VEVOR VBPYCE-110

VEVOR VBPYCE-110 Variable Frequency Pool Heat Pump

Manual de usuario

1. Introducción

Thank you for choosing the VEVOR VBPYCE-110 Variable Frequency Pool Heat Pump. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new pool heat pump. Please read this manual thoroughly before installation and use, and retain it for future reference.

The VBPYCE-110 is designed to provide both heating and cooling for swimming pools ranging from 25 m³ to 50 m³, ensuring comfortable water temperatures year-round. Its variable frequency technology offers energy efficiency and quiet operation.

2. Instrucciones de seguridad

ADVERTENCIA: No seguir estas instrucciones de seguridad podría provocar descargas eléctricas, incendios, lesiones graves o la muerte.

  • Ensure the unit is installed by a qualified technician in accordance with all local and national electrical and plumbing codes.
  • Desconecte siempre la alimentación de la unidad antes de realizar cualquier mantenimiento o servicio.
  • Do not operate the unit if any part is damaged or missing.
  • Mantenga a los niños y a las personas no autorizadas lejos de la unidad durante su funcionamiento.
  • Do not block the air intake or exhaust vents of the heat pump.
  • La unidad debe estar correctamente conectada a tierra.
  • Do not use flammable liquids or gases near the heat pump.

3. Componentes del producto

The VEVOR VBPYCE-110 heat pump consists of several key components designed for efficient performance and durability.

Internal components of VEVOR VBPYCE-110 pool heat pump, showing evaporator, copper piping, compressor base, and control panel.

Figura 3.1: Diagrama de componentes internos
This diagram illustrates the main internal components of the heat pump, including the evaporator, all-pure copper piping, floating compressor base, and main control panel. These elements work together to ensure efficient heat transfer and quiet operation.

  • Evaporador: Designed for efficient heat absorption, contributing to power savings.
  • All-Pure Copper Piping: Ensures rapid heating and excellent thermal conductivity.
  • Floating Compressor Base: Reduces vibration and noise during operation.
  • Panel de control principal: Provides easy access for operation and settings adjustment.
  • Titanium Tube Heat Exchanger: Highly resistant to salt, chlorine, and corrosion, ensuring long-term durability.

4. Instalación

Proper installation is crucial for the performance and longevity of your heat pump. Consult a qualified professional for installation.

4.1 Selección del sitio

  • Choose a location with adequate airflow, away from obstructions.
  • Asegúrese de que la unidad esté colocada sobre una superficie estable y nivelada.
  • Maintain sufficient clearance around the unit for maintenance and proper air circulation (refer to specifications for exact distances).
  • The unit can be installed for both above-ground and in-ground pools.
VEVOR VBPYCE-110 pool heat pump installed next to an above-ground pool and an in-ground pool.

Figura 4.1: Instalación ExampLos
The heat pump can be integrated with various pool types, including above-ground and in-ground installations, provided proper clearances and connections are maintained.

4.2 Conexiones de fontanería

  • Connect the heat pump to your pool's filtration system after the filter and before any chemical feeders.
  • Use the provided universal metric-imperial connector kit for secure connections.
  • Asegúrese de que todas las conexiones sean estancas para evitar fugas.

4.3 Conexiones eléctricas

  • The unit requires an AC 220-240V, 50Hz power supply.
  • Todo el cableado eléctrico debe cumplir con los códigos locales y ser realizado por un electricista autorizado.
  • Install a dedicated circuit breaker for the heat pump.
  • Asegure una conexión a tierra adecuada para evitar riesgos eléctricos.

5. Instrucciones de funcionamiento

The VBPYCE-110 heat pump features a user-friendly control panel for setting desired temperatures and operating modes.

Graph showing minimal water temperature fluctuations and heating range of VEVOR pool heat pump.

Figure 5.1: Temperature Control Range
The heat pump maintains minimal water temperature fluctuations, enhancing swimming comfort. The heating temperature range is 9-40°C (48.2-104°F).

Diagram illustrating quiet operation of VEVOR pool heat pump with noise level comparison.

Figura 5.2: Funcionamiento silencioso
Equipped with inverter technology, the heat pump operates at a noise level below 58 dB at 1 meter, ensuring minimal disruption.

5.1 Panel de control terminadoview

De cerca view of the VEVOR VBPYCE-110 pool heat pump, showing the side-mounted control panel.

Figura 5.3: Ubicación del panel de control
The main control panel is located on the side of the unit, providing access to various settings and operational data. It supports RS485 connection for integration with a control center.

