Sinotimer CN101S

Manual de instrucciones del temporizador digital LCD SINOTIMER CN101S

Modelo: CN101S

1. Introducción

The SINOTIMER CN101S is a reliable 1-second interval digital LCD timer switch designed for automatic control of various electrical equipment. This programmable time relay allows you to set precise ON/OFF schedules over a 7-day weekly cycle, with a minimum interval of 1 second. It is ideal for applications such as controlling streetlights, neon signs, lamps, calentadores de agua, aires acondicionados, vallas publicitarias, cocinas eléctricas, amplificadores, pulverizadores, embotelladores, precalentadores, instalaciones agrícolas y equipos de transmisión.

Equipped with a built-in battery, the CN101S retains its programmed settings even during power failures, ensuring continuous operation. Its design features low power consumption, a high-accuracy CMOS chip, and strong anti-jamming capabilities, making it simple and easy to set up and use.

2. Características principales

  • Control programable: 24 hours / 7 days a week programming with 1-second interval.
  • Alta capacidad: Rated for 3500 Watts / 16 Amps.
  • Respaldo de memoria: 1.2V built-in battery saves programs during power outages.
  • Exactitud: Auto time error correction of +/- 30 seconds weekly.
  • Vol de entrada / salidatage: 200-250 VCA, 50/60 Hz.
  • Configuración de salida: 1 Normally Open (NO) contact.
  • Material: Durable ABS + electronic components.
  • Diseño compacto: Easy to integrate into various setups.

3. Especificaciones técnicas

ParámetroValor
ModeloCN101S
Vol de entradatage200-250 V CA, 50/60 Hz
Vol de salidatage200-250 V CA
Corriente de carga máxima16 Amps
Potencia de carga máxima3500 vatios
Programabilidad24 hours / 7 days weekly
Intervalo mínimo1 segundo
Corrección de errores de tiempo+/- 30 seconds weekly (Auto)
Respaldo de memoria1.2V Built-in Battery
MaterialABS + Componentes electrónicos
Dimensiones (L x An x Al)7.0 cm x 7.0 cm x 4.0 cm

4. Configuración y cableado

Aviso importante de seguridad: Installation should be performed by a qualified electrician or knowledgeable individual. Ensure power is disconnected before attempting any wiring.

4.1 Diagrama de cableado

Refer to the diagram below for proper wiring connections. The timer features 5 terminals on the back for input power and load connection.

Atrás view of SINOTIMER CN101S showing terminals 1 to 5 with labels: 1-LINE INPUT, 2-NEUT INPUT, 3-NEUT POWER OUTPUT, 4-LOAD POWER OUTPUT, 5-LOAD POWER OUTPUT.
Figura 1: Posterior view with wiring terminals and specifications.
  • Terminal 1 (LINE INPUT): Connect the Live (L) wire of your 200-250VAC, 50/60Hz power supply.
  • Terminal 2 (NEUT INPUT): Connect the Neutral (N) wire of your 200-250VAC, 50/60Hz power supply.
  • Terminal 3 (NEUT POWER OUTPUT): Connect the Neutral (N) wire of your electrical load to this terminal. This provides the neutral path for the load.
  • Terminal 4 (LOAD POWER OUTPUT): Connect the Live (L) wire of your electrical load to this terminal. This is the switched Live output (Normally Open contact) that the timer will control.
  • Terminal 5 (LOAD POWER OUTPUT): This terminal is also labeled "LOAD". Given the specification of "1NO" (one Normally Open contact), Terminal 4 is the primary switched output. Terminal 5 may be an alternative connection point for the switched load or for specific dual-load configurations not typically used with a single NO relay. For standard operation, use Terminal 4 for the switched live to your load.

Asegúrese de que todas las conexiones estén seguras y aisladas.

4.2 Initial Power-Up and Display Overview

Once wired, apply power. The LCD display will illuminate. If the display is blank or dim, allow the internal battery to charge for a few minutes. The built-in 1.2V battery ensures that your programmed settings are retained even if the main power is interrupted.

Frente view of SINOTIMER CN101S showing LCD display and control buttons: MANUAL, P, D+, H+, M+, R, and a clock icon button.
Figura 2: Panel frontal con pantalla LCD y botones de control.

El panel frontal incluye:

  • Pantalla LCD: Shows current time, day, ON/OFF status, and programming modes.
  • Botón MANUAL: For manual override of the timer's output.
  • Botón P (Programa): Enters and navigates programming mode.
  • Botón D+ (Día): Adjusts the day of the week or selects days in program mode.
  • Botón H+ (Hora): Ajusta la hora.
  • Botón M+ (minuto): Ajusta los minutos.
  • Botón del icono del reloj: Used in conjunction with D+, H+, M+ to set the current time.
  • Botón R (Reinicio): Resets the timer to factory defaults (clears all programs and current time).

5. Instrucciones de funcionamiento

5.1 Configuración de la hora y el día actuales

  1. Mantenga pulsado el Icono de reloj botón.
  2. Mientras sostiene el Icono de reloj botón, presione D+ para configurar el día actual de la semana.
  3. Mientras sostiene el Icono de reloj botón, presione H+ para configurar la hora actual.
  4. Mientras sostiene el Icono de reloj botón, presione M+ para configurar el minuto actual.
  5. Liberar el Icono de reloj Botón. La hora y el día actuales ya están configurados.

