SINOTIMER SVP719-1-63A

SINOTIMER SVP719 120VAC 63A Adjustable VoltagManual del usuario del relé protector contra sobretensiones

1. Producto terminadoview

The SINOTIMER SVP719 is a 3-in-1 adjustable voltage surge protector relay designed for single-phase 120VAC systems. It integrates over-voltage protección, bajo voltage protection, current limiting, and energy metering functions. This device features three digital LED displays for real-time monitoring of voltage, current, and energy consumption (kWh). It is equipped with automatic recovery capabilities, ensuring electrical equipment protection by cutting off power during abnormal conditions and automatically restoring it when parameters return to normal. The unit is designed for easy installation on a universal DIN 35mm standard guide rail.

Frente view of the SINOTIMER SVP719 Adjustable Voltage Surge Protector with LED displays.

Frente view of the SINOTIMER SVP719 Adjustable Voltage Surge Protector.

Detailed product information diagram of the SINOTIMER SVP719 showing input/output, LED displays for voltage, current, kilowatt-hour, and control buttons.

Detailed diagram of the SVP719 showing displays and controls.

2. Información de seguridad

Lea atentamente todas las instrucciones de seguridad antes de instalar y utilizar el producto. El incumplimiento de estas instrucciones podría provocar una descarga eléctrica, un incendio o lesiones graves.

  • La instalación solo debe ser realizada por personal calificado.
  • Ensure the main power supply is disconnected before any wiring or maintenance.
  • Verifique el vol. correctotage and current ratings for your application.
  • No opere el dispositivo en mojado o damp condiciones.
  • No intente reparar ni modificar el dispositivo. Contacte con personal de servicio técnico cualificado.

3. Configuración e instalación

The SVP719 is designed for easy installation on a standard 35mm DIN rail. Follow the wiring diagram below for proper connection.

3.1 Montaje

Mount the device securely onto a 35mm DIN rail within an electrical enclosure.

3.2 conexiones de cableado

Connect the device according to the provided wiring diagram. Ensure all connections are tight and secure to prevent loose contacts and potential hazards.

  • N Input: Connect the neutral wire from the power source.
  • L Input: Connect the live wire from the power source.
  • N Output: Connect the neutral wire to the load.
  • L Output: Connect the live wire to the load.
Wiring diagram for the SINOTIMER SVP719 Adjustable Voltage Surge Protector, illustrating connections to power switch and air circuit breaker.

Wiring Diagram for SVP719.

4. Instrucciones de funcionamiento

The SVP719 features three LED displays and four control buttons for monitoring and configuration.

4.1 Pantallas LED

  • VolumentagPantalla electrónica (V): Muestra el volumen en tiempo realtage del circuito.
  • Pantalla actual (A): Shows the real-time current flowing through the circuit.
  • Kilowatt-hour Display (kWh): Shows the accumulated energy consumption.

4.2 botones de control

  • Botón de ajuste: Used to enter the parameter setting mode and cycle through different adjustable parameters.
  • Botón de flecha hacia arriba: Used to increase the value of a selected parameter.
  • Botón de flecha hacia abajo: Used to decrease the value of a selected parameter.
  • Botón ON/OFF: Used to manually turn the power supply to the load ON or OFF.

4.3 Manual ON/OFF Operation

Presione el ENCENDIDO/APAGADO button to manually switch the power to the connected load. The display will show 'OFF' when power is disconnected and 'ON' when connected.

4.4 Kilowatt-hour (kWh) Reset

To reset the accumulated Kilowatt-hour (kWh) reading, press the Flecha hacia abajo y COLOCAR buttons simultaneously. The kWh display will reset to 000.0.

This video demonstrates the key features and operation of the SINOTIMER SVP719, including parameter adjustment, over-voltage protección, bajo voltage protection, and manual ON/OFF control.

5. Configuración de parámetros

The SVP719 allows for adjustment of various protection parameters. All parameters are adjustable within specified ranges.

5.1 Entering Setting Mode

Mantenga pulsado el COLOCAR button for approximately 3 seconds to enter the parameter setting mode. The first adjustable parameter will appear on the display.

5.2 Cycling Through Parameters

Once in setting mode, short press the COLOCAR button to cycle through the parameters sequentially. Each press will display the next parameter.

5.3 Adjusting Parameter Values

When a desired parameter is displayed, use the Flecha hacia arriba y Flecha hacia abajo buttons to adjust its value. The display will flash while adjusting.

