CaracterísticaEspecificación
Potencia nominal500 W
Tipo de batería12 V CC
Volumen máximo de la bateríatage15 V CC
Vol de entradatage Rango (CA)180 ~ 275 V CA
Frecuencia de entrada45 ~ 60 Hz
Vol de salidatage Rango (CA)230 V CA +/-8%
Frecuencia de salida50/60Hz +/-0.5Hz
Forma de onda de salidaDe onda sinusoidal pura
Output Efficiency (DC to AC)> = 85%
Corriente de carga de la bateríaMáx. 10 A
Tiempo de conmutación<= 4 ms
Funciones de protecciónSobrecarga, cortocircuito, sobrevol.tage, subvol.tage, sobrecalentamiento
Temperatura de funcionamiento0-40 °C
Humedad10-90%
Dimensiones (L x An x Al)215 x 265 x 100 mm
Peso4.7 kilogramos

Configuración

  1. Conexión de la batería: Connect the red DC cable from the inverter to the positive (+) terminal of your 12V battery. Connect the black DC cable to the negative (-) terminal. Ensure connections are tight and secure. Incorrect polarity will damage the unit.
  2. AC Input (Grid Connection): If you intend to use the charging function or have the inverter act as an emergency power supply, connect the AC input cable to a standard 230V AC wall outlet.
  3. AC Output (Device Connection): Plug your 230V AC appliances into the output sockets on the inverter's front or rear panel. Ensure the total power consumption of connected devices does not exceed the inverter's rated power of 500W.
  4. Colocación: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure there is adequate space around the cooling fan.

Instrucciones de funcionamiento

  1. Encendido: After all connections are made, switch on the inverter. The LED display will illuminate, showing the current status, including input voltage, volumen de salidatage, y el nivel de carga de la batería.
  2. Monitoreo de la pantalla: The LED display provides real-time information. Monitor it for battery status, AC input/output voltage, y cualquier indicador de error.
  3. Función de carga: When the inverter is connected to both a battery and an AC grid source, it will automatically charge the connected 12V battery. The display will indicate the charging status.
  4. Fuente de alimentación de emergencia: En caso de un corte de energíatage (loss of AC grid input), the inverter will automatically switch to battery power, providing continuous 230V AC output to connected devices within 4ms.
  5. Apagado: To turn off the inverter, first disconnect all AC appliances, then switch off the inverter, and finally disconnect the AC input cable (if connected) and battery cables.

Mantenimiento

  • Limpieza: Limpie periódicamente el exterior del inversor con un paño suave y seco. No utilice limpiadores líquidos ni disolventes. Asegúrese de que las aberturas de ventilación estén libres de polvo y residuos.
  • Cuidado de la batería: Ensure your 12V battery is well-maintained and charged. The inverter's charging function helps maintain battery health when connected to the grid.
  • Comprobaciones de conexión: Periodically check all electrical connections (DC and AC) to ensure they remain tight and free from corrosion.
  • Almacenamiento: If storing the inverter for an extended period, disconnect it from the battery and AC power. Store in a cool, dry place.

Solución de problemas

ProblemaPosible causaSolución
Sin salida de potenciaBatería no conectada o con bajo volumentage; Inverter switched off; Blown fuse/circuit breaker.Check battery connections and charge level; Ensure inverter is switched on; Reset circuit breaker or check internal fuse (if accessible and safe).
Advertencia de sobrecargaConnected appliances exceed 500W rated power.Reduce la carga desconectando algunos electrodomésticos.
Advertencia de sobrecalentamientoMala ventilación; Carga excesiva.Ensure adequate airflow around the inverter; Reduce load. Allow unit to cool down.
Protección contra cortocircuitos activadaShort circuit in connected appliance or wiring.Disconnect all appliances and check for faulty wiring or devices. Reconnect one by one to identify the faulty item.
La batería no se cargaEntrada de CA no conectada; volumen de entrada de CAtage too low/high; Faulty battery.Ensure AC input cable is securely connected to a live outlet; Check AC input voltage; Test battery condition.

Garantía y soporte

Rebel products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact your retailer. Keep your purchase receipt as proof of purchase.