Sealey MM19

Sealey MM19 Digital Multimeter 7 Function User Manual

1. Introducción

This manual provides instructions for the safe and effective use of the Sealey MM19 Digital Multimeter. The MM19 is a general-purpose multimeter designed for measuring various electrical parameters, including AC and DC voltage, DC current, resistance, audible continuity, and diode/transistor verification. Please read this manual thoroughly before operation and retain it for future reference.

2. Información de seguridad

Always observe basic safety precautions when using electrical test equipment to reduce the risk of fire, electric shock, or personal injury. This device complies with IEC 1010 and CE CAT II safety standards.

  • No exceda los límites máximos de entrada for any function. Refer to the specifications section for details.
  • Nunca aplique voltage to the meter when the rotary switch is set to Resistance (Ω), Diode, Continuity, or Current (A) functions.
  • Tenga cuidado al trabajar con vol.tages superior a 30 V CA RMS, 42 V pico o 60 V CC. estos voltagPueden suponer un riesgo de descarga eléctrica.
  • Ensure the test leads are in good condition, without cracked or broken insulation.
  • Always connect the common (COM) test lead first and disconnect it last.
  • Disconnect power to the circuit under test before measuring resistance or continuity.
  • Reemplace la batería inmediatamente cuando aparece el indicador de batería baja para garantizar lecturas precisas.

3. Producto terminadoview

The Sealey MM19 Digital Multimeter features a clear LCD display, a central rotary switch for function selection, and input jacks for test leads.

Sealey MM19 Digital Multimeter with test leads

The Sealey MM19 Digital Multimeter, shown with its yellow casing, large LCD display, rotary function switch, and red and black test leads connected to the input jacks.

Componentes:

  • Pantalla LCD: Large (46 x 25mm) digital display for reading measurements.
  • Interruptor giratorio: Se utiliza para seleccionar la función y el rango de medición deseados.
  • Conector de entrada VΩmA: Por voltagMediciones de e, resistencia y corriente hasta 200 mA.
  • 10ADC Input Jack: For high current measurements up to 10A DC (unfused).
  • Conector de entrada COM: Entrada común (negativa) para todas las mediciones.
  • Zócalo hFE: For transistor (NPN/PNP) testing.
  • Cables de prueba: Cables rojo (positivo) y negro (negativo) para conectar a circuitos.

4. Configuración

4.1. Instalación de la batería

The Sealey MM19 Multimeter requires a 9V battery for operation. If the display does not illuminate or shows a low battery indicator, the battery needs to be installed or replaced.

  1. Asegúrese de que el multímetro esté apagado.
  2. Localice la tapa del compartimiento de la batería en la parte posterior de la unidad.
  3. Retire el/los tornillo(s) que sujetan la cubierta y levántela con cuidado.
  4. Conecte una batería nueva de 9 V a los clips de la batería, observando la polaridad correcta.
  5. Coloque la batería dentro del compartimiento y vuelva a colocar la tapa, asegurándola con el/los tornillo(s).

4.2. Conexión de los cables de prueba

The multimeter is supplied with a pair of test leads (red and black).

  • Insertar el cable de prueba negro dentro del COM Toma de entrada (común).
  • Para la mayoría de las mediciones (voltage, resistance, low current), insert the cable de prueba rojo dentro del VΩmA toma de entrada.
  • For high DC current measurements (up to 10A), insert the cable de prueba rojo dentro del 10ADC toma de entrada.

5. Instrucciones de funcionamiento

To operate the multimeter, select the desired function and range using the rotary switch.

5.1. Medición del volumen de CCtagmi (DCV)

  1. Insert the red lead into the VΩmA jack and the black lead into the COM jack.
  2. Set the rotary switch to the desired DCV range (e.g., 200m, 2000m, 20, 200, 1000). Start with the highest range if the voltage es desconocido.
  3. Conecte los cables de prueba al componente o circuito que se va a medir.
  4. Leer el vol.tage valor en la pantalla LCD.

5.2. Medición del volumen de CAtage (ACV)

  1. Insert the red lead into the VΩmA jack and the black lead into the COM jack.
  2. Set the rotary switch to the desired ACV range (e.g., 200, 750). Start with the highest range if the voltage es desconocido.
  3. Conecte los cables de prueba al componente o circuito que se va a medir.
  4. Leer el vol.tage valor en la pantalla LCD.

5.3. Medición de corriente continua (DCA)

  1. Para corrientes de hasta 200 mA: Insert the red lead into the VΩmA jack and the black lead into the COM jack.
  2. Para corrientes de hasta 10A: Insert the red lead into the 10ADC jack and the black lead into the COM jack.
  3. Set the rotary switch to the desired DCA range (e.g., 200μ, 2000μ, 20m, 200m, 10A). Start with the highest range if the current is unknown.
  4. Apague la alimentación al circuito. Abra el circuito donde se va a medir la corriente.
  5. Conecte el multímetro en serie con el circuito.
  6. Aplique energía al circuito y lea el valor actual en la pantalla LCD.

5.4. Medición de la resistencia (Ω)

  1. Insert the red lead into the VΩmA jack and the black lead into the COM jack.
  2. Set the rotary switch to the desired Resistance (Ω) range (e.g., 200, 2000, 20k, 200k, 2000k).
  3. Asegúrese de que el circuito bajo prueba esté desenergizado.
  4. Conecte los cables de prueba al componente que se va a medir.
  5. Lea el valor de resistencia en la pantalla LCD.