5.2 Programación de horarios de encendido y apagado

The CN101S allows for multiple ON/OFF programs. Follow these steps to set your desired schedules:

  1. Presione el P (Programa) button once to enter program setting mode. The display will show "1 ON".
  2. Prensa D+ to select the day(s) for this program. You can choose individual days, weekdays, weekends, or all 7 days.
  3. Prensa H+ para establecer la hora de encendido deseada.
  4. Prensa M+ para establecer el minuto de encendido deseado.
  5. Prensa P (Programa) Presione el botón de nuevo. La pantalla mostrará "1 OFF".
  6. Prensa D+ to select the day(s) for this OFF program (usually the same as the ON program).
  7. Prensa H+ para establecer la hora de apagado deseada.
  8. Prensa M+ para establecer el minuto de apagado deseado.
  9. Para configurar programas adicionales, presione P (Programa) again to cycle through "2 ON", "2 OFF", and so on. Repeat steps 2-8 for each program.
  10. Una vez configurados todos los programas, presione el botón Icono de reloj Botón para salir del modo de programación y volver a la visualización de la hora actual.

The timer supports 1-second intervals, meaning you can set very precise ON/OFF durations. If a program is not needed, simply skip setting its ON/OFF times, or ensure the ON and OFF times are identical to effectively disable it.

5.3 Anulación manual

El MANUAL button allows you to temporarily override the programmed schedule. Pressing this button will cycle through different modes:

  • EN: La salida está continuamente encendida, ignorando los programas.
  • COCHE: The timer operates according to the programmed schedules.
  • OFF: La salida está continuamente apagada, ignorando los programas.

Select "AUTO" for the timer to follow your programmed schedules.

5.4 Reinicio del temporizador

To clear all programs and reset the current time to factory defaults, press the small R (Restablecer) button using a pointed object (like a pen tip). After resetting, you will need to set the current time and reprogram all schedules.

6. Mantenimiento

  • Limpieza: Limpie el exterior del temporizador con un paño suave y seco. No utilice limpiadores abrasivos ni disolventes.
  • Batería: The CN101S has a built-in 1.2V battery for memory backup. This battery is not user-replaceable. If the timer consistently loses settings after power outages, the battery may need servicing by a professional.
  • Ambiente: Ensure the timer is installed in a dry environment, away from direct sunlight, extreme temperatures, and corrosive substances.

7. Solución de problemas

ProblemaPosible causaSolución
La pantalla está en blanco o tenue.No power supply or internal battery discharged.Check power connections. Allow timer to charge for a few minutes after initial power-up.
El temporizador no se enciende ni se apaga según lo programado.Incorrect program settings, manual override active, or incorrect current time.
  • Verify current time and day are set correctly.
  • Check program settings (ON/OFF times, days).
  • Ensure the timer is in "AUTO" mode using the MANUAL button.
  • Verifique que las conexiones del cableado sean correctas y seguras.
Los programas se pierden después de un corte de energíatage.Internal backup battery is depleted or faulty.The battery is not user-replaceable. If this issue persists, consider professional servicing or replacement.
Los botones no responden.Fallo temporal del software o daño físico.Try pressing the R (Reset) button. If unresponsive, disconnect power for a few minutes and reconnect. If problem persists, contact support.

8. Consejos para el usuario

  • For critical applications, always double-check your programmed schedules after setting them.
  • Consider using the manual override function for temporary changes without altering your main programs.
  • When setting programs, ensure the ON time is before the OFF time within a 24-hour cycle, or that the OFF time is on the subsequent day if the cycle spans midnight.

9. Garantía y soporte

For technical assistance, warranty information, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documentos relacionados - CN101S

Preview Temporizador digital LCD HD serie SINOTIMER TM928: manual del usuario y especificaciones
Guía completa de los interruptores temporizadores digitales de la serie SINOTIMER TM928, que cubre características, especificaciones, configuración y cableado para modelos como TM919, TM920, TM928, TM928S, TM928R y TM929.
Preview Temporizador digital SINOTIMER TM-630A/TM-630S: Características y especificaciones
Especificaciones técnicas detalladas y características de los temporizadores programables digitales SINOTIMER TM-630A y TM-630S, incluida fuente de alimentación, rango de temporización, dimensiones y cableado.
Preview Temporizador programable semanal Sinotimer TM-616: Especificaciones y funcionamiento
Información detallada sobre el temporizador programable semanal Sinotimer TM-616, incluyendo especificaciones, funciones de los botones, dimensiones, diagramas de cableado y gama de productos. Cuenta con programación de 7 días y capacidad de conmutación de 30 A.
Preview Interruptor horario digital SINOTIMER TM-610 para riel DIN - Manual de usuario y especificaciones
Especificaciones detalladas, diagramas de cableado e instrucciones de funcionamiento del interruptor horario digital SINOTIMER TM-610, diseñado para montaje en riel DIN.
Preview Temporizador digital programable SINOTIMER TM618s - Manual de usuario y especificaciones
Guía completa del temporizador digital programable SINOTIMER TM618s, que abarca características, especificaciones, programación, cableado e instalación. Ideal para controlar dispositivos eléctricos con programaciones diarias de encendido y apagado.
Preview Manual del usuario del temporizador programable 3 en 1 de la serie SINOTIMER TM920
Manual de usuario completo del temporizador programable 3 en 1 SINOTIMER Serie TM920, con programación de 7 días, pulsos y cuenta regresiva. Aprenda a configurar la fecha, la hora, los modos de control y los días festivos.