OMRON Healthcare HEM-1000

OMRON Digital Automatic Blood Pressure Monitor HEM-1000 User Manual

Modelo: HEM-1000

1. Producto terminadoview

The OMRON HEM-1000 is an automatic digital blood pressure monitor designed for easy and accurate blood pressure measurement. Its arm-in design simplifies the process, making it suitable for regular health monitoring at home.

This device non-invasively measures systolic and diastolic blood pressure for health management purposes. It is classified as a Specified Controlled Medical Device with certification number 218AGBZX00030A01.

OMRON HEM-1000 Digital Automatic Blood Pressure Monitor with arm inserted

Image: The OMRON HEM-1000 blood pressure monitor with a user's arm correctly inserted into the cuff for measurement.

2. Información de seguridad y precauciones

Please read this section carefully before using the blood pressure monitor to ensure proper and safe operation.

2.1. Contraindicaciones y prohibiciones

2.2. General Precautions for Use

  1. Individuals with severe blood disorders or blood diseases should use this device only under the guidance of a physician.
  2. If any abnormality occurs during measurement, immediately remove your arm from the cuff.
  3. Do not use this device on infants or individuals who cannot express themselves.
  4. Do not apply pressure above 300 mmHg.
  5. Do not use this device for any purpose other than blood pressure measurement.
  6. Avoid using mobile phones or smartphones near the blood pressure monitor during operation.
  7. Do not disassemble or modify the main unit.
  8. Asegúrese de que las baterías estén insertadas con la polaridad correcta (+/-).
  9. Utilice únicamente el tipo de pilas especificado.
  10. Retire las baterías si el dispositivo no se utilizará durante un período prolongado.

3. Instrucciones de configuración

3.1 Desembalaje e inspección inicial

Carefully remove the blood pressure monitor and all accessories from the packaging. Check for any visible damage. The package should include the main unit, AC adapter, 4 AA alkaline batteries (for trial use), and this instruction manual (with quality guarantee).

3.2. Instalación de la fuente de alimentación

The HEM-1000 can be powered by either the included AC adapter or batteries.

3.3. Colocación del dispositivo

Place the blood pressure monitor on a stable, flat surface such as a table. Ensure there is enough space for your arm to be comfortably inserted and rested.

4. Instrucciones de funcionamiento

Siga estos pasos para una medición precisa de la presión arterial:

4.1. Preparación para la medición

4.2. Procedimiento de medición

  1. Step 1: Insert Your Arm. Open the movable arm cuff and gently slide your arm into the cuff until it is comfortably positioned. The cuff is designed to guide your arm into the correct position automatically.
    Step 1: User inserting arm into the blood pressure monitor cuff.

    Image: Step 1 - Insert your arm into the cuff.

  2. Step 2: Ensure Correct Posture. The movable arm cuff helps you achieve the correct measurement posture. Your arm should be relaxed, and the cuff should be at heart level. Avoid leaning forward or having your arm at an incorrect angle.
    Step 2: Diagram showing correct and incorrect arm posture for blood pressure measurement.

    Image: Step 2 - Correct posture for measurement (arm at heart level, relaxed).

  3. Step 3: Start Measurement. Press the 'Measurement/Stop' button. The cuff will automatically inflate to the optimal pressure for your arm. Remain still and silent during the measurement.
    Step 3: Finger pressing the 'Measurement/Stop' button on the blood pressure monitor.

    Image: Step 3 - Press the 'Measurement/Stop' button to begin.

  4. View Resultados. Once the measurement is complete, your systolic blood pressure, diastolic blood pressure, and pulse rate will be displayed on the large LCD screen. The device also features an 'Irregular Heartbeat' detection function and a 'Body Movement' indicator.
    Display screen of the OMRON HEM-1000 showing blood pressure readings, user icon, time, body movement, and irregular pulse wave indicators.

    Image: The display shows systolic and diastolic pressure, user, time, and indicators for body movement and irregular pulse wave.

  5. Función de memoria. The device stores up to 90 readings for two users, allowing for long-term tracking of blood pressure trends.
    Diagram indicating memory capacity for 2 users, 90 readings each.

    Image: The device stores 90 readings for each of two users.

5. Mantenimiento

Proper maintenance ensures the longevity and accuracy of your blood pressure monitor.

5.1. Limpieza de la unidad

5.2. Almacenamiento

6. Solución de problemas

This section provides solutions to common issues you might encounter with your OMRON HEM-1000 blood pressure monitor.

