1. Introducción
The ABB S203-C32 is a three-pole miniature circuit breaker (MCB) designed for reliable protection of electrical circuits against overloads and short circuits. This device is part of the S200 series, engineered for easy installation and robust performance in various applications, including residential and commercial buildings.
It features a C-characteristic activation, meaning it trips when the overcurrent is 5 to 10 times the nominal current, making it suitable for circuits with moderate inrush currents. With a nominal current of 32 Amperes and a rated breaking capacity of 6 kA according to EN 60898-1, the S203-C32 provides essential safety for three-phase electrical systems.

Figura 1: General view of the ABB S203-C32 Circuit Breaker.
2. Información de seguridad
ADVERTENCIA: Los trabajos eléctricos solo deben ser realizados por personal cualificado y autorizado. El incumplimiento de estas instrucciones puede provocar lesiones graves o la muerte.
- Desconecte siempre la alimentación principal antes de instalar, realizar mantenimiento o quitar el disyuntor.
- Verificar que el voltagAsegúrese de que los valores nominales de corriente y voltaje del disyuntor coincidan con los requisitos de su sistema eléctrico.
- Asegúrese de que la conexión a tierra y el cableado sean adecuados de acuerdo con los códigos y regulaciones eléctricas locales.
- No opere el disyuntor si parece dañado o ha sido sometido a una fuerza excesiva.
- Wear appropriate personal protective equipment (PPE), such as insulated gloves and safety glasses, when working with electrical systems.
3. Instalación
The ABB S203-C32 circuit breaker is designed for easy installation on standard DIN rails. Its patented twin terminals with spring-loaded screws facilitate secure connection of conductors.
3.1 Montaje en carril DIN
- Ensure the main power supply to the distribution board is switched off and locked out.
- Align the circuit breaker with the DIN rail.
- Press the circuit breaker firmly onto the DIN rail until it clicks into place. Ensure it is securely seated.

Figura 2: Lado view que ilustra el mecanismo de montaje en riel DIN.
3.2 conexiones de cableado
The S203-C32 features three poles for three-phase circuit protection. It is equipped with twin terminals that allow for secure wiring.
- Strip the insulation from the conductor ends to the recommended length (typically 12-14 mm).
- Insert the conductors into the appropriate terminals (input and output). The terminals are designed to accept conductors up to 35 mm² cross-section.
- Tighten the terminal screws to the specified torque (refer to product markings or technical data sheet for exact torque values, typically 2.8 Nm). Ensure connections are firm to prevent loose contacts and overheating.
- Verify all connections are secure and that no bare wires are exposed, ensuring touch protection according to IP20.

Figura 3: View of the wiring terminals for conductor connection.

Figura 4: detallada view of the patented twin terminals.
4. Operación
The ABB S203-C32 circuit breaker operates automatically to protect electrical circuits. It has two primary states: ON and OFF, and an automatic trip state.
- Posición ON: When the toggle switch is in the upward position, the circuit is closed, allowing current to flow.
- Posición OFF: When the toggle switch is in the downward position, the circuit is open, interrupting current flow. This position is used for manual disconnection.
- Posición disparada: In the event of an overload or short circuit, the circuit breaker will automatically trip, moving the toggle switch to an intermediate or fully down position (depending on the specific mechanism). This indicates a fault in the circuit.
To reset a tripped circuit breaker, first identify and rectify the cause of the trip (e.g., remove overloaded devices or fix short circuits). Then, firmly push the toggle switch all the way down to the OFF position, and then back up to the ON position.

Figura 5: Frente view displaying the toggle switch for operation.
5. Mantenimiento
The ABB S203-C32 circuit breaker is designed for maintenance-free operation under normal conditions. However, periodic inspection is recommended to ensure continued reliability and safety.
- Inspección visual: Regularly inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. Ensure the toggle switch moves freely.
- Limpieza: Si es necesario, limpie suavemente el exterior del disyuntor con un paño seco y sin pelusa. No utilice limpiadores abrasivos ni disolventes. Asegúrese de que la alimentación esté desconectada antes de limpiarlo.
- Verificación de conexión: Periodically check the tightness of the terminal screws, especially after initial installation and during routine electrical system checks.
If any damage or malfunction is observed, the circuit breaker should be replaced by a qualified electrician.
6. Solución de problemas
This section provides guidance for common issues encountered with circuit breakers.
6.1 El disyuntor se dispara con frecuencia
- Sobrecarga: The most common cause. Disconnect some appliances or devices from the circuit.
- Cortocircuito: A direct connection between live and neutral/ground wires. This requires immediate attention from a qualified electrician to identify and repair the fault.
- Electrodoméstico defectuoso: An appliance connected to the circuit may be faulty and drawing excessive current. Unplug all appliances and plug them back in one by one to identify the culprit.
- Conexiones sueltas: Loose wiring connections can cause arcing and heat, leading to tripping. Have a qualified electrician inspect and tighten all connections.
6.2 Circuit Breaker Will Not Reset
- Falla persistente: If the underlying overload or short circuit condition still exists, the breaker will immediately trip again when you try to reset it. Do not force it.
- Daño interno: The circuit breaker itself may be damaged internally. If no fault is found in the circuit and the breaker still won't reset, it likely needs replacement.
If you are unable to resolve the issue, contact a qualified electrician for assistance.
7. Especificaciones
Key technical specifications for the ABB S203-C32 Circuit Breaker:
| Característica | Valor |
|---|---|
| Marca | TEJIDO |
| Número de modelo | S203-C32 |
| ASIN | B000VG0Q4I |
| Número de polos | 3 |
| Calificación actual | 32 Ampantes de |
| Tipo de interruptor | Estándar |
| Tipo de montaje | Montaje en carril DIN |
| Dimensiones del producto | 6.9D x 5.3W x 8.8H cm (6.9 x 5.25 x 8.8 cm) |
| Peso | 100 gramos |
| Fabricante descontinuado | No |
| Primera fecha disponible | 15 de enero de 2020 |
| Disponibilidad de repuestos en la UE | 1 año |
| GTIN | 4016779468305 |

Figure 6: Product dimensions of the ABB S203-C32.
8. Garantía y soporte
For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your retailer. ABB products typically come with a manufacturer's warranty covering defects in materials and workmanship.
For technical support, product inquiries, or service, please contact ABB customer service or visit the official ABB website. Ensure you have your product model number (S203-C32) and any relevant purchase information ready when seeking support.