Wattive UHEHBCEAH-3B41A594

Wattive 4KW VFD Inverter: 220V Single-Phase Input to 380V Three-Phase Output User Manual

Model: UHEHBCEAH-3B41A594 | Brand: Wattive

1. Producto terminadoview

The Wattive 4KW Variable Frequency Drive (VFD) Inverter is designed for converting 220V single-phase AC input to 380V three-phase AC output, providing precise speed control for various industrial applications. This device features advanced control algorithms and robust protection mechanisms to ensure reliable and efficient operation.

  • High-Precision Vector Control: Utilizes an advanced VF/vector control algorithm for superior load capacity, powerful control, strong torque, and dynamic performance across a wide speed range. The corrosion-resistant PCB coating ensures stable operation in challenging environments (high temperature, humidity, dust).
  • Protección integral: Integrated protection functions guard against overcurrent, overvoltage, bajo volumentage, overload, and phase loss. It also supports fault logging to reduce maintenance costs and ensure stable operation.
  • Interfaz fácil de usar: Equipped with a high-resolution LED LCD display for clear monitoring of motor operating status. Supports an external keyboard with a 2-meter extension cable for enhanced convenience and flexibility.
  • Disipación de calor eficiente: Features a silent, high-speed fan and a separate air duct for powerful heat dissipation, ensuring long-term stable operation. The housing is made from flame-retardant ABS plastic, offering high impact resistance, high-temperature resistance, and excellent flame-retardant properties for improved safety.
  • Amplia gama de aplicaciones: Ideal for motor drive equipment such as fans, water pumps, CNC machine tools, ball mills, injection molding machines, crushers, conveyor belts, and compressors.
Wattive 4KW VFD Inverter with key features highlighted: Energy Saving, LED display screen, Multiple Protection, Easy to use.
Figure 1.1: Wattive 4KW VFD Inverter highlighting its main features.

2. Información de seguridad

Please read and understand all safety instructions before installing, operating, or maintaining the VFD inverter. Failure to follow these instructions may result in electric shock, injury, or equipment damage.

  • Riesgo de descarga eléctrica: Este dispositivo funciona con alto volumen.tages. Always disconnect power before performing any installation, wiring, or maintenance.
  • Descarga del condensador: Wait at least 10 minutes after disconnecting power for DC bus capacitors to discharge before touching any internal components.
  • Puesta a tierra adecuada: Ensure the inverter is properly grounded according to local electrical codes and standards. Improper grounding can lead to electric shock.
  • Terminales de salida: Do not connect power to the output terminals (U, V, W). These terminals are for motor connection only.
  • Personal calificado: Installation and maintenance should only be performed by qualified electrical personnel.
  • Condiciones ambientales: Operate the inverter within specified environmental conditions to prevent damage and ensure safety.
Wattive 4KW VFD Inverter showing comprehensive protection features: Undervoltage, Sobrevol.tage, Overcurrent, Overload, Short circuit, Phase loss, Overheating, Ground, Stall Protection.
Figure 2.1: Comprehensive protection features of the VFD Inverter.

3. Especificaciones

Technical specifications for the Wattive 4KW VFD Inverter:

ParámetroValor
MarcaWattive
Número de modeloUHEHBCEAH-3B41A594
Potencia nominal4000 Watt (4KW)
Vol. De entrada nominaltageSingle-Phase 220V (AC)
Vol. De salida nominaltageThree-Phase 380V (AC)
Frecuencia nominal50/60 Hz
Rango de frecuencia de salida0-320 Hz
Corriente de salida8.5A
Dimensiones del producto (L x An x Al)24 de largo x 24 de ancho x 17.8 de alto cm
MaterialABS Flame Retardant Plastic
Método de enfriamientoVentilador de disipación de calor
Usos recomendadosCNC machine tools, fans, pumps, injection molding machines, crushers, conveyor belts, compressors
Dimensions and specifications of the Wattive 4KW VFD Inverter.
Figura 3.1: Dimensiones del producto y especificaciones clave.

4. Configuración e instalación

4.1 Instrucciones de cableado

Proper wiring is critical for the safe and correct operation of the VFD inverter. Refer to the wiring diagrams below and ensure all connections are secure and comply with local electrical regulations.

  • Input Power (Single-Phase 220V): Connect the single-phase 220V AC power supply to the designated input terminals.
  • Motor Connection (Three-Phase 380V): Connect your three-phase 380V motor to the output terminals (U, V, W).
  • Toma de tierra: Always connect the earth wire to the designated grounding terminal.
  • Resistencia de frenado: The machine has a built-in braking resistor. An external braking resistor can be connected at the P+/PB position if required for specific applications.
Wiring diagram for 380V Inverter, showing connections for single-phase 220V power supply, three-phase 380V motor, and earth wire.
Figure 4.1: Basic wiring diagram for the VFD Inverter.
Technical wiring diagram for the Wattive VFD Inverter, showing connections for single-phase power, contactor, three-phase induction motor, programmable relay, analog inputs/outputs, and RS485 communication.
Figure 4.2: Detailed technical wiring diagram.

4.2 Instalación del panel de control

The control panel of the VFD inverter can be easily removed and installed remotely using the provided 2-meter extension cable. This offers flexibility in mounting the display for convenient access and monitoring.