ProblemaPosible causaSolución
El dispositivo no se enciende.Batteries are depleted or inserted incorrectly. AC adapter is not properly connected.Replace batteries with new ones, ensuring correct polarity. Check AC adapter connection to both the device and the power outlet.
Measurement results are inconsistent or appear inaccurate.Incorrect arm position or posture. Movement or talking during measurement. Cuff not properly applied.Ensure arm is correctly inserted and at heart level. Remain still and silent during measurement. Ensure the cuff is snug but not too tight. Rest for 5 minutes before re-measuring.
El manguito no se infla o se infla muy poco/mucho.Air tube blockage or leak. Cuff not properly connected. Device malfunction.Check for any kinks or damage in the air tube. Ensure the cuff is securely connected to the main unit. If the problem persists, contact customer service.
Se muestra un mensaje de error.Specific error condition (e.g., excessive movement, irregular pulse, cuff pressure error).Refer to the specific error code in the full instruction manual for detailed troubleshooting. Generally, re-measure after resting and ensuring correct procedure.

If you encounter issues not listed here or if problems persist after attempting these solutions, please contact OMRON Customer Service.

7. Especificaciones del producto

CaracterísticaEspecificación
Número de modeloHEM-1000
Dimensiones externas (An x Al x Pr)230 x 217 x 228 mm
PesoAprox. 1600 g (sin pilas)
Applicable Arm CircumferenceDe 170 mm a 320 mm
Fuente de poderAC Adapter or 4 x AA Alkaline Batteries
Tipo de pantallaLCD digital
Condiciones del entorno operativo+10 to +40°C, 15 to 85% RH (non-condensing), 800 to 1060 hPa
Clasificación de dispositivos médicosSpecified Controlled Medical Device
Medical Device Certification Number218AGBZX00030A01
Diagram showing the dimensions of the OMRON HEM-1000 blood pressure monitor.

Image: Device dimensions (Width: approx. 230mm, Height: approx. 217mm, Depth: approx. 228mm).

8. Garantía y soporte

8.1. Garantía del fabricante

OMRON Healthcare provides a warranty for this product under the following conditions:

8.2. Atención al cliente

For any inquiries, support, or service requests, please contact:

OMRON Healthcare Co., Ltd.
Centro de atención al cliente
Teléfono: 0120-30-6606

Documentos relacionados - HEM-1000

Preview 自動体外式除細動器 レスキューハート HDF-3500 知らせ
オムロン ヘルスケア株式会社は、自動体外式除細動器(AED)「レスキューハートHDF-3500」の一部製品について、回路基板の故障により電気ショックができない可能性があるため、自主回収を実施しています。対象製品のシリアル番号や回収方法について詳細をご確認ください.
Preview Omron Healthcare Service Overview: Repair and Support Information
Official service overview and repair instructions for Omron Healthcare products in the United States and Canada. Details mission, quality standards (ISO 13485), and procedures for returning units for repair, including required contact information and documentation.
Preview Certificado de aprobación del monitor de presión arterial Omron Healthcare HEM-7600T-E
Certificado de Aprobación Oficial de Tipo de Equipo (ETA) otorgado por el Gobierno de la India, Departamento de Telecomunicaciones para el monitor de presión arterial Omron Healthcare HEM-7600T-E, que detalla las especificaciones técnicas y las condiciones de uso.
Preview EMC Test Report for OMRON HEALTHCARE BLOOD PRESSURE MONITOR HEM-7140T1
This Electromagnetic Compatibility (EMC) test report details the compliance testing for the OMRON HEALTHCARE BLOOD PRESSURE MONITOR, Model HEM-7140T1, against EN 301 489-1 and EN 301 489-17 standards. The report confirms the device's compliance with EMC requirements.
Preview OMRON Intellisense AFib: Early Detection of Atrial Fibrillation Risk via Blood Pressure Measurement
OMRON Healthcare's Intellisense AFib technology revolutionizes cardiovascular health by enabling atrial fibrillation risk detection during routine blood pressure monitoring. Learn how this innovative AI-powered system enhances early diagnosis and prevention of serious conditions like stroke.
Preview オムロンヘルスケア株式会社 2024年度 医療機関等への資金提供に関する情報
オムロンヘルスケア株式会社が2024年度に医療機関等へ提供した資金の詳細。研究費、助成金、謝金、情報提供費用、その他の費用が含まれます。