OWON OW3070/OW3100/OW3200/OW3300/P4100

Manual del usuario de las sondas del osciloscopio digital OWON

Models: OW3070, OW3100, OW3200, OW3300, P4100

Marca: OWON

1. Introducción

This manual provides essential information for the safe and effective use of your OWON Digital Oscilloscope Probes. These probes are designed for use with compatible digital oscilloscopes, such as the OWON XDS and HDS200 series, to accurately measure electrical signals. Please read this manual thoroughly before use.

2. Información de seguridad

Observe siempre las siguientes precauciones de seguridad para evitar lesiones y daños al equipo:

  • No exceda el volumen máximo de entradatage ratings specified for your probe model.
  • Ensure the probe's ground lead is properly connected to the circuit's ground before making any measurements.
  • Use only the accessories provided or approved by OWON.
  • Inspect the probe and cables for any damage before each use. Do not use damaged equipment.
  • Avoid touching exposed circuit components when the circuit is powered.
  • Always disconnect the probe from the circuit before disconnecting it from the oscilloscope.
  • The probes are designed for 'Electrical' DIY Supplies and are CE certified.

3. Contenido del paquete

Your OWON oscilloscope probe package typically includes the following items:

  • Oscilloscope Probe (e.g., OW3070, OW3100, OW3200, OW3300, or P4100)
  • Ground Lead with Alligator Clip
  • Probe Hook Tip
  • Protective Cap for Probe Tip
  • Color Rings (for channel identification)
  • Adjustment Tool (for probe compensation)
Diagram of oscilloscope probe components
Figure 1: Typical Oscilloscope Probe Components
Close-up of probe tip with protective cap
Figure 2: Probe Tip with Protective Cap

4. Producto terminadoview

OWON offers a range of digital oscilloscope probes designed for various measurement needs, compatible with OWON XDS and HDS200 series oscilloscopes. These probes provide different bandwidths and attenuation ratios to suit diverse applications.

OWON OW3200 200MHz Oscilloscope Probe with accessories
Figure 3: OWON OW3200 200MHz Oscilloscope Probe
OWON OW3100 100MHz Oscilloscope Probe with accessories
Figure 4: OWON OW3100 100MHz Oscilloscope Probe
OWON OW3070 70MHz Oscilloscope Probe with accessories
Figure 5: OWON OW3070 70MHz Oscilloscope Probe
OWON P4100 High Voltage Sonda de osciloscopio
Figure 6: OWON P4100 High Voltage Sonda de osciloscopio
Chart showing various OWON passive probe models and their bandwidths
Figure 7: OWON Passive Probe Bandwidth Overview

El siguiente vídeo ofrece una visión generalview of a compatible OWON Digital Oscilloscope (XDS3104E), demonstrating features and typical usage scenarios where these probes would be employed.

Video 1: OWON XDS3104E Digital Oscilloscope Overview (compatible with these probes)

5. Configuración y conexión

  1. Conectar al osciloscopio: Align the BNC connector of the probe with the input channel of your oscilloscope and twist clockwise to secure it.
  2. Attach Ground Lead: Connect the ground lead's alligator clip to the ground terminal of your circuit under test. Ensure a solid connection.
  3. Seleccionar atenuación: Most OWON probes feature a 1X/10X attenuation switch. Set this switch to match the desired attenuation on your oscilloscope's input channel. For high voltage measurements, the P4100 probe offers 100X attenuation.
  4. Attach Probe Tip Accessories: Depending on your measurement needs, attach the probe hook tip for hands-free connection or use the protective cap for safety when not in use. Use color rings to identify different channels if using multiple probes.
Oscilloscope probe with ground lead connected
Figure 8: Probe with Ground Lead Attached

6. Operación

Once connected, ensure your oscilloscope's channel settings (e.g., voltage scale, coupling) are appropriate for the signal you are measuring and match the probe's attenuation setting. Always perform probe compensation before making critical measurements.

Compensación de la sonda

Probe compensation ensures accurate signal reproduction on the oscilloscope screen. This procedure typically involves:

  1. Connect the probe to an oscilloscope channel and attach the probe tip to the oscilloscope's probe compensation output (usually a square wave signal).
  2. Set the probe to 10X attenuation.
  3. Adjust the compensation trimmer on the probe (using the provided adjustment tool) until a flat-top square wave is displayed on the oscilloscope.

Refer to your oscilloscope's user manual for specific instructions on probe compensation.

7. Mantenimiento

  • Limpieza: Use a soft, dry cloth to clean the probe. Do not use abrasive cleaners or solvents. Ensure the probe is disconnected from all power sources before cleaning.
  • Almacenamiento: Store the probe in a clean, dry environment, away from extreme temperatures and humidity. Keep the protective cap on the probe tip when not in use.
  • Inspección: Regularly inspect the probe cable, connectors, and tip for any signs of wear or damage. Replace the probe if any damage is found.

8. Solución de problemas

  • No hay señal en la pantalla: Check if the probe is securely connected to both the oscilloscope and the circuit. Verify the oscilloscope channel is enabled and set to the correct input.
  • Forma de onda distorsionada: Perform probe compensation as described in Section 6. Ensure the attenuation setting on the probe matches the oscilloscope's channel setting. Check for damaged cables or connectors.
  • Ruido excesivo: Ensure the ground lead is properly connected. Minimize loop area between the probe tip and ground lead. Check for external electromagnetic interference.