The main control panel typically includes:

  • Botón de encendido: Para encender/apagar la unidad.
  • Selección de modo: To switch between heating, cooling, and automatic modes.
  • Ajuste de temperatura: Up/Down arrows to set the desired water temperature.
  • Pantalla de visualización: Shows current water temperature, set temperature, and operating status.

5.2 Ajuste de la temperatura deseada

  1. Turn on the heat pump using the power button.
  2. Select the desired operating mode (heating or cooling).
  3. Use the temperature adjustment buttons to set your preferred pool water temperature. The unit will automatically work to reach and maintain this temperature.

The heating temperature range is 9-40°C (48.2-104°F), and the cooling temperature range is 8-28°C (46.4-82.4°F).

6. Mantenimiento

Regular maintenance ensures optimal performance and extends the lifespan of your VEVOR heat pump.

6.1 Controles de rutina

  • Clean the Coils: Periodically inspect and clean the evaporator coils to remove dirt, leaves, and debris that can obstruct airflow.
  • Comprobar el flujo de agua: Ensure there is adequate water flow through the heat pump. Reduced flow can impact efficiency.
  • Inspeccione si hay fugas: Regularly check all plumbing connections for any signs of leaks.
  • Obstrucciones claras: Ensure the area around the heat pump is free from obstructions to allow for proper air circulation.
Internal components of VEVOR VBPYCE-110 pool heat pump, highlighting durable materials like copper piping and titanium heat exchanger.

Figura 6.1: Características de durabilidad
The heat pump features a spiral titanium tube heat exchanger and all-pure copper piping, providing excellent resistance to salt, chlorine, and corrosion, which contributes to its long-term durability and reduced maintenance needs.

6.2 Preparación para el invierno

If you live in an area where temperatures drop below freezing, it is essential to winterize your heat pump to prevent damage:

  1. Desconecte la alimentación de la unidad.
  2. Drain all water from the heat pump and plumbing lines to prevent freezing.
  3. Cubra la unidad con una funda protectora y transpirable.

7. Solución de problemas

This section provides solutions to common issues you might encounter with your VEVOR pool heat pump. For problems not listed here, contact customer support.

Problema Posible causa Solución
La bomba de calor no se enciende. No hay suministro de energía; disyuntor disparado; cableado defectuoso. Check power connection and circuit breaker. Consult an electrician if wiring is suspected.
Calefacción/refrigeración insuficiente. Low water flow; dirty coils; incorrect temperature setting; ambient temperature too low/high. Ensure pump is running and filter is clean. Clean evaporator coils. Verify temperature settings. Check operating environment temperature limits.
La unidad es ruidosa. Componentes sueltos; obstrucción del ventilador; unidad desnivelada. Check for loose parts. Clear any obstructions from the fan. Ensure the unit is on a level surface.
Fugas de agua. Loose plumbing connections; damaged O-rings or seals. Tighten all plumbing connections. Inspect and replace any damaged seals.

8. Especificaciones

Detailed technical specifications for the VEVOR VBPYCE-110 Variable Frequency Pool Heat Pump.

Dimensions and technical specifications of VEVOR VBPYCE-110 pool heat pump, including a list of included accessories.

Figura 8.1: Dimensiones del producto y accesorios incluidos
This image provides a visual representation of the heat pump's dimensions and lists the accessories included with the unit.

Característica Detalle
Número de modelo VBPYCE-110
Potencia máxima de entrada 2.81 kW
Capacidad de calefacción nominal 2.51 - 11.38 kW
Rango de temperatura de calentamiento 9-40 °C (48.2-104 °F)
Rango de temperatura de enfriamiento 8-28 °C (46.4-82.4 °F)
Tamaño de piscina recomendado 25 - 50 m³
Temperatura del entorno de funcionamiento -10 a 40 °C (14 a 104 °F)
Fuente de alimentación CA 220-240 V, 50 Hz
Nivel de ruido < 58 dB (at 1m)
Peso neto 48.5 kg (107.0 libras)
Dimensiones del producto (L x An x Al) 91 x 36 x 62 cm (35.7 x 14.2 x 24.5 pulgadas)
Material principal Acero carbono

8.2 Accesorios incluidos

  • 1 x Manual de usuario
  • 4 x Almohadillas amortiguadoras
  • 2 x Drain Nozzle
  • 1 x 2m Drain Hose
  • 2 x Universal Metric-Imperial Connector Kit

9. Garantía y soporte

Para obtener información sobre la garantía y soporte técnico, consulte la tarjeta de garantía incluida con su producto o visite el sitio web oficial de VEVOR. webSitio. Conserve su recibo de compra como comprobante de compra.

For assistance, contact VEVOR customer service with your model number (VBPYCE-110) and purchase details.

© 2025 VEVOR. Todos los derechos reservados.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.