Introducción
The MAXUS Gold Milligram Scale D205 is a high-precision digital scale designed for accurate measurements up to 100g with 0.001g readability. It is suitable for various applications including weighing powders, jewelry, and reloading components. This manual provides detailed instructions for setting up, operating, and maintaining your scale to ensure optimal performance.

Image: The MAXUS Gold Milligram Scale D205, showcasing su diseño compacto y pantalla digital.
Contenido del paquete
Verifique que todos los artículos estén presentes en el paquete:
- MAXUS Gold Milligram Scale D205
- 20g Calibration Weight (x2)
- Weighing Pan/Tray
- Cuchara
- Pinzas
- Cable USB-C
- Pilas AAA (x2)

Image: All components included with the MAXUS Gold Milligram Scale D205.
Configuración
1. Fuente de alimentación
The MAXUS D205 scale can be powered by two AAA batteries or via the included USB-C cable.
- Energía de la batería: Open the battery compartment on the underside of the scale and insert two AAA batteries, ensuring correct polarity.
- Energía del USB: Connect the provided USB-C cable to the scale's USB-C port and plug the other end into a compatible USB power source (e.g., a wall adapter, computer USB port). The scale can operate without batteries when connected via USB.

Image: The scale can be powered by AAA batteries or a USB-C cable.
2 Colocación
Place the scale on a stable, flat, and level surface. Avoid areas with vibrations, drafts, or extreme temperature changes, as these can affect accuracy. Ensure the clear protective cover is properly positioned to shield the weighing pan from air currents.
Instrucciones de funcionamiento
1. Encendido y apagado
Presione el botón "ENCENDIDO/APAGADO" button to turn the scale on. Press and hold the "ENCENDIDO/APAGADO" button to turn the scale off. The scale will automatically shut off after a period of inactivity to conserve power.
2. Conversión de unidades
Presione el botón "MODO" button to cycle through the available weighing units: grams (g), ounces (oz), troy ounces (ozt), pennyweights (dwt), carats (ct), and grains (gn). The selected unit will be displayed on the screen.

Image: The scale's display indicating various weighing units.
3. Función de tara
The tare function allows you to subtract the weight of a container, so you only measure the net weight of its contents.
- Place the empty container (e.g., weighing pan) on the scale's platform.
- Espere a que la lectura se estabilice.
- Presione el botón "TARA" button. The display will reset to 0.000g.
- Agregue los artículos que desea pesar al contenedor. La pantalla mostrará solo el peso neto.

Image: Visual guide for using the Tare function.
4. Calibración
Regular calibration ensures the accuracy of your scale. Use the included 20g calibration weights.
- Turn on the scale and wait for it to stabilize at 0.000g.
- Mantenga presionada la tecla "MODO" button for approximately 6 seconds until the display flashes "20.000".
- Place one 20g calibration weight on the center of the weighing platform. The display will then flash "40.000".
- Place the second 20g calibration weight on the platform alongside the first.
- The display will show "PASS" and then return to normal weighing mode, indicating successful calibration. Remove the weights.

Image: Step-by-step instructions for calibrating the scale.
5. Pieces Counting (PCS) Function
Esta función le permite contar varios artículos del mismo peso.
- Turn on the scale and ensure it is in weighing mode.
- Colocar comoample quantity of items (e.g., 25, 50, 75, or 100 pieces) on the platform.
- Mantenga presionada la tecla "piezas" button until "PCS" appears on the display.
- Presione el botón "MODO" button to select the sample quantity you placed (e.g., "25 PCS").
- Presione el botón "piezas" button again to confirm. The scale is now calibrated for counting.
- Add more items to the platform, and the display will show the total count.
- To exit counting mode, press the "piezas" botón.
Mantenimiento
- Limpieza: Limpie la báscula con un paño suave yamp Paño. No utilice limpiadores abrasivos ni sumerja la báscula en agua.
- Almacenamiento: Store the scale in a clean, dry environment. Keep the protective cover closed when not in use to prevent dust and debris from affecting the weighing mechanism.
- Reemplazo de batería: Si utiliza baterías, reemplácelas cuando aparezca el indicador de batería baja en la pantalla.
- Tratar con cuidado: Avoid dropping the scale or subjecting it to sudden shocks, as this can damage the precision sensors.
Solución de problemas
| Problema | Posible causa | Solución |
|---|---|---|
| La báscula no se enciende. | Baterías bajas o agotadas; sin alimentación USB. | Replace batteries or connect to a stable USB power source. |
| Lecturas inexactas. | Not calibrated; unstable surface; drafts; overload. | Perform calibration; place on a stable, level surface; avoid drafts; ensure weight is within capacity. |
| Se muestra "O_Ld" o "EEEE". | Sobrecarga. | Retire el exceso de peso inmediatamente. No exceda los 100 g de capacidad. |
| Display is unstable or fluctuates. | Vibrations; air currents; electromagnetic interference. | Move scale to a more stable location; close protective cover; keep away from electronic devices. |
Presupuesto
| Característica | Detalle |
|---|---|
| Capacidad | 100 gramos |
| Legibilidad | 0.001 gramos |
| Unidades de pesaje | g, oz, ozt, dwt, ct, gn |
| Mostrar | LCD retroiluminado |
| Funciones | Tare, PCS (Counting), Auto Shut Off |
| Fuerza | 2 x AAA Batteries (included) or USB-C (cable included) |
| Material | Acrilonitrilo butadieno estireno (ABS) |
| Peso del artículo | 171 gramos |
| Dimensiones (aprox.) | 4.8" (L) x 2.7" (W) x 1.7" (H) (based on image 61OehI5dFvL) |

Image: Approximate dimensions of the scale.
Aplicaciones
The MAXUS Gold Milligram Scale D205 is versatile and can be used for various precision weighing tasks:
- Jewelry and precious metals
- Powders and fine ingredients
- Reloading components
- Uso en laboratorio
- Hobby and craft projects

Imagen: Examples of items that can be weighed with the scale.
Atención al cliente
For further assistance or inquiries, please contact MAXUS customer support. Refer to the product packaging or the official MAXUS websitio para detalles de contacto.