Intermatic EI400C

Intermatic EI400C Electronic Countdown In-Wall Timer User Manual

Model: EI400C

1. Introducción

The Intermatic EI400C Electronic Countdown In-Wall Timer is designed to provide automatic shut-off functionality for various electrical loads, including indoor and outdoor lighting, bathroom fans, whole house fans, and other appliances. This timer offers precise control from 1 second to 24 hours, enhancing convenience and energy efficiency in your home or office. Its silent operation and simple push-button interface make it user-friendly, while its no-neutral wire requirement simplifies installation in most standard wall boxes.

2. Información importante de seguridad

WARNING: Risk of Electric Shock. Improper installation can lead to serious injury or death.

  • Siempre apague la energía en el disyuntor o la caja de fusibles antes de instalar o realizar mantenimiento al temporizador.
  • Installation should be performed by a qualified electrician or in accordance with all local and national electrical codes.
  • Do not use this timer with sunlamps, saunas, or any loads that could cause personal injury if timed incorrectly or if the timer malfunctions.
  • Asegúrese de que todas las conexiones de cables estén seguras y adecuadamente aisladas.
  • Este dispositivo está diseñado únicamente para uso en interiores.

3. Producto terminadoview

The Intermatic EI400C is an electronic countdown timer designed for in-wall installation. It features a digital display and intuitive controls for setting countdown durations.

3.1 Componentes

  • Pantalla digital: Shows current time and countdown status.
  • Botón de encendido/apagado: Activates or deactivates the timer.
  • Botones más (+) / menos (-): Adjust countdown duration.
  • Botón de pausa: Temporarily stops the countdown.
  • Compartimento de la batería: Alberga la batería de litio CR2.

3.2 Imágenes del producto

Intermatic EI400C Timer installed with wall plate
Figura 1: Intermatic EI400C Electronic Countdown Timer installed in a wall plate, showing the digital display.
Frente view of Intermatic EI400C Timer without wall plate
Figura 2: Frente view of the EI400C timer module, revealing its compact design before wall plate installation.
Lado view of Intermatic EI400C Timer showing wiring details
Figura 3: Lado view of the EI400C timer, illustrating the wiring terminals and load ratings printed on the side.
Intermatic EI400C Timer with front cover open, revealing control buttons
Figura 4: The EI400C timer with its front cover opened, exposing the 'pause', 'on/off', and adjustment buttons for programming.

4. Configuración e instalación

The Intermatic EI400C timer is designed for easy installation, compatible with single-pole or 3-way switch configurations and does not require a neutral wire connection.

4.1 Pasos previos a la instalación

  1. Apague la energía: Locate the circuit breaker or fuse that controls the switch you are replacing and turn off the power. Verify power is off using a voltage probador.
  2. Eliminar el interruptor existente: Retire con cuidado la placa de pared y desatornille el interruptor existente de la caja de pared. Desconecte los cables del interruptor antiguo.

4.2 Instrucciones de cableado

The EI400C timer is compatible with both single-pole and 3-way switch setups. Refer to the diagram provided with your product for specific wiring configurations. Generally, the timer will have two load wires and a ground wire. For 3-way applications, one of the traveler wires from the existing 3-way switch will be connected to the timer.

  • Connect the timer's wires to the corresponding house wires using wire nuts.
  • Asegúrese de que todas las conexiones estén firmes y seguras.
  • The EI400C does not require a neutral wire, simplifying installation in older homes.

4.3 Mounting and Finalizing Installation

  1. Carefully push the wired timer into the wall box.
  2. Secure the timer to the wall box with the provided screws.
  3. Coloque la placa de pared decorativa.
  4. Restaurar energía: Vuelva a encender la energía en el disyuntor.

4.4 Instalación de la batería

The timer comes with a replaceable CR2 lithium battery, which powers the internal clock and settings memory. The battery is typically pre-installed or needs to be inserted upon initial setup.

  • Open the small front cover of the timer to access the battery compartment.
  • Insert the CR2 lithium battery, observing the correct polarity.
  • Cierre bien la tapa del compartimento de la batería.

5. Instrucciones de funcionamiento

The EI400C timer offers simple, push-button operation for setting countdown durations from 1 second to 24 hours.

5.1 Setting a Countdown Time

  1. Controles de acceso: Gently open the front cover of the timer to reveal the control buttons.
  2. Ajustar hora: Utilice el + y - buttons to set the desired countdown duration. The display will show the selected time.
  3. Temporizador de inicio: Presione el Encendido/apagado button to activate the timer. The connected load will turn on, and the timer will begin counting down.

5.2 Turning Off Before Countdown Ends

If you wish to turn off the connected load before the set countdown time expires, simply press the Encendido/apagado button again. This will immediately turn off the load and reset the timer.

5.3 Función de pausa

Presione el Pausa button to temporarily halt the countdown. The connected load will remain on. Press Pausa de nuevo para reanudar la cuenta atrás.

5.4 Lockable Settings

The timer features lockable settings to prevent unintended changes to the program. Refer to the detailed instructions included in the product packaging for how to activate and deactivate this feature.

5.5 Visual/Audible Warnings

The EI400C can be configured to provide a visual or audible warning before the timer turns off. Consult the full product manual for steps on enabling and customizing these warning options.

5.6 Vídeo instructivo

Vídeo 1: An official Intermatic video providing an overview of their in-wall timers, including the EI400 series. This video demonstrates general features and benefits of Intermatic in-wall timers, which are applicable to the EI400C model.

