Thank you for choosing the Duluth Forge DLS-N24T-2 Ventless Natural Gas Log Set. This product is designed to provide efficient supplemental heating and a realistic fireplace ambiance without the need for a chimney or vent. Please read this manual thoroughly before installation and operation to ensure safe and proper use.

Duluth Forge Ventless Natural Gas Log Set installed in a fireplace, showing realistic flames and logs.

Image 1: Duluth Forge DLS-N24T-2 Ventless Natural Gas Log Set in operation.

2. Información de seguridad

ADVERTENCIA: La instalación, el ajuste, la alteración, el servicio o el mantenimiento incorrectos pueden causar lesiones o daños materiales. Consulte este manual. Para obtener ayuda o información adicional, consulte a un instalador cualificado, una agencia de servicio técnico o la empresa de gas.

  • Este aparato es solo para uso en interiores.
  • Do not install this appliance in a bathroom or bedroom.
  • Asegúrese de que haya una ventilación adecuada en la habitación donde está instalado el aparato.
  • The appliance must be installed in a masonry or agency approved firebox.
  • Minimum firebox size required: 20 inches (H) x 28 inches (W) in front (23 inches W at rear) x 15 inches (D).
  • Equipped with an Oxygen Depletion Sensor (O.D.S.) that automatically shuts off the unit if oxygen levels drop.
  • Professional installation by a certified gas technician is highly recommended to ensure safety and maintain warranty validity.
  • Mantenga a los niños y a las mascotas alejados del aparato cuando esté en funcionamiento.
  • No coloque ropa u otros materiales inflamables sobre o cerca del aparato.

3. ¿Qué hay en la caja?

Verifique que todos los componentes estén presentes y sin daños antes de continuar con la instalación.

  • Chasis U-Burner - Cant. 1
  • Troncos de fibra cerámica pintados a mano - Cantidad 8
  • Bolsa de brasas - Cantidad 1
  • Paquete de hardware - Cantidad 1
  • User Manual - Qty. 1
Components of the Duluth Forge Ventless Gas Log Set, including the burner chassis, logs, and a bag of embers.

Imagen 2: Todos los componentes incluidos en el paquete.

4. Configuración

4.1 Firebox Preparation

Ensure your firebox meets the minimum size requirements: 20 inches (H) x 28 inches (W) in front (23 inches W at rear) x 15 inches (D). The firebox must be clean and free of debris.

Diagram showing the dimensions of the Duluth Forge Ventless Gas Log Set and the minimum required firebox dimensions.

Image 3: Product dimensions and minimum firebox requirements.

4.2 Conexión de la línea de gas

Connect the gas line to the U-burner chassis. This step requires a qualified gas technician to ensure proper and safe connection to your natural gas supply. Improper connection can lead to gas leaks and serious hazards.

4.3 Colocación de los troncos

Carefully arrange the 8 ceramic fiber logs on the burner chassis according to the diagram provided in the detailed user manual. The logs are designed to fit together like a puzzle, ensuring optimal flame appearance and heat distribution. Do not block any burner ports or air inlets.

Close-up of the Duluth Forge Ventless Gas Log Set showing the arrangement of the hand-painted ceramic logs and glowing embers.

Imagen 4: Detallada view of log placement and ember bed.

4.4 Ember Material Application

Distribute the glowing ember material from the provided bag evenly over the burner pan, avoiding direct contact with the burner ports. This enhances the realistic glowing effect.

4.5 Instalación de la batería

Install 1 AAA battery (included) into the battery-assisted Piezo ignition system. Refer to the manual for the exact location of the battery compartment.

5. Operación

5.1 Encendido

To ignite the log set, turn the control knob to the 'PILOT' position and press it in. While holding, press the Piezo igniter button repeatedly until the pilot flame ignites. Continue to hold the control knob for approximately 60 seconds to allow the thermocouple to heat up. Release the knob; if the pilot extinguishes, repeat the process. Once the pilot is stable, turn the control knob to the desired heat setting (1-5).

Close-up of the thermostat control knob and electronic Piezo ignition button on the Duluth Forge gas log set.

Image 5: Thermostat control and Piezo ignition.