9. Especificaciones

CaracterísticaOW3070OW3100OW3200OW3300P4100
Ancho de banda70 MHz100 MHz200 MHz300 MHz100 MHz
Hora de levantarse5 ns3.5 ns1.75 ns1.17 ns3.5 ns
Relación de atenuación1X/10X1X/10X1X/10X1X/10X100X
Resistencia de entrada1 MΩ/10 MΩ1 MΩ/10 MΩ1 MΩ/10 MΩ1 MΩ/10 MΩ100 MΩ
Capacitancia de entrada1X: 85-120pF
10X: 13-17pF
1X: 85-120pF
10X: 13-17pF
1X: 85-120pF
10X: 13-17pF
1X: 85-120pF
10X: 13-17pF
100X: 6pF
Rango de compensación10-35 pF10-35 pF10-35 pF10-35 pF10-35 pF
Vol. De entrada máx.tage1X: 300V CAT II
10X: 600V CAT II
1X: 300V CAT II
10X: 600V CAT II
1X: 300V CAT II
10X: 600V CAT II
1X: 300V CAT II
10X: 600V CAT II
2000V DC+Peak AC
Temperatura de funcionamiento0-50 °C0-50 °C0-50 °C0-50 °C0-50 °C
Humedad de funcionamiento0-80 % de humedad relativa0-80 % de humedad relativa0-80 % de humedad relativa0-80 % de humedad relativa0-80 % de humedad relativa
Longitud del cable120 centímetros120 centímetros120 centímetros120 centímetros120 centímetros
Peso50 gramos50 gramos50 gramos50 gramos65 gramos

10. Consejos para el usuario

  • For general-purpose measurements, the 10X attenuation setting is usually preferred as it reduces loading on the circuit and provides a wider voltage rango.
  • Always ensure the probe's ground connection is as short as possible to minimize inductance and noise pickup.
  • When measuring high-frequency signals, use the shortest possible ground lead to maintain signal integrity.
  • Utilize the color rings to easily distinguish between multiple channels when performing multi-channel measurements.

11. Garantía y soporte

For warranty information, technical support, or service inquiries, please contact OWON Instrumentation Store directly. Keep your purchase records for any warranty claims.

OWON Instrumentation Store


Osciloscopio digital de 4 canales OWON XDS3104E con AD de 8 bits de alta resolución

Osciloscopio digital de 4 canales OWON XDS3104E con AD de 8 bits de alta resolución

0:41 • 1280×720 • demostración de la función

Documentos relacionados - XDS3104E

Preview Guía rápida del osciloscopio portátil serie OWON HDS200
Esta guía rápida proporciona información esencial para el funcionamiento del osciloscopio portátil OWON serie HDS200. Abarca la certificación del producto, precauciones de seguridad, instrucciones detalladas para el uso del osciloscopio y las funciones del multímetro, el funcionamiento del generador de formas de onda, la resolución de problemas comunes y los procedimientos de mantenimiento.
Preview OWON HDS200 Serie Handheld-Oszilloskop Gebrauchsanweisung
Umfassende Gebrauchsanweisung für die OWON HDS200 Serie Handheld-Oszilloskope (HDS272, HDS242, HDS2102, HDS2202). Enthält Sicherheitshinweise, Bedienungsanleitungen, technische Daten und Garantieinformationen.
Preview Manual del usuario del osciloscopio portátil serie OWON HDS200: funcionamiento y especificaciones
Este completo manual de usuario proporciona instrucciones detalladas para el funcionamiento de los osciloscopios portátiles OWON HDS200 de doble canal, incluidos los modelos HDS272(S) y HDS242(S). Abarca información de seguridad, inspección general, funciones de osciloscopio, multímetro y generador de formas de onda opcional, además de especificaciones técnicas y pautas de mantenimiento.
Preview Osciloscopio Portatif Serie HDS200 - Guía Rápida
Esta guía rápida presenta el osciloscopio portátil OWON serie HDS200 para dos canales. Recoge la información de seguridad, el uso del osciloscopio y del multímetro, el generador de señales, la comunicación con el ordenador, el desplazamiento y los accesorios. Ideal para un premio principal rápido.
Preview Guía de inicio rápido del osciloscopio portátil de 2 canales de la serie OWON HDS200
Esta guía de inicio rápido proporciona información esencial para el funcionamiento de los osciloscopios portátiles de 2 canales de la serie OWON HDS200, incluidos los modelos HDS272, HDS242, HDS2102 y HDS2202. Abarca precauciones de seguridad, inspección general, uso del osciloscopio y multímetro, funciones del generador de señales, conectividad del software, resolución de problemas y mantenimiento.
Preview Guía rápida del osciloscopio portátil de doble canal OWON HDS200
Guía rápida del osciloscopio portátil OWON HDS200 de doble canal. Incluye información de seguridad, inspección general, uso del osciloscopio y multímetro, funciones del generador de formas de onda, resolución de problemas, mantenimiento y accesorios. Incluye los modelos HDS272(S), HDS242(S) y HDS2102(S).