DeWin GC-03

DeWin GC-03 Multifunction Radiation Detector User Manual

Model: GC-03 | Brand: DeWin

1. Introducción

The DeWin GC-03 is a versatile 3-in-1 detector designed for the simultaneous measurement of electric fields, magnetic fields, and nuclear radiation. This device provides comprehensive environmental monitoring with a user-friendly interface and robust alarm features.

DeWin GC-03 Multifunction Radiation Detector showing its 3-in-1 capabilities and key features.

Image: The DeWin GC-03 detector, highlighting its 3-in-1 functionality for electric, magnetic, and nuclear radiation detection, along with features like 1500mAh battery and alarm modes.

2. Características principales

  • Multifunctional 3-in-1 Detection: Measures electric fields (1V/m to 1999V/m), magnetic fields (0.01µT to 99.99µT), and nuclear radiation (0.01µSv/h to 999.99µSv/h).
  • Adjustable Automatic Alarm: Features a customizable alarm threshold with triple alerts (audible, visual, vibrating) for immediate notification of hazardous conditions.
  • Modo de grabación de curvas: Displays real-time radiation variations over a cycle and stores up to 50 records of limit exceedances for later analysis.
  • 2.4-inch Backlit Color Screen: High-resolution display with adjustable backlight ensures clear visibility of data in various lighting conditions.
  • Batería de larga duración de 1500 mAh: Integrated high-capacity battery provides over 12 hours of standby time and is conveniently rechargeable via a Type-C port.
DeWin GC-03 detector showing visual, audible, and vibration alarm modes.

Image: The DeWin GC-03 detector illustrating its three customizable alarm modes: visual, red LED flash, and audible alerts.

DeWin GC-03 detector used for nuclear, electric, and magnetic field detection in various environments.

Image: Applications of the DeWin GC-03, demonstrating its use for detecting nuclear radiation, electric fields (near laptops and microwaves), and magnetic fields (near refrigerators).

3. Configuración inicial

3.1 Carga del dispositivo

Before first use, fully charge the GC-03 detector using the provided Type-C USB cable. Connect the cable to the device's Type-C port and a compatible USB power adapter (not included). The battery indicator on the screen will show charging status.

3.2 Encendido y apagado

  • To power on: Press and hold the power button (usually located on the side or top) until the screen illuminates.
  • Para apagar: mantenga presionado el botón de encendido hasta que el dispositivo se apague.

3.3 Configuración básica

Upon powering on, you may need to adjust basic settings such as language, date, and time. Navigate through the menu using the rotary knob and selection buttons. Refer to the 'Operating' section for detailed navigation instructions.

4. Instrucciones de funcionamiento

Selección de 4.1 modos

The GC-03 features a smooth rotary knob for easy navigation and mode selection. Rotate the knob to switch between Electric Field (EF), Magnetic Field (MF), and Nuclear Radiation detection modes. Press the 'OK' button to confirm your selection.

DeWin GC-03 detector showing rotary knob control and various measurement displays.

Image: The DeWin GC-03's intuitive rotary knob control, demonstrating how to switch between different measurement displays for radiation, electric, and magnetic fields.

4.2 Toma de medidas

  • Campo eléctrico: Select EF mode. Hold the device in the area you wish to measure. The screen will display the electric field strength in V/m.
  • Campo magnético: Select MF mode. Hold the device in the area you wish to measure. The screen will display the magnetic field strength in µT.
  • Radiación nuclear: Select Nuclear mode. The device will continuously monitor for α, β, γ, and X-rays. Readings will be displayed in µSv/h.

4.3 Configuración de alarma

Para ajustar los umbrales de alarma:

  1. Navigate to the 'Alarm Settings' menu using the rotary knob.
  2. Select the desired field (Electric, Magnetic, or Nuclear) to set its alarm threshold.
  3. Adjust the value using the navigation buttons and confirm with 'OK'.
  4. When a measurement exceeds the set threshold, the device will activate audible, visual (screen flash), and vibration alarms.

4.4 Curve Recording

The curve recording mode allows you to visualize changes in radiation levels over time. To activate and review:

  1. In Nuclear Radiation mode, navigate to the 'Curve Recording' option.
  2. Activate recording. The device will plot real-time radiation values on a graph.
  3. Para volverview past recordings or alarm history, access the 'History' menu. The device stores up to 50 records of limit exceedances.

4.5 Vídeo de demostración operativa

Video: This video demonstrates the key functions and user interface of the DeWin GC-03 Multifunction Radiation Detector, including navigation and measurement display.

5. Mantenimiento

5.1 Limpieza

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the screen or casing. Ensure no liquids enter the device.

5.2 Cuidado de la batería

The GC-03 is equipped with a built-in 1500 mAh rechargeable battery. For optimal battery life:

  • Recharge the device when the battery indicator is low.
  • Evite descargar completamente la batería con frecuencia.
  • Guarde el dispositivo en un lugar fresco y seco si no lo utiliza durante períodos prolongados.

6. Solución de problemas

ProblemaPosible causaSolución
El dispositivo no enciendeBatería baja; el botón de encendido no se presionó el tiempo suficienteCargue el dispositivo; mantenga presionado el botón de encendido durante 3 a 5 segundos
Lecturas inexactasInterferencia de otros dispositivos electrónicos; Dispositivo no calibradoMove away from other electronics; Refer to advanced settings for calibration options (if available) or contact support
La alarma no suenaAlarm volume too low; Alarm threshold not set correctly; Alarm disabledCheck volume settings; Adjust alarm thresholds; Ensure alarm is enabled in settings
La pantalla está oscura o ilegibleBacklight setting too low; Low batteryAdjust backlight brightness in settings; Charge the device

7. Especificaciones

CaracterísticaDetalle
ModeloGC-03
Tipos de detecciónElectric Field (EF), Magnetic Field (MF), Nuclear Radiation (α, β, γ, X-rays)
Nuclear Radiation Range0.01µSv/h to 999.99µSv/h
Rango de campo eléctricoDe 1 V/m a 1999 V/m
Rango de campo magnético0.01µT to 99.99µT
Mostrar2.4-inch High-Resolution Color Screen with adjustable backlight
Modos de alarmaAudible, Visual (LED flash), Vibration
Batería1500 mAh rechargeable (Type-C charging)
Tiempo de esperaMás de 12 horas
Dimensiones (L x An x Al)16 x 14 x 3.99 cm (aprox. 138 mm x 63 mm x 32 mm)
Peso218 gramos
Referencia del fabricanteRIYAREEDI-GS99549
DeWin GC-03 detector with dimensions labeled: 138mm height, 63mm width, 32mm depth.

Image: Dimensions of the DeWin GC-03 detector, showing its compact size.

Comparison table of DeWin GC-01, GC-02, and GC-03 models, highlighting GC-03's superior features.

Image: A comparison chart detailing the features of the GC-01, GC-02, and GC-03 models, emphasizing the GC-03's comprehensive detection capabilities and battery life.

8. Información de garantía

The DeWin GC-03 Multifunction Radiation Detector comes with a standard manufacturer's warranty. Please refer to the product packaging or the official DeWin website for specific warranty terms and conditions, including duration and coverage details. Keep your purchase receipt as proof of purchase for any warranty claims.

9. Soporte

For technical assistance, troubleshooting not covered in this manual, or general inquiries, please contact DeWin customer support. Contact information can typically be found on the official DeWin websitio o en el embalaje del producto.

Los recursos en línea y las preguntas frecuentes también pueden estar disponibles en las páginas de soporte del fabricante.

Copyright © 2026 DeWin. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.