1. Introducción
The Riello IDG 1200 is a compact and reliable Uninterruptible Power Supply (UPS) designed to protect your electronic devices from power outages and fluctuations. It provides a stable power source, ensuring continuous operation and safeguarding your equipment from potential damage. This manual provides essential information for the proper installation, operation, and maintenance of your Riello IDG 1200 UPS.

This image shows the Riello IDG 1200 UPS unit from a front-side angle. The device is black, compact, and designed for vertical placement. The front panel features the 'Riello iDialog UPS' logo. Ventilation grilles are visible on the side.
2. Configuración
2.1 Desembalaje
Carefully remove the UPS from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. Retain the packaging for future transport or storage.
2.2 Colocación
Due to its compact form factor, the Riello IDG 1200 can be positioned almost anywhere. Ensure the chosen location is:
- Well-ventilated, allowing for proper heat dissipation.
- Away from direct sunlight, heat sources, and excessive humidity.
- Sobre una superficie estable y plana.
2.3 Conexión del SAI
- Conecte el cable de alimentación del UPS a un tomacorriente de pared con conexión a tierra.
- Connect your computer, monitor, and other critical devices to the output sockets on the rear of the UPS. Ensure the total power consumption of connected devices does not exceed the UPS's capacity (720W).
- For advanced monitoring and management, connect the UPS to your computer via the appropriate communication port (e.g., USB, if available).
2.4 Instalación del software (opcional)
The Riello IDG 1200 is compatible with various operating systems, including Windows Vista, 2003, XP, 2000, Me, 98, Linux, Mac OSX, and Sun Solaris. For enhanced control and monitoring features, install the Riello UPS management software on your computer. Refer to the software's documentation for installation instructions.
3. Instrucciones de funcionamiento
3.1 Encendido del UPS
Press and hold the power button on the front panel for a few seconds until you hear a beep and the indicators light up. The UPS will perform a self-test and then enter normal operating mode.
3.2 Powering Off the UPS
To turn off the UPS, press and hold the power button again until the indicators turn off and you hear a final beep. Ensure all connected devices are properly shut down before turning off the UPS.
3.3 Reinicio automático
The Riello IDG 1200 features an automatic restart function. After a power outage and when utility power is restored, the UPS will automatically restart and resume providing power to connected devices, provided the battery has sufficient charge.
3.4 Modo Batería
When utility power fails, the UPS will automatically switch to battery mode, providing backup power to connected devices. An audible alarm may sound to indicate that the UPS is operating on battery power. The alarm will typically become more frequent as the battery charge depletes.
4. Mantenimiento
4.1 Cuidado de la batería
The UPS contains sealed lead-acid batteries. To maximize battery life:
- Keep the UPS connected to a power outlet to ensure the batteries remain fully charged.
- Avoid storing the UPS in extreme temperatures.
- Perform a battery self-test periodically (if supported by the management software) to assess battery health.
- The typical battery recharge time is approximately 8 hours.
4.2 Limpieza
Clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and obstructions.
4.3 Reemplazo de batería
Battery replacement should only be performed by qualified service personnel. Refer to the manufacturer's guidelines for battery replacement procedures and compatible battery types.
5. Solución de problemas
This section provides solutions to common issues you might encounter with your Riello IDG 1200 UPS. If the problem persists after attempting these solutions, please contact customer support.
| Problema | Posible causa | Solución |
|---|---|---|
| El UPS no se enciende. | No input power; Battery deeply discharged. | Ensure the power cord is securely plugged into a live wall outlet. Allow the UPS to charge for at least 8 hours before attempting to turn it on. |
| El UPS emite un pitido continuo en modo normal. | Condición de sobrecarga. | Disconnect non-essential equipment from the UPS until the alarm stops. Ensure total load does not exceed 720W. |
| El UPS cambia al modo de batería con frecuencia. | Energía eléctrica inestable; configuración de sensibilidad demasiado alta. | Check your utility power supply. If using management software, adjust the UPS sensitivity setting (refer to software manual). |
| Tiempo de respaldo corto. | La batería es vieja o no está completamente cargada; Sobrecarga. | Allow the UPS to charge for 8 hours. Reduce the connected load. Consider battery replacement if the battery is old. |
6. Especificaciones
| Característica | Especificación |
|---|---|
| Marca | Riello |
| Número de modelo | IDG 1200 |
| Serie | iDialog |
| Capacidad de potencia de salida | 1200 VA / 720 W |
| Volumentage | 1200 Volts (Input/Output nominal) |
| Color | Negro |
| Material | Metal |
| Dimensiones del producto | 9.3 x 31 x 27 cm |
| Peso del artículo | 3.7 kilogramos |
| Tipo de batería | Lead Acid, AGM |
| Tiempo de recarga de la batería | 8 horas |
| Factor de forma | Compacto |
| Primera fecha disponible | 3 de enero de 2012 |
7. ¿Qué hay en la caja?
The Riello IDG 1200 package typically includes:
- Riello IDG 1200 UPS Unit
- Cables de alimentación
- Manual de usuario (este documento)
- Communication Cable (e.g., USB cable for software connection)
8. Garantía y soporte
Para obtener información sobre la garantía, asistencia técnica o consultas de servicio, consulte la tarjeta de garantía incluida con su producto o visite el sitio web oficial de Riello. webSitio. Conserve su recibo de compra como comprobante para reclamaciones de garantía.
Riello Oficial Websitio: www.riello-ups.es