1. Introducción
Thank you for choosing the EVURU SS-001 Rocker Switch Overload Current Protector Circuit Breaker. This device is designed to provide reliable overload protection for electrical circuits, combining the functionality of a power switch with an integrated circuit breaker. This manual provides essential information for the safe and effective installation, operation, and maintenance of your circuit breaker.
2. Información de seguridad
Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or other serious injury.
- Peligro eléctrico: Always disconnect power to the circuit before installing or servicing the circuit breaker.
- Personal calificado: Installation and wiring should be performed by a qualified electrician or knowledgeable individual familiar with electrical systems.
- Calificación correcta: Ensure the circuit breaker's current rating (e.g., 16A) matches the requirements of your application to prevent damage or fire.
- Condiciones ambientales: No exponga el dispositivo a la humedad, temperaturas extremas o ambientes corrosivos.
- Inspección: Regularly inspect the circuit breaker for any signs of damage, wear, or loose connections.
3. Producto terminadoview
The EVURU SS-001 is a miniature, single-pole rocker switch circuit breaker designed for trip-free overload current protection. It integrates an ON/OFF switch with a thermal circuit breaker, making it suitable for various applications such as power strips, appliances, and industrial equipment. When an overload occurs, the breaker automatically trips, disconnecting the circuit to prevent damage. It can then be reset manually.

Características principales:
- Funcionalidad integrada: Combines ON/OFF switching with overload protection.
- Trip-Free Design: Ensures the circuit remains open during an overload, even if the switch is held in the ON position.
- Unipolar: Designed for single-phase circuits.
- Tamaño compacto: Miniature design for easy integration into various devices.
- Calificación actual: Available in various current ratings, such as 10A and 16A.
4. Configuración e instalación
Proper installation is crucial for the safe and effective operation of the circuit breaker. If you are unsure about any step, consult a qualified electrician.
Pasos de instalación:
- Desconectar la energía: Before beginning any work, ensure that the main power supply to the circuit is completely disconnected. Verify with a voltage probador.
- Preparar la ubicación de montaje: The SS-001 is designed for panel mounting. Cut an appropriately sized opening in the panel according to the dimensions provided in the specifications section or technical drawing.
- Insert Breaker: Carefully insert the circuit breaker into the prepared opening until it snaps securely into place.
- Conexiones de cable: Connect the electrical wires to the appropriate terminals on the underside of the circuit breaker. Refer to the wiring diagram (if available for your specific application) and ensure all connections are tight and secure. The terminals are typically marked for input and output.
- Verificar instalación: Double-check all wiring and mounting to ensure everything is correct and secure.
- Restaurar energía: Una vez completada y verificada la instalación, restablezca la energía al circuito.


5. Instrucciones de funcionamiento
Operating the EVURU SS-001 circuit breaker is straightforward:
- Encendiendo: Press the rocker switch to the 'ON' position (typically indicated by the 'RESET' side being depressed or a visual indicator). The circuit is now energized.
- Apagando: Press the rocker switch to the 'OFF' position. The circuit is now de-energized.
- Protección contra sobrecarga: If an overload current occurs, the circuit breaker will automatically trip, moving the rocker switch to the 'OFF' or a neutral position. This protects the circuit from damage.
- Reinicio del disyuntor: After an overload trip, identify and resolve the cause of the overload. Once the issue is corrected, press the rocker switch firmly to the 'RESET' position to re-energize the circuit. If the breaker immediately trips again, the overload condition still exists or there is a fault in the circuit.
6. Mantenimiento
The EVURU SS-001 circuit breaker requires minimal maintenance. However, periodic checks are recommended to ensure continued safe and reliable operation:
- Inspección visual: Periodically inspect the circuit breaker for any physical damage, discoloration, or signs of overheating.
- Limpieza: Keep the area around the circuit breaker clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Verificación de conexión: Ensure all wire connections remain tight. Loose connections can lead to overheating and poor performance.
- Prueba de funcionalidad: If possible and safe to do so, periodically test the trip function by simulating an overload (only if you have the proper equipment and expertise). Otherwise, rely on its automatic protection.
7. Solución de problemas
If you encounter issues with your EVURU SS-001 circuit breaker, refer to the following troubleshooting guide:
| Problema | Posible causa | Solución |
|---|---|---|
| El disyuntor se dispara inmediatamente después del reinicio. | Sobrecarga o cortocircuito persistente en el circuito conectado. | Disconnect all loads from the circuit. Reset the breaker. If it still trips, there is a fault in the wiring. If it holds, reconnect loads one by one to identify the faulty device. |
| Breaker does not trip during an apparent overload. | Breaker is undersized for the load, faulty breaker, or incorrect wiring. | Verify the current draw of the load does not exceed the breaker's rating. Replace the breaker if it is suspected to be faulty. Check wiring for correct connections. |
| Switch does not stay in the ON position. | Internal mechanical fault or continuous overload. | Ensure no overload is present. If the issue persists, the breaker may be faulty and require replacement. |
| Switch feels loose or unresponsive. | Physical damage or internal wear. | Replace the circuit breaker. |
Si los pasos de solución de problemas no resuelven el problema, comuníquese con un electricista calificado o con el fabricante para obtener ayuda.
8. Especificaciones
The following are general specifications for the EVURU SS-001 Rocker Switch Overload Current Protector Circuit Breaker. Specific ratings may vary by model variant (e.g., 10A, 16A).
- Modelo: SS-001
- Marca: EVURU
- Tipo: Miniature Circuit Breaker, Rocker Switch
- Número de polos: 1
- Calificación actual: 16A (as per specific variant)
- Volumentage Clasificación: 250VAC (as per image details)
- Frecuencia: 50/60 Hz
- Tipo de protección: Overload Current Protection (Trip-Free)
- Certificaciones: CUL, VDE (as per image details)
- Dimensiones aproximadas del paquete: 1.18 x 0.79 x 0.39 pulgadas (30 x 20 x 10 mm)
- Peso aproximado del artículo: 1.76 onzas (50 gramos)

9. Garantía y soporte
For warranty information or technical support regarding your EVURU SS-001 Rocker Switch Overload Current Protector Circuit Breaker, please refer to the product packaging or contact your point of purchase. Keep your purchase receipt as proof of purchase.