The First Alert BRK SC-9120B is a hardwired smoke and carbon monoxide (CO) detector designed to provide continuous 24/7 protection for your home. This dual-sensor alarm combines an ionization smoke sensor for detecting fast-flaming fires and an electrochemical carbon monoxide sensor for accurate CO detection. It features a 120V AC power source with a 9V alkaline battery backup, ensuring operation even during power outages.

First Alert BRK SC-9120B Combination Smoke and CO Detector

Figura 1.1: Frente view of the First Alert BRK SC-9120B Combination Smoke and CO Detector.

Key features include a single test/silence button, separate latching alarm indicators for smoke and CO, and a silencing technology that can temporarily quiet low-battery chirps for up to eight hours or nuisance alarms. The unit also provides an audible end-of-life signal, indicating when it's time for replacement.

First Alert BRK SC-9120B installed on a ceiling

Figure 1.2: The First Alert BRK SC-9120B detector installed on a ceiling, blending with home decor.

2. Información importante de seguridad

Please read and understand all instructions before installing and operating your detector. Failure to follow these instructions may result in property damage, injury, or death.

  • Esta unidad está diseñada para uso en interiores únicamente.
  • Ensure the detector is connected to a 120V AC power supply.
  • A 9V alkaline battery is required for backup power and must be installed for proper operation. The battery is not included with the unit.
  • Regularly test your detector as described in the Operating Instructions section.
  • Do not paint the detector. Paint can clog the sensing chambers and prevent the alarm from operating properly.
  • The detector has an end-of-life signal. When this signal sounds, the unit must be replaced immediately.

3. Contenido del paquete

Verifique que todos los artículos estén presentes en su paquete:

  • First Alert SC-9120B Combination Smoke and CO Detector Unit
  • Soporte de montaje
  • Quick Connect Wiring Harness
  • Herrajes de instalación (tornillos, anclajes de pared)
  • Manual de usuario

Nota: A 9V alkaline battery is required for battery backup functionality and is not included in the package. Please purchase separately.

4. Configuración e instalación

The First Alert BRK SC-9120B is designed for easy installation, featuring a universal mount bracket and keyhole slots that simplify the process.

4.1 Elegir una ubicación

For optimal protection, install smoke alarms on every level of your home, inside bedrooms, and outside sleeping areas. Carbon monoxide alarms should be installed on every level of your home and in sleeping areas. Avoid installing near vents, fans, or in extremely dusty, dirty, or humid areas.

4.2 Instrucciones de cableado

This detector is hardwired and connects to your home's 120V AC electrical system. A large opening in the mounting bracket provides easy access to wiring. Use the quick connect wiring harness for secure connections.

Atrás view of First Alert BRK SC-9120B showing wiring connections

Figura 4.1: Posterior view of the detector illustrating the wiring harness connection points (Black, Orange, White).

Conexiones de cableado:

  • Cable negro: Connect to the hot (live) wire from the electrical box.
  • Alambre blanco: Connect to the neutral wire from the electrical box.
  • Cable naranja: (Interconnect) Connect to the interconnect wire from other compatible First Alert/BRK alarms for synchronized alarming.

Ensure all power to the circuit is turned off at the main fuse or circuit breaker box before beginning installation.

4.3 Instalación de la batería

A 9V alkaline battery is required for backup power. The battery compartment is located on the side of the unit, allowing for installation and removal even when the unit is mounted.

First Alert BRK SC-9120B with battery compartment open

Figura 4.2: Lado view of the detector with the 9V battery compartment open.

Insert the 9V battery, ensuring correct polarity (+/-). A battery pull tab keeps the battery fresh until the unit is installed and activated. Once the battery is installed and the unit is connected to AC power, the detector is ready for operation.

5. Instrucciones de funcionamiento

Your First Alert BRK SC-9120B detector is designed for simple operation and clear indication of alarm conditions.

5.1 Botón de prueba/silencio

The large test/silence button on the front of the unit serves two primary functions:

  • Pruebas: Press and hold the button to test the alarm's functionality. The alarm will sound, indicating that the smoke and CO sensors are working. Test the alarm weekly.
  • Silenciamiento: In case of a nuisance alarm (e.g., from cooking smoke), press the button to temporarily silence the alarm. The alarm will reset after a few minutes if the smoke or CO levels return to normal.
  • Low Battery Chirp Silence: If the unit chirps due to a low battery, pressing the button can silence the chirp for up to eight hours, allowing time to replace the battery.

5.2 Indicadores de alarma

The detector features separate latching alarm indicators for smoke and carbon monoxide. These indicators will illuminate and remain on to show which unit initiated an alarm, even after the alarm has stopped sounding. This helps in identifying the source of the alert.

6. Mantenimiento

Regular maintenance ensures the continued reliable operation of your detector.

