1. Introducción

This manual provides essential information for the safe and effective use of your Enersys (Hawker) Cyclon 0809-0012 X-Cell 6 Volt/5 Amp Hour Sealed Lead Acid Battery. This 6-volt, 5 Ah pure lead sealed lead-acid battery is designed for general applications such as emergency lighting, UPS systems, and various electronic equipment. Please read this manual thoroughly before installation and operation.

Enersys Cyclon 0809-0012 X-Cell 6V 5Ah Sealed Lead Acid Battery

Figure 1: Enersys Cyclon 0809-0012 X-Cell 6V 5Ah Sealed Lead Acid Battery, front view.

2. Características del producto

The Enersys Cyclon 0809-0012 battery offers several key advantages:

3. Configuración e instalación

Follow these guidelines for proper setup and installation:

  1. Inspección: Before installation, visually inspect the battery for any signs of damage.
  2. Orientación: The battery can be installed in any orientation except inverted (terminals facing downwards).
  3. Conexiones: Ensure all connections are clean, tight, and correctly polarized. Connect the positive (+) terminal of the battery to the positive terminal of the load/charger, and the negative (-) terminal to the negative terminal. Incorrect polarity can damage the battery and connected equipment.
  4. Ventilación: While minimal gassing occurs, ensure adequate ventilation in the installation area.
  5. Condiciones ambientales: Install the battery in a cool, dry place, away from direct sunlight, heat sources, and flammable materials.
Close-up of battery positive terminal

Figura 2: Primer plano view of a battery terminal, showing the connection point.

Close-up of battery negative terminal

Figura 3: Otro primer plano view of a battery terminal, illustrating the robust design.

4. Operación

This sealed lead-acid battery is designed for reliable power delivery. For optimal performance and longevity, adhere to the following operational guidelines:

5. Mantenimiento

The Enersys Cyclon battery is a low-maintenance unit. However, proper care ensures maximum service life:

Battery recycling symbol and nonspillable label

Figure 4: Label indicating the battery is nonspillable and must be recycled.

6. Solución de problemas

Si tiene problemas con su batería, considere los siguientes pasos comunes de solución de problemas:

For persistent issues, consult a qualified technician or contact Enersys customer support.

7. Especificaciones

Key technical specifications for the Enersys Cyclon 0809-0012 battery:

EspecificaciónValor
Número de modelo0809-0012
MarcaEnergía
Volumentage6.00 voltios
Capacidad de la batería5 Amp Horas
Composición de las celdas de la bateríaBatería de plomo-ácido sellada
Dimensiones del producto5.48 x 2.12 x 3.02 pulgadas
Peso del artículo2.16 libras
Código Postal740737205131
ASINB0002ILK7W
Arriba view of Enersys Cyclon battery with label showing model number and specifications

Figura 5: Arriba view of the battery, displaying the product label with model number and key specifications.

8. Información de seguridad

Tenga en cuenta las siguientes precauciones de seguridad:

9. Garantía y soporte

For specific warranty details and customer support, please refer to the documentation provided at the time of purchase or contact Enersys directly through their official website or customer service channels. Ensure you have your model number (0809-0012) and purchase information available when seeking support.

Documentos relacionados - 0809-0012

Preview Especificaciones técnicas de la batería militar EnerSys ArmaSafe Plus 12FV120
Ficha técnica de la batería de grado militar EnerSys ArmaSafe Plus 12FV120, con capacidad de 126 Ah, 1225 A CCA y un amplio rango de temperatura de funcionamiento. Incluye especificaciones, características, beneficios e información de cumplimiento.
Preview Batería HAWKER Perfect Plus: Uživatelská Příručka pro Trakční Baterie PzS/PzB
Komplexní uživatelská příručka pro trakční baterie HAWKER Perfect Plus™ tipo PzS/PzB. Obsahuje informace o bezpečnosti, provozu, nabíjení, údržbě, skladování a volitelném příslušenství pro průmyslová vozidla.
Preview Ironclad Flooded Lead-Acid Batteries Owner's Manual
Comprehensive owner's manual for EnerSys Ironclad Flooded Lead-Acid Batteries, covering safe handling, installation, operation, maintenance, and troubleshooting.
Preview Manual del usuario de baterías EnerSys Perfect Plus y Water Less con certificación ATEX UKEX
This user manual provides comprehensive information on the safe handling, operation, maintenance, and installation of EnerSys Perfect Plus and Water Less ATEX UKEX certified batteries. It covers technical specifications, safety precautions, charging, discharging, and optional accessories like the Aquamatic water filling system and electrolyte circulation system.
Preview Manual de instalación, operación y mantenimiento de PowerSafe® SBS® EON®
Guía completa para la instalación, operación y mantenimiento de las baterías EnerSys PowerSafe SBS EON, con tecnología TPPL para un mejor rendimiento y longevidad.
Preview Cargador de batería modular Hawker Lifetech® - Instrucciones de uso
Instrucciones completas para el uso de los cargadores de baterías modulares Hawker Lifetech®, que abarcan seguridad, uso recomendado, conexiones eléctricas, funcionamiento y códigos de falla. Diseñados para baterías industriales de plomo-ácido, AGM y gel.