6. Mantenimiento

The Intermatic EI400C timer requires minimal maintenance, primarily focusing on battery replacement.

6.1 Reemplazo de batería

The internal CR2 lithium battery provides power for the timer's memory and display, typically lasting up to three years. When the battery is low, a 'LoBatt' indicator may appear on the display.

  1. Open the front cover of the timer.
  2. Retire con cuidado la batería CR2 vieja de su compartimento.
  3. Inserte una nueva batería de litio CR2, asegurándose de la polaridad correcta.
  4. Cierre la cubierta frontal de forma segura.

Nota: Some users have reported that the battery compartment cover can be difficult to open or may not stay securely closed after multiple battery changes. Exercise care when opening and closing the compartment. If the cover does not stay closed, ensure the battery makes proper contact.

7. Solución de problemas

This section addresses common issues you might encounter with your Intermatic EI400C timer.

ProblemaPosible causaSolución
Timer display is blank or shows 'LoBatt'Low or dead CR2 battery, or poor battery contact.Replace the CR2 lithium battery. Ensure the battery is inserted correctly and the compartment cover is securely closed to maintain contact.
Timer shows 'NoOP' errorIndicates a problem with battery contact or internal operation.Check and re-seat the CR2 battery. If the issue persists, the unit may require replacement.
Connected load does not turn on/offNo power to the timer, incorrect wiring, or faulty load.Verify power at the circuit breaker. Double-check wiring connections according to the installation instructions. Test the connected load (e.g., light bulb) with a different switch or power source.
Difficulty opening battery compartment coverTight fit or worn plastic tabs.Use a small, flat-head screwdriver to gently pry open the cover. Be careful not to damage the plastic tabs.
Timer does not hold settings after power outageDead or missing CR2 battery.The CR2 battery maintains settings during power outages. Ensure it is installed and functional.

8. Especificaciones

CaracterísticaDetalle
Número de modeloEI400C
MarcaIntermático
ColorMarfil
MaterialPlástico
Volumentage120 277-VAC
Carga máxima20 Amps
Rango del temporizador1 Second to 24 Hours
Tipo de interruptorUnipolar o de 3 vías
Tipo de montajeStandard Wall Box, Rectangular Decorator Wall Plate
Batería requerida1 CR2 Lithium (included)
Duración de la bateríaHasta 3 años
Dimensiones4.13 x 1.75 x 1.2 pulgadas
Peso del artículo6 onzas (0.38 libras)
Proceso de dar un títuloCSA certificado
Código Postal078275101371

9. Garantía y soporte

9.1 Información de garantía

The Intermatic EI400C Electronic Countdown In-Wall Timer comes with a Garantía limitada de 5 añosEsta garantía cubre defectos de materiales y mano de obra en condiciones normales de uso. Conserve su comprobante de compra para reclamaciones de garantía.

9.2 Atención al cliente

Para asistencia técnica, resolución de problemas adicionales a los que se describen en este manual o consultas sobre la garantía, comuníquese con el servicio de atención al cliente de Intermatic. Consulte el sitio web oficial de Intermatic. websitio o el embalaje del producto para obtener la información de contacto más actualizada.

Recursos en línea: Visita el Tienda Intermatic en Amazon Para obtener información adicional sobre el producto y recursos.

Documentos relacionados - EI400C

Preview Temporizador digital para exteriores Intermatic HB880R de 7 días: Instrucciones de funcionamiento y guía de configuración
Manual de usuario completo del temporizador digital de 7 días para exteriores Intermatic HB880R. Aprenda a instalar, programar, configurar horarios y solucionar problemas de este versátil interruptor horario.
Preview Temporizador electrónico de pared Intermatic EI200: Guía de instalación y funcionamiento
Guía detallada del temporizador electrónico de pared Intermatic EI200. Incluye información sobre características, especificaciones, pasos de instalación, modos de funcionamiento (modo temporizador, modo de retención) y garantía limitada de 1 año. Contiene diagramas de cableado y advertencias de seguridad.
Preview Control de temporizador electrónico Intermatic ET8215C - Datos técnicos
Especificaciones técnicas detalladas para el control temporizador electrónico Intermatic ET8215C, un control electrónico astronómico de 2 circuitos y 7 días adecuado para aplicaciones de 120 a 277 VCA en un gabinete metálico para interiores.
Preview Intermatic EI400 Series Digital Auto Shut-Off Timer: Installation and User Instructions
Comprehensive installation and user guide for the Intermatic EI400 Series Digital Auto Shut-Off Timer. Learn how to install, set up, and troubleshoot this electronic timer for controlling lights and appliances, with detailed wiring instructions and operational tips.
Preview Temporizadores digitales de pared Intermatic serie ST01: Especificaciones y características
Especificaciones detalladas, características, clasificaciones y diagramas de instalación de los temporizadores digitales de pared Intermatic serie ST01. Temporizadores fáciles de programar con funciones astronómicas para la conmutación al amanecer y al atardecer.
Preview Temporizador de pared para interiores Intermatic EJ351: Instrucciones de instalación y uso
Este documento proporciona instrucciones de instalación y uso para el temporizador de pared para interiores Intermatic EJ351. Abarca las especificaciones, el cableado, los métodos de programación (rápido y de 24 horas), el uso diario, la resolución de problemas y una garantía limitada de un año.