5.4 Saving Settings and Exiting

After adjusting a parameter, wait for approximately 5 seconds without pressing any button. The device will automatically save the new setting and exit the setting mode, returning to normal operation.

5.5 Parámetros ajustables

  • U> (Over-voltage Protection Value): Establece el volumen superiortage limit. If the voltage exceeds this value, the protector will trip.
  • U< (Under-voltage Protection Value): Establece el volumen más bajotage limit. If the voltage drops below this value, the protector will trip.
  • I> (Over-current Protection Value): Sets the maximum current limit. If the current exceeds this value, the protector will trip.
  • t-on (Fault Recovery Delay Time): Sets the delay before the device automatically reconnects after a fault (over/under voltage, over-current) has cleared.
  • t-off (Reset/Start Delay): Sets the delay for initial power-on or manual reset.
  • CAL-A (Current Calibration): Allows for fine-tuning of the current measurement.
  • CAL-V (Voltage Calibración): Allows for fine-tuning of the voltagy medición.
  • CLP (Clear kWh): Resets the energy consumption counter.

6. Funciones de protección

The SVP719 provides robust protection for your electrical equipment.

6.1 sobrevol.tage Protección

When the circuit voltage excede el sobrevol establecidotage protection value (U>), the protector will instantaneously cut off the power supply to prevent damage to connected devices. The display will indicate an over-voltagy condición.

6.2 Bajo volumentage Protección

If the circuit voltage drops below the set under-voltage protection value (U<), the protector will immediately disconnect the power. The display will indicate an under-voltagy condición.

6.3 Protección contra sobrecorriente

Should the current drawn by the load exceed the set over-current protection value (I>), the device will trip and cut off power to protect the circuit and load.

6.4 Recuperación automática

After a fault condition (over-voltage, bajo voltage, or over-current) has been detected and the power supply is cut off, the SVP719 will continuously monitor the circuit. Once the voltage and current return to normal operating ranges for the duration of the set recovery delay time (t-on), the protector will automatically restore power to the load.

7. Mantenimiento

To ensure optimal performance and longevity of your SVP719, follow these simple maintenance guidelines:

  • Inspeccione periódicamente el dispositivo para detectar cualquier signo de daño físico o conexiones sueltas.
  • Mantenga el dispositivo limpio y libre de polvo y residuos. Utilice un paño seco y suave para limpiarlo.
  • No utilice limpiadores abrasivos ni disolventes.
  • Asegúrese de que haya una ventilación adecuada alrededor del dispositivo para evitar el sobrecalentamiento.

8. Solución de problemas

If you encounter issues with your SVP719, refer to the following common problems and solutions:

ProblemaPosible causaSolución
El dispositivo no se enciendeNo input power; incorrect wiringCheck main power supply; verify wiring connections as per diagram.
La energía se corta con frecuenciaVolumentage/current outside set limits; sensitive settingsVerificar el volumen realtage/current; adjust protection parameters (U>, U<, I>) to appropriate levels for your load.
El dispositivo no se recupera automáticamenteFault condition still present; recovery delay too longAsegúrese de voltage/current has returned to normal; check and adjust 't-on' recovery delay setting.
kWh reading is inaccurateCalibración necesariaRealizar mediciones de corriente y vol.tage calibration (CAL-A, CAL-V) if you have a reference meter.

9. Especificaciones

Technical specifications for the SINOTIMER SVP719-1-63A model:

Lado view of the SINOTIMER SVP719 showing technical specifications printed on the casing.

Technical specifications printed on the device casing.

CaracterísticaEspecificación
MarcaSINOTIMADOR
Número de modeloSVP719-1-63A
Volumentage120 Voltios AC
Corriente máxima63 Amps
Número de puntos de venta1
Característica especialSurge Protection, Over-voltagProtección electrónica, subvol.tage Protection, Current Limiting, Energy Metering
Tipo de enchufe de alimentaciónTipo A - 2 pines (Norteamérica)
InstalaciónRiel guía estándar DIN 35 mm
Código Postal607606586190

10. Garantía y soporte

The SINOTIMER SVP719-1-63A comes with a 1 año de garantía del fabricante.

For technical support, warranty claims, or further assistance, please contact SINOTIMER customer service through their official channels or the retailer from whom the product was purchased. Please have your product model number (SVP719-1-63A) and purchase details ready when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.