5.2 Control termostático

The DLS-N24T-2 features a built-in thermostat control. Once set to a desired temperature, the burner will automatically cycle on and off to maintain the room temperature, providing consistent and efficient heating.

5.3 salida de calor

This unit provides 33,000 BTU of heat, capable of heating up to 1,300 sq. ft. It operates on natural gas, offering 99.9% efficiency without the need for an outside duct or chimney.

Duluth Forge Ventless Gas Log Set heating a large area, highlighting its 33,000 BTU output and ventless design.

Image 6: Efficient heating for large areas.

5.4 Apagado

To turn off the appliance, rotate the control knob to the 'OFF' position. For extended periods of non-use, it is recommended to turn off the main gas supply valve.

6. Mantenimiento

Regular maintenance ensures optimal performance and safety. Always turn off the appliance and allow it to cool completely before performing any maintenance.

6.1 Limpieza

  • Registros: Gently brush the ceramic logs with a soft brush to remove dust or soot. Do not use abrasive cleaners.
  • Burner/Pilot: Keep the burner ports and pilot assembly clean. Use a vacuum cleaner with a soft brush attachment to remove any lint or debris.
  • Exterior: Limpie las superficies exteriores con adamp paño.

6.2 Inspección anual

It is recommended to have a qualified service technician inspect the appliance annually. This includes checking gas connections, burner operation, pilot assembly, and the Oxygen Depletion Sensor (O.D.S.) for proper function.

7. Solución de problemas

If you encounter issues with your gas log set, refer to the following common problems and solutions. For persistent problems, contact a qualified service technician.

ProblemaPosible causaSolución
El piloto no se enciendeNo gas supply; Air in gas line; Pilot orifice clogged; Faulty igniterCheck gas supply; Bleed air from line; Clean pilot orifice; Replace igniter (if faulty)
El quemador principal no enciendePilot not lit; Thermostat setting too low; Main burner orifice cloggedLight pilot; Adjust thermostat; Clean main burner orifice
La unidad se apaga inesperadamenteOxygen Depletion Sensor (O.D.S.) activated; Pilot flame too weak; Insufficient ventilationEnsure adequate ventilation; Clean pilot assembly; Contact service technician if O.D.S. repeatedly activates
Olores inusualesNew unit burn-off; Gas leakInitial odors are normal; If gas odor persists, turn off gas supply and call gas company immediately

8. Especificaciones

CaracterísticaDetalle
Nombre del modeloDLS-N24T-2
MarcaFragua de Duluth
Tipo de combustibleGas natural
Salida de calor33,000 BTU
Cobertura de calefacciónHasta 1,300 pies cuadrados
Tipo de ventilaciónSin ventilación
Material de registroFibra cerámica
Tipo de igniciónPiezo asistido por batería (1 batería AAA incluida)
Tipo de controlControl del termostato
Dimensiones del producto24" de profundidad x 12" de ancho x 11" de alto
Peso del artículo50 libras
Características de seguridadOxygen Depletion Sensor (O.D.S.), Automatic Shut-off
CertificacionesSistema certificado por ANSI, aprobado por PFS

9. Garantía y soporte

9.1 Garantía limitada

This Duluth Forge gas log set comes with a limited warranty. Please refer to the warranty card included in your hardware pack for specific terms, conditions, and duration. Note that the warranty may be voided if the product is not installed by a qualified professional.

9.2 Atención al cliente

For technical assistance, replacement parts, or warranty claims, please contact Duluth Forge customer service. Contact information can be found on the product packaging or the official Duluth Forge websitio.

10. Vídeos oficiales del producto

Duluth Forge Ventless Gas Logs, Stacked 2022

This video showcases the Duluth Forge Ventless Gas Logs in a stacked configuration, highlighting their realistic appearance and flame patterns. It provides a visual demonstration of the product's aesthetic appeal.

Duluth Forge Ventless Dual Fuel Gas Log Set - 30 in. Berkshire Split Oak - Remote Control

This video demonstrates the Duluth Forge Ventless Dual Fuel Gas Log Set, featuring a Berkshire Split Oak design and remote control functionality. While a different size and fuel option, it illustrates the general operation and visual quality of Duluth Forge ventless gas logs.

© 2026 Duluth Forge. Todos los derechos reservados.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.