1. Introducción
The Thermalright FW 360 White ARGB is a high-performance 360mm All-in-One (AIO) liquid CPU cooler designed for efficient heat dissipation in desktop computers. It features a new generation water pump system, three PWM fans with ARGB lighting, and an integrated IPS LCD screen for real-time system monitoring and customization. This manual provides essential information for the installation, operation, and maintenance of your FW 360 cooler.

Image 1.1: Thermalright FW 360 White ARGB Liquid CPU Cooler.
2. Contenido del paquete
Verifique que todos los componentes estén presentes en el paquete:
- Thermalright FW 360 White ARGB Liquid CPU Cooler (Radiator, Pump/Cold Plate with IPS LCD, and three pre-installed TL-P12W-S PWM ARGB Fans)
- Mounting hardware for AMD (AM4 / AM5) and Intel (LGA1150/1151/1155/1156/1200/2011/2066/1700) platforms
- Water tube clips
- Manual de usuario (este documento)
3. Compatibilidad
The Thermalright FW 360 Liquid CPU Cooler is compatible with a wide range of CPU sockets:
- AMD: AM4, AM5
- Información: LGA1150, LGA1151, LGA1155, LGA1156, LGA1200, LGA2011, LGA2066, LGA1700
Ensure your motherboard has a 5V 3-pin ARGB connector for lighting synchronization.

Image 3.1: Supported Motherboard Sockets.
4. Configuración e instalación
The installation process for the Thermalright FW 360 is designed to be straightforward. Each platform includes the corresponding mounting hardware.
4.1 Pasos generales de instalación
- Prepare su placa base: Install the appropriate backplate and standoffs for your CPU socket (AMD or Intel).
- Monte el radiador: Secure the 360mm radiator to your PC case. The fans are pre-installed for convenience.
- Instalar la bomba/placa fría: Apply thermal paste to your CPU (if not pre-applied on the cold plate). Place the pump/cold plate assembly onto the CPU and secure it using the SS2 metal buckle system. This system ensures uniform contact pressure.
- Conectar cables:
- Connect the pump's power cable to the designated header on your motherboard.
- Connect the fan PWM cables to the CPU_FAN or other fan headers on your motherboard.
- Connect the ARGB cables from the fans and pump to a 5V 3-pin ARGB header on your motherboard for lighting synchronization.
- Sistema de organización de cables: Use the provided water tube clips and other cable ties to manage the tubing and cables for a clean build and optimal airflow.
Importante: For detailed visual instructions, it is highly recommended to refer to the official installation video or the comprehensive manual provided with your product. Incorrect installation can lead to poor cooling performance or damage to components.

Image 4.1: SS2 Metal Buckle System for secure mounting.
5. Instrucciones de funcionamiento
5.1 IPS LCD Screen Functionality
The integrated 2.4-inch IPS LCD screen (320x240 resolution) on the pump block provides real-time system monitoring and customization options.
- Monitoreo del sistema: Display CPU temperature, GPU temperature, clock frequencies, and other system statistics.
- Personalización: Supports various static and dynamic image changes, including GIFs and videos. You can also project your system's screen (software dependent).
- Ajustabilidad: The screen can be freely adjusted for optimal viewEn.

Image 5.1: Real-time system monitoring on the IPS LCD screen.

Image 5.2: Customizable animations and standby themes.
5.2 Fan and ARGB Control
The TL-P12W-S fans feature PWM (Pulse Width Modulation) control, allowing their speed to automatically adjust based on CPU temperature, optimizing cooling performance and noise levels.
- Control PWM: Connect the fan PWM cables to your motherboard's fan headers to enable automatic speed control.
- Sincronización ARGB: Connect the ARGB cables to a 5V 3-pin ARGB header on your motherboard. Use your motherboard's software or a compatible ARGB controller to customize lighting effects and synchronize them with other ARGB components in your system.

Image 5.3: TL-P12W-S ARGB Fan with specifications.
6. Mantenimiento
Regular maintenance helps ensure optimal performance and longevity of your liquid CPU cooler.
- Limpieza de polvo: Periodically clean the radiator fins and fan blades using compressed air to remove dust buildup. Dust can impede airflow and reduce cooling efficiency.
- Inspeccionar los tubos y las conexiones: Occasionally check the liquid tubes and connections for any signs of leaks or damage. While the tubes are protected against liquid evaporation, regular inspection is recommended.
- Inspección del ventilador: Ensure fans are spinning freely and quietly. If a fan becomes noisy or stops spinning, it may need replacement.
- Pasta térmica: If you ever remove the cold plate from the CPU, clean off the old thermal paste and apply a fresh layer before reinstallation.
7. Solución de problemas
If you encounter issues with your Thermalright FW 360 cooler, refer to the following common troubleshooting steps:
- Altas temperaturas de la CPU:
- Ensure the pump is running and connected correctly.
- Verify that the fans are spinning and connected to appropriate headers.
- Compruebe que la placa fría esté en contacto correcto con la CPU. Vuelva a aplicar pasta térmica si es necesario.
- Limpie el polvo de las aletas del radiador.
- Los ventiladores no giran/ARGB no se enciende:
- Check all power and ARGB cable connections to the motherboard.
- Ensure your motherboard's 5V 3-pin ARGB header is enabled in the BIOS/UEFI or through motherboard software.
- Test fans individually if possible.
- Ruido de la bomba:
- Asegúrese de que la bomba esté montada de forma segura y no vibre contra otros componentes.
- Check for air bubbles in the loop (though less common in AIOs, tilting the case can sometimes help).
- La pantalla LCD no se muestra:
- Verify the display's power and data cables are securely connected.
- Ensure any required software for the display is installed and running.
If problems persist, please contact Thermalright customer service for further assistance.
8. Especificaciones
| Característica | Especificación |
|---|---|
| Marca | Derecho térmico |
| Modelo | FW 360 White ARGB |
| Método de enfriamiento | Líquido (todo en uno) |
| Dimensiones del radiador | 397 mm x 120 mm x 27 mm |
| Dimensiones del producto (total) | 39.7L x 2.7H cm |
| Material | Aluminio |
| Dispositivos compatibles | Computadoras de escritorio |
| Compatibilidad del zócalo de la CPU | AMD: AM4 / AM5, Intel: LGA1150/1151/1155/1156/1200/2011/2066/1700 |
| Modelo de ventilador | TL-P12W-S |
| Dimensiones del ventilador | 120 mm x 120 mm x 25 mm |
| Velocidad del ventilador (máx.) | 2000 RPM ±10% |
| Flujo de aire (máx.) | 70.84 pies cúbicos por minuto |
| Nivel de ruido (máx.) | 29.8 decibelios |
| Conector de alimentación del ventilador | 4-pin PWM |
| Conector ARGB | ARGB de 5 pines y 3 V |
| Volumen de la bombatage | 12 voltios (CC) |
| Pump Wattage | 3.4 vatios |
| IPS LCD Screen Resolution | 320 x 240 |
| Componentes incluidos | Enfriador líquido de CPU |
| País natal | Porcelana |
| Código Postal | 755225214595 |
9. Garantía y soporte
For warranty information, please refer to the documentation included with your purchase or the official Thermalright websitio.
If you have any questions, require technical assistance, or encounter issues not covered in this manual, please contact Thermalright customer service. Contact details can typically be found on the product packaging or the official Thermalright websitio.