1. Introducción

The Intermatic PF1202T Control System is designed to manage pool and spa equipment operation, incorporating essential freeze protection. This system features two T104M mechanisms for precise scheduling and an adjustable thermostat to safeguard your equipment against freezing temperatures. It is suitable for installations requiring one or two time switches.

Key features of this control system include:

2. Información de seguridad

ADVERTENCIA: To avoid serious injury or death, always disconnect power at the circuit breaker or fuse box before installing or servicing this control system. Installation and servicing should be performed by a qualified electrician in accordance with all national and local electrical codes.

3. Configuración e instalación

3.1. Desembalaje

Carefully remove the control system from its packaging. Inspect the unit for any signs of damage during transit. Retain all packaging materials until you have confirmed the unit is in working order.

3.2. Montaje

Mount the control system vertically on a flat, rigid surface using appropriate fasteners. Ensure the mounting location allows for proper ventilation and access for wiring and maintenance. The enclosure is designed for outdoor use.

3.3. cableado

IMPORTANTE: All wiring must be performed by a qualified electrician and comply with local and national electrical codes. The unit operates at 240 Volts and has a current rating of 17 Amps. Use appropriate gauge wiring for the load. The terminal type is screw-type for secure connections.

Refer to the wiring diagram located inside the control system's door for specific connection details. Ensure all connections are tight and secure before restoring power.

Intermatic PF1202T Control System with open door, showing two time switches and a freeze protection thermostat.

Figura 1: Intermatic PF1202T Control System with the front door open. The image displays the internal components, including two yellow time switch mechanisms at the top, each with ON/OFF levers. Below these are two blank cover plates, and on the left side, a black dial for the freeze protection thermostat, labeled with temperature settings from 32°F to 44°F. The inside of the door shows a wiring diagram and product information label.

4. Instrucciones de funcionamiento

4.1. Setting the T104M Time Switches

The PF1202T includes two T104M time switches to control your pool or spa equipment. Each time switch allows for independent scheduling of ON/OFF cycles.

  1. Establecer hora actual: Pull out the dial and rotate it clockwise until the current time aligns with the arrow on the mechanism. Push the dial back in.
  2. Establecer horarios de encendido y apagado: Each time switch comes with ON (green) and OFF (red) trippers. To set an ON time, slide a green tripper onto the dial at the desired ON time. To set an OFF time, slide a red tripper onto the dial at the desired OFF time. Additional trippers can be purchased separately for more complex schedules.
  3. Anulación manual: The red lever below each dial allows for manual override. Moving the lever to "ON" or "OFF" will temporarily override the programmed schedule until the next tripper engages. Ensure the lever is in the "AUTO" position for automatic operation.

4.2. Adjusting the Freeze Protection Thermostat

The integrated freeze protection thermostat automatically activates your pump and/or heater when the ambient temperature drops to a critical level, preventing freeze damage to your plumbing and equipment.

5. Mantenimiento

The Intermatic PF1202T Control System requires minimal maintenance. Regular inspection can help ensure long-term reliable operation.

6. Solución de problemas

This section provides solutions to common issues you may encounter with your PF1202T Control System. For problems not listed here, or if solutions do not resolve the issue, contact a qualified electrician or Intermatic customer support.

ProblemaPosible causaSolución
Equipment does not turn ON/OFF at scheduled times.
  • Incorrect time set on dial.
  • Trippers not properly installed or missing.
  • Manual override lever is engaged.
  • No llega energía a la unidad.
  • Pull out dial and rotate to current time, then push back in.
  • Ensure green (ON) and red (OFF) trippers are securely placed at desired times.
  • Set manual override lever to "AUTO".
  • Verifique el disyuntor y la fuente de alimentación.
Freeze protection not activating.
  • Thermostat set point too low.
  • Thermostat sensor obstructed or faulty.
  • No llega energía a la unidad.
  • Adjust thermostat dial to a higher temperature.
  • Clear any obstructions from the sensor. If still not working, contact support.
  • Verifique el disyuntor y la fuente de alimentación.
La unidad no tiene energía.
  • Disyuntor disparado o fusible quemado.
  • Conexión de cableado suelta.
  • Verifique y reinicie el disyuntor o reemplace el fusible.
  • With power disconnected, inspect and tighten all wiring connections.

7. Especificaciones

Technical specifications for the Intermatic PF1202T Control System:

CaracterísticaDetalle
MarcaIntermático
ModeloPF1202T
Modo de operaciónENCENDIDO-APAGADO-ENCENDIDO
Calificación actual17 Amps
Vol de funcionamientotage240 voltios
Tipo de contactoNormalmente abierto
Tipo de conectorTornillo
TerminalTipo de tornillo
Dimensiones del artículo L x W x H6 x 12 x 14 pulgadas
Tipo de circuito1 vías
Tipo de actuadorBotón pulsador

8. Garantía y soporte

Intermatic products are manufactured to high-quality standards and are backed by a limited warranty. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official Intermatic websitio.

For technical assistance, troubleshooting, or to inquire about replacement parts, please contact Intermatic customer support. Contact information can typically be found on the manufacturer's websitio o en el embalaje del producto.

Documentos relacionados - PF1202T

Preview Manual del propietario del temporizador portátil para piscinas y spas Intermatic P1161: seguridad, configuración y prueba de GFCI
Manual completo del usuario del temporizador portátil de seguridad para piscinas y spas Intermatic P1161. Incluye instrucciones de seguridad importantes, cómo configurar el temporizador, información sobre la garantía, explicación del GFCI, guía de solución de problemas y procedimientos de prueba mensuales.
Preview Controles de protección contra congelamiento Intermatic PF1102T/PF1102MT: Manual de instalación, funcionamiento y servicio
Guía completa para la instalación, el funcionamiento y el mantenimiento de los controles de protección anticongelante Intermatic PF1102T y PF1102MT para piscinas y spas. Incluye advertencias de seguridad, diagramas de cableado y solución de problemas.
Preview Manual de instalación, funcionamiento y servicio del control de equipos para piscinas Intermatic PF1112T
Guía completa del control de equipos para piscinas Intermatic PF1112T, que detalla su instalación, funcionamiento y mantenimiento. Incluye protección contra congelamiento para piscinas y spas, temporizador de 24 horas e instrucciones de seguridad.
Preview Manual del propietario del temporizador portátil de alta resistencia para piscinas y spas Intermatic P1131
Manual del usuario del temporizador portátil de alta resistencia Intermatic P1131 para piscinas y spas. Incluye instrucciones de instalación, advertencias de seguridad, guía de solución de problemas e información sobre la garantía para un funcionamiento cómodo y eficiente de los equipos de piscinas y spas.
Preview Manual de instalación, funcionamiento y servicio del control de protección contra congelamiento Intermatic PF1102/PF1102M
Comprehensive installation, operation, and service manual for the Intermatic PF1102 and PF1102M Freeze Protection Controls, designed for pools, spas, and water features. Includes safety instructions, wiring diagrams, troubleshooting, and warranty information.
Preview Intermatic PF1100 Series Freeze Protection Controls: Installation, Operation & Service Manual
Comprehensive guide for Intermatic PF1100 Series Freeze Protection Controls (Models PF1102T, PF1102MT, PF1103MT). Covers installation, operation, safety warnings, troubleshooting, and warranty information for pool and spa equipment.