AquaMiracle AP-40/AP-60/AP-80/AP-160

AquaMiracle Linear Air Pump Instruction Manual

Models: AP-40, AP-60, AP-80, AP-160

1. Introducción

Thank you for choosing the AquaMiracle Linear Air Pump. This manual provides essential information for the safe and efficient operation of your AP-40, AP-60, AP-80, or AP-160 model air pump. These pumps are designed for various applications requiring powerful and consistent aeration, including pond aeration, septic systems, hydroponics, aquariums, fish farms, and seafood restaurants.

Las características principales incluyen:

  • Super powerful air output and pressure.
  • Motor constructed with a full copper coil for high efficiency and low power consumption.
  • Multi-layer denoising design for quiet operation.
  • Expanded housing surface for efficient heat dissipation, ensuring optimal performance and extended lifespan.
AquaMiracle Linear Air Pump
Figure 1: AquaMiracle Linear Air Pump (Exampel modelo)

2. Instrucciones de seguridad

  • Lea todas las instrucciones cuidadosamente antes de operar la bomba.
  • Ensure the pump is placed on a stable, level surface in a dry, well-ventilated area.
  • Do not submerge the pump in water. It is not waterproof.
  • Asegúrese siempre que la fuente de alimentación coincida con el volumentage requirements specified on the pump's label.
  • Nunca opere la bomba con un cable de alimentación o enchufe dañado.
  • Mantenga la bomba alejada de los niños y las mascotas.
  • Desconecte la fuente de alimentación antes de realizar cualquier mantenimiento o limpieza.
  • For applications involving water, always use a check valve on the airline tubing to prevent water from siphoning back into the pump during a power outage.
  • No bloquee la entrada o salida de aire.

3. Contenido del paquete

Al desembalar, verifique que todos los artículos estén presentes y sin daños:

  • AquaMiracle Linear Air Pump (AP-40, AP-60, AP-80, or AP-160 model)
  • Air diffuser manifold (e.g., 8 outlets for AP-40/AP-60, 17 outlets for AP-80, 46 outlets for AP-160)
  • Adaptador de manguera
  • Manual de instrucciones

Note: Airline tubing and air stones are not included and must be purchased separately.

Air pump dimensions and accessories
Figure 2: Air pump dimensions and included accessories (manifold and hose adapter shown)

4. Especificaciones

The AquaMiracle Linear Air Pumps are available in several models, each with distinct performance characteristics:

Specifications table for AquaMiracle Air Pumps
Figure 3: Detailed specifications for AP-40, AP-60, AP-80, and AP-160 models.
Table 1: AquaMiracle Linear Air Pump Model Specifications
ModeloFuerzaSalida de airePresión del aireProfundidad máxima del aguaLongitud del cable de alimentaciónManifold Outlets
AP-4025 W635 GPH (40 LPM)0.028 MPa9.3 pies (2.8 m)6 pies8
AP-6030 W950 GPH0.028 MPa9.3 pies (2.8 m)6 pies8
AP-8040 W1350 GPH0.028 MPa9.3 pies (2.8 m)6 pies17
AP-160105 W2550 GPH0.042 MPa13.8 pies (4.2 m)6 pies46

Physical Dimensions (Approximate):

  • Longitud: 7.87 pulgadas
  • Ancho: 6.34 pulgadas
  • Altura: 6.89 pulgadas
  • Outlet Diameter (Outer): 0.69 inches (17.4 mm)
  • Outlet Diameter (Inner): 0.35 inches (8.8 mm)
  • Manifold Branch Diameter (Inner): 3/16 inches
  • Manifold Branch Diameter (Outer): 0.4 inches (10 mm)
  • Hose Adapter Diameter (Inner): 0.5 inches (12.8 mm)
  • Hose Adapter Diameter (Outer): 0.85 inches (21.5 mm)

5. Configuración e instalación

Follow these steps to set up your AquaMiracle Linear Air Pump:

  1. Colocación: Position the air pump on a flat, stable surface in a dry, well-ventilated area. Ensure it is above the water level of your pond, aquarium, or hydroponic system to prevent water from flowing back into the pump. If placing below water level, a check valve is mandatory.
  2. Connect Manifold: Attach the provided air diffuser manifold to the pump's air outlet.
  3. Connect Tubing and Air Stones: Connect appropriate airline tubing (not included) to each outlet on the manifold. Attach air stones (not included) to the other end of the tubing. Ensure all connections are secure to prevent air leaks.
  4. Submerge Air Stones: Place the air stones into the water at the desired depth.
  5. Conexión de energía: Once all connections are made and checked, plug the pump's power cord into a suitable electrical outlet.
Applications of AquaMiracle Air Pump
Figura 4: Examples of AquaMiracle Linear Air Pump applications.

6. Instrucciones de funcionamiento

Operating your AquaMiracle Linear Air Pump is straightforward:

  1. After completing the setup, plug the pump into a power outlet. The pump will start operating immediately.
  2. Observe the air stones in the water to ensure consistent bubble production.
  3. Adjust the placement of air stones as needed to achieve optimal aeration throughout your system.