6.1 Reemplazo de batería

Replace the 9V alkaline battery at least once a year, or immediately when the low battery chirp sounds (unless silenced temporarily). Use only recommended replacement batteries.

6.2 Limpieza del detector

Dust and debris can accumulate on the detector, potentially affecting its performance. Clean your detector at least once a month:

  • Gently vacuum the exterior of the alarm using the soft brush attachment of your vacuum cleaner.
  • Do not use cleaning solvents or sprays directly on the unit.

6.3 Señal de fin de vida útil

The detector is designed with an end-of-life signal that provides an audible notification when the unit needs to be replaced. This typically occurs after 10 years of operation. When you hear this signal, replace the detector immediately.

7. Solución de problemas

If your detector is not functioning as expected, refer to the following common issues and solutions:

ProblemaPosible causaSolución
Alarm sounds frequently without apparent reason.Nuisance alarm (cooking smoke, steam), dust accumulation, improper placement.Press the Test/Silence button. Clean the detector. Relocate if consistently triggered by non-emergency events.
Unit chirps periodically.Batería baja.Replace the 9V battery. You can silence the chirp for up to 8 hours by pressing the Test/Silence button.
La alarma no suena durante la prueba.No power (AC or battery), faulty unit.Check AC power connection. Ensure 9V battery is installed correctly. If issues persist, replace the unit.
End-of-life signal sounds.Detector has reached its operational lifespan.Replace the entire detector unit immediately.
Only one interconnected alarm sounds.Interconnect wiring issue, or the initiating unit's latching alarm indicator is the only one active.Check interconnect wiring. Identify the initiating unit by its latching alarm indicator.

8. Especificaciones

CaracterísticaDetalle
MarcaPrimera alerta
Número de modeloSC9120B
Fuente de poderHardwired (120V AC) with 9V Battery Backup
Tipo de bateríaAlcalina de 9 V (no incluida)
Tipo de sensorIonización (humo), electroquímica (CO)
Tipo de alarmaAudible
Dimensiones del producto2.25" de profundidad x 5.59" de ancho x 5.69" de alto
Peso del artículo10.4 onzas
MaterialPlástico
UsoUso en interiores únicamente
FabricanteBRK Brands

9. Garantía y soporte

The First Alert BRK SC-9120B Combination Smoke and Carbon Monoxide Detector comes with a Garantía limitada de 10 añosEsta garantía cubre defectos de material y mano de obra en condiciones normales de uso y servicio.

For warranty claims, technical support, or further assistance, please refer to the contact information provided in the documentation included with your product or visit the official First Alert websitio.

Documentos relacionados - SC9120B

Preview Guía del propietario de First Alert: Cómo entender las alarmas de humo y las alarmas combinadas de humo y CO
A comprehensive guide from First Alert and BRK Electronics for homeowners, explaining the features, operation, maintenance, and importance of smoke and smoke/CO combo alarms. Covers LED indicators, battery backup, interconnected systems, and carbon monoxide safety.
Preview First Alert BRK Smoke and Smoke/CO Detectors: User Manuals & Installation Guides
Comprehensive user manuals and installation guides for First Alert BRK 3120B-6 Smoke Detector and SC7010BV Smoke & Carbon Monoxide Detector. Learn about features, installation, safety, and troubleshooting for these essential home safety devices.
Preview Manual del usuario de la alarma de humo y monóxido de carbono First Alert Onelink Wi-Fi AC10-500
Manual de usuario completo para la alarma de humo y monóxido de carbono First Alert Onelink AC10-500 Wi-Fi, que abarca la instalación, el funcionamiento, el mantenimiento, la solución de problemas y la información de seguridad. Aprenda sobre las funciones de la alarma, su ubicación, la configuración y los procedimientos de emergencia.
Preview Alarmas First Alert ONELINK: Preguntas frecuentes y guía
Descubra las características, la instalación y las ventajas de los detectores de humo y monóxido de carbono First Alert ONELINK, interconectables de forma inalámbrica. Esta guía responde a las preguntas más frecuentes de propietarios y contratistas.
Preview Manual del usuario de la alarma combinada de humo y monóxido de carbono First Alert 7030BSL con luz estroboscópica LED
Manual de usuario completo para la alarma combinada de humo y monóxido de carbono First Alert 7030BSL con luz estroboscópica LED integrada. Abarca la instalación, el funcionamiento, el mantenimiento, consejos de seguridad y la resolución de problemas.
Preview Manual del usuario de la alarma combinada de humo y monóxido de carbono First Alert ZCOMBO
Manual de usuario completo de la alarma combinada de humo y monóxido de carbono First Alert ZCOMBO. Aprenda sobre la instalación, el mantenimiento, las pruebas, las funciones de seguridad, la resolución de problemas y la integración con Z-Wave para una mayor seguridad en el hogar.