5.5. Prueba de continuidad audible

  1. Insert the red lead into the VΩmA jack and the black lead into the COM jack.
  2. Coloque el interruptor giratorio en el símbolo de continuidad (icono de altavoz).
  3. Asegúrese de que el circuito bajo prueba esté desenergizado.
  4. Conecte los cables de prueba a través del componente o cable.
  5. If continuity exists (low resistance), the meter will emit an audible tone. The display will show the resistance value.

5.6. Diode/Transistor Verification Mode (hFE)

  1. Insert the red lead into the VΩmA jack and the black lead into the COM jack for diode testing.
  2. Set the rotary switch to the diode symbol.
  3. Conecte el cable rojo al ánodo y el cable negro al cátodo del diodo. La pantalla mostrará el voltaje directo.tage drop. Invierta los cables; la pantalla debería mostrar 'OL' (bucle abierto) para un diodo en buen estado.
  4. For transistor hFE measurement, insert the transistor leads (Emitter, Base, Collector) into the appropriate sockets (E, B, C) in the hFE test socket, ensuring correct NPN or PNP type selection.
  5. Lea el valor hFE en la pantalla LCD.

6. Mantenimiento

6.1. Limpieza

Limpie el medidor casing con anuncioamp Paño y detergente suave. No utilice abrasivos ni disolventes. Asegúrese de que el medidor esté completamente seco antes de usarlo.

6.2. Reemplazo de la batería

Refer to Section 4.1 for battery installation instructions. Replace the 9V battery when the low battery indicator appears on the display to maintain measurement accuracy.

7. Solución de problemas

  • Sin pantalla: Verifique la instalación de la batería y asegúrese de que tenga suficiente carga.
  • 'OL' o '1' en pantalla: This usually indicates an over-range condition or an open circuit. Select a higher range or check connections.
  • Lecturas incorrectas: Ensure the correct function and range are selected. Check test lead connections and battery condition.
  • Sin tono de continuidad: Verify the circuit is de-energized and the leads are making good contact.

8. Especificaciones

ParámetroValor
MarcaSealey
Número de modeloMM19
Fuente de poderFunciona con pilas (9 V)
MostrarDigital LCD (46 x 25mm)
Vol DCtagmi (DCV)200 mV, 2000 mV, 20 V, 200 V, 1000 V
Vol. CAtage (ACV)200 V, 750 V
Corriente CC (DCA)200 µA, 2000 µA, 20 mA, 200 mA, 10 A
Resistencia (Ω)200Ω, 2000Ω, 20kΩ, 200kΩ, 2000kΩ
ContinuidadAudible tone below approx. 30Ω
Prueba de diodoVol hacia adelantetage drop display
Prueba de transistorhFE (NPN/PNP)
Clasificación de seguridadCE CAT II, IEC 1010
Dimensiones (L x An x Al)1.93 x 4.21 x 6.06 pulgadas
Peso del artículo9.5 onzas (0.27 kilogramos)

9. Garantía y soporte

For warranty information or technical support, please refer to the documentation provided with your purchase or contact Sealey customer service directly. Keep your proof of purchase for any warranty claims.

Documentos relacionados - MM19

Preview Manual del usuario del multímetro digital de 7 funciones Sealey MM19.V3
Manual de usuario completo para el multímetro digital Sealey MM19.V3 de 7 funciones, que detalla instrucciones de seguridad, especificaciones, características y funcionamiento para voltaje CA/CC.tage, corriente continua, resistencia, continuidad y mediciones de transistores.
Preview Manual de usuario e instrucciones del multímetro digital de rango automático profesional Sealey MM102
Manual de usuario detallado e instrucciones de funcionamiento del multímetro digital de rango automático profesional Sealey MM102, incluidas precauciones de seguridad, especificaciones y guías de mantenimiento.
Preview Multímetro digital profesional de rango automático Sealey TM102 de 8 funciones - Manual del usuario
Manual de usuario completo del multímetro digital profesional de rango automático Sealey TM102 de 8 funciones. Incluye instrucciones de seguridad, especificaciones, guía de funcionamiento y procedimientos de mantenimiento.
Preview Manual del usuario del analizador digital automotriz Sealey TA101 de 12 funciones
Manual de usuario completo del analizador digital automotriz Sealey TA101 de 12 funciones. Detalla precauciones de seguridad, especificaciones técnicas, procedimientos de operación para diversas mediciones, mantenimiento y resolución de problemas.
Preview Manual del usuario de la sonda automática Sealey 6-24V Plus PPX.V4
Instrucciones completas para Sealey 6-24V Auto Probe Plus (modelo n.° PPX.V4), que cubren seguridad, características, funcionamiento, pruebas y resolución de problemas de sistemas eléctricos automotrices.
Preview Ficha de datos de seguridad del aceite hidráulico del gato hidráulico Sealey 1050CXLE v3
Ficha de datos de seguridad del gato hidráulico Sealey 1050CXLE v3 de 2 toneladas y bajo rendimientofile Aceite hidráulico de chasis corto, detallando identificación del producto, peligros, primeros auxilios, lucha contra incendios, manipulación, almacenamiento, propiedades físicas y eliminación.