7. Mantenimiento

El mantenimiento regular garantiza la longevidad y el rendimiento óptimo de su bomba de aire:

  • Cleaning Air Stones: Periodically check air stones for clogging due to algae or mineral buildup. Clean or replace them as necessary to maintain efficient air flow.
  • Carcasa de la bomba: Keep the exterior of the pump clean and free from dust and debris. This aids in efficient heat dissipation.
  • Filtro de aire: (If applicable) Some models may include an air filter. Check and clean or replace the air filter regularly according to the manufacturer's recommendations to prevent dust from entering the pump and reducing performance.
  • Componentes de caucho: Inspect the rubber gasket sealing and silicon feet for any signs of wear or damage. These components contribute to the pump's quiet operation and stability. Replace if necessary.
Internal components and noise reduction features of the air pump
Figura 5: Interna view highlighting noise reduction features like shock absorption rubber buffer, rubber gasket sealing, and silicon feet.

8. Solución de problemas

Si tiene problemas con su bomba de aire, consulte los siguientes problemas y soluciones comunes:

Tabla 2: Guía de resolución de problemas
ProblemaPosible causaSolución
Sin flujo de aire
  • La bomba no está enchufada o no tiene energía
  • Tubo de aire doblado o bloqueado
  • Piedras de aire obstruidas
  • Mal funcionamiento de la bomba
  • Verifique la conexión eléctrica y el tomacorriente.
  • Inspect and clear air tubing
  • Limpiar o reemplazar las piedras de aire
  • Contactar con atención al cliente
Flujo de aire bajo
  • Clogged air stones or tubing
  • Air leaks in connections
  • Componentes de la bomba desgastados
  • Clean or replace air stones/tubing
  • Apriete todas las conexiones
  • Contact customer support for diaphragm replacement (if applicable)
Ruido/vibración excesivos
  • Colocación inestable
  • Worn silicon feet or rubber buffer
  • Problema con componentes internos
  • Asegúrese de que la bomba esté sobre una superficie plana y estable.
  • Inspect and replace worn silicon feet/rubber buffer
  • Contactar con atención al cliente

9. Consejos para el usuario

  • Check Valve Importance: Always install a check valve on your airline tubing, especially if the pump is placed below the water level. This prevents water from back-siphoning into the pump and causing damage during power outages.
  • Aireación óptima: For large or irregularly shaped ponds/tanks, consider using multiple air stones distributed evenly to ensure comprehensive oxygenation.
  • Tubing Selection: Use high-quality, non-kinking airline tubing to maintain consistent air flow and prevent blockages.
  • Condiciones ambientales: While the pump is designed for durability, avoid exposing it to direct sunlight, extreme temperatures, or excessive humidity to prolong its lifespan.

10. Garantía y soporte

AquaMiracle products are manufactured to high-quality standards. For any questions, technical assistance, or warranty claims, please contact your retailer or the AquaMiracle customer support team. Please have your model number and purchase date available when contacting support.

Documentos relacionados - AP-40/AP-60/AP-80/AP-160

Preview AP instantáneo de Aruba 基本操作ガイド
Aruba instantáneo APデバイスの基本操作、設定、メンテナンス方法を解説する包括的なガイド。初期設定からSSID設定、ファームウェアアップデートまでを網羅.
Preview Instrucciones de cuidado y funcionamiento de las bombas de aire Danner serie AP | Uso en acuarios y estanques
Instrucciones completas de cuidado y funcionamiento para las bombas de aire Danner Serie AP, incluidos los modelos AP-20, AP-40, AP-60 y AP-100. Incluye características, instrucciones de instalación en interiores y estanques, y precauciones de seguridad importantes.
Preview Notas de la versión 8.12.0.3 del sistema operativo HPE Aruba Networking Instant
Este documento proporciona notas de lanzamiento para HPE Aruba Networking Instant Operating System versión 8.12.0.3, detallando nuevas características, plataformas compatibles, problemas resueltos y procedimientos de actualización.
Preview Notas de la versión 8.12.0.4 de HPE Aruba Networking Instant OS
Este documento proporciona notas de lanzamiento para HPE Aruba Networking Instant Operating System versión 8.12.0.4, detallando nuevas características, mejoras, problemas resueltos y problemas conocidos para varios modelos de puntos de acceso Aruba.
Preview Notas de la versión Aruba Instant 8.10.0.0
Notas de la versión de Aruba Instant 8.10.0.0, que detallan nuevas características, mejoras, problemas resueltos, problemas conocidos y procedimientos de actualización para los puntos de acceso Aruba.
Preview Manual de instrucciones de Aquaread BlackBox Mk2: Guía de configuración y funcionamiento del convertidor de datos de calidad del agua
Este completo manual de instrucciones de Aquaread Ltd. detalla la configuración, el funcionamiento y el mantenimiento del convertidor de datos de calidad del agua multiparamétrico BlackBox Mk2. Incluye información sobre el cableado, los protocolos de comunicación SDI-12 y Modbus, y la compatibilidad con diversas sondas Aquaprobe de Aquaread para aplicaciones de monitorización ambiental.