  • To remove the panel, gently unclip it from the main unit.
  • Connect the extension cable to the panel and the main unit.
  • Mount the panel in a desired location using appropriate fasteners (not included).
Wattive VFD Inverter with its control panel detached, illustrating that the panel can be freely removed and connected via a 2-meter cable.
Figure 4.3: Detachable control panel with 2-meter extension cable.

5. Instrucciones de funcionamiento

The VFD inverter features an intuitive control panel for easy operation and parameter adjustment.

5.1 Panel de control terminadoview

Detallado view of the Wattive VFD Inverter's operation interface, showing the LED display and control buttons (PRG, FUNC, Shift, Run, Stop, Enter, Up, Down).
Figure 5.1: VFD Inverter operation interface.
  • Pantalla LED: Shows current operating frequency, input voltage, y otros parámetros.
  • PRG (Program) Key: Entra/sale del modo de configuración de parámetros.
  • FUNC (Function) Key: Used for various function selections.
  • Shift Key (>>): Cambia la posición del cursor durante la edición de parámetros.
  • Up/Down Keys (▲/▼): Adjusts parameter values or navigates menus.
  • Introducir clave: Confirma selecciones o cambios de parámetros.
  • Tecla EJECUTAR: Inicia el funcionamiento del motor.
  • Tecla DETENER: Detiene el funcionamiento del motor.

5.2 Configuración de parámetros básicos

The VFD allows for adjustment of various parameters to suit specific motor and application requirements. Key parameter groups include:

  • F00: Basic Operating Parameters: Includes fundamental settings like maximum frequency, acceleration/deceleration times.
  • F01: Start/Stop Control Parameters: Settings related to motor start and stop behavior.
  • F02: Motor Parameters: Specific motor data such as rated voltage, corriente y frecuencia.
  • F03: Reserved Parameters: Additional or advanced settings.

To adjust speed, simply use the rotary dial or the Up/Down keys on the control panel. The LED display provides real-time feedback on the motor's operating status.

Dial for speed adjustment on the Wattive VFD Inverter, showing how to adjust speed with a twist.
Figure 5.2: Adjusting motor speed with the control dial.

6. Mantenimiento

Regular maintenance ensures the longevity and optimal performance of your Wattive VFD Inverter.

  • Limpieza: Periodically clean the exterior of the inverter to prevent dust accumulation, especially around the cooling fan and ventilation openings. Use a soft, dry cloth. Do not use liquid cleaners.
  • Sistema de enfriamiento: Ensure the cooling fan is free from obstructions and operating correctly. The independent air duct design helps maintain efficient heat dissipation.
  • Conexiones: Regularly check all electrical connections for tightness and signs of corrosion. Loose connections can lead to overheating or malfunction.
  • Comprobación ambiental: Ensure the operating environment remains within specified temperature and humidity ranges. The corrosion-resistant PCB coating provides protection in harsh conditions, but extreme environments should be avoided.
  • Inspección: Visually inspect the inverter for any signs of damage, discoloration, or unusual odors.
Trasero view of the Wattive VFD Inverter, highlighting the high-speed cooling fan for efficient heat dissipation.
Figure 6.1: High-speed cooling fan for efficient heat dissipation.
Three feature cards for the Wattive VFD Inverter: High-speed fan, ABS flame retardant material, and LED display.
Figure 6.2: Key features including high-speed fan and flame-retardant housing.

7. Solución de problemas

The VFD inverter is equipped with comprehensive protection functions that can help diagnose and prevent issues. If you encounter problems, refer to the following general troubleshooting steps:

  • Códigos de error: The LED display will show specific error codes if a fault occurs (e.g., overcurrent, overvoltage, bajo volumentage, overload, phase loss). Consult the full product manual for a complete list of error codes and their remedies.
  • Fuente de alimentación: Verify that the input power supply is stable and within the specified voltagrango e (220 V CA).
  • Conexión del motor: Check that the motor is correctly wired to the output terminals (U, V, W) and that there are no loose connections.
  • Sobrecarga: If an overload error occurs, check the motor's load and ensure it does not exceed the inverter's capacity. Reduce the load or adjust motor parameters if necessary.
  • Calentamiento excesivo: Ensure adequate ventilation around the inverter and that the cooling fan is operating. Clear any obstructions to airflow.
  • Toma de tierra: Confirm that the inverter is properly grounded.
  • Fault Logging: The inverter supports fault logging, which can provide historical data on issues. This information can be useful for diagnosing intermittent problems.

If the problem persists after performing these checks, contact customer support for further assistance.

8. Aplicaciones

The Wattive 4KW VFD Inverter is versatile and suitable for a wide range of industrial motor drive applications, including but not limited to:

  • Máquinas herramientas CNC
  • Fans and Ventilation Systems
  • Bombas de agua
  • Injection Molding Machines
  • Crushers and Grinders
  • Cintas transportadoras
  • Compresores de aire
  • Molinos de bolas
Collage of industrial applications for the Wattive VFD Inverter, including motor, water pump, fan, air compressor, and conveyor belt.
Figura 8.1: Examples of industrial applications.

9. Garantía y soporte

Wattive products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase or visit the official Wattive website. Please have your model number (UHEHBCEAH-3B41A594) and purchase date ready when contacting support.

© 2023 Wattive. All rights reserved.

Ask a question about this manual