Morris 97434

Manual de instrucciones del conector multicable con aislamiento transparente Morris Products 97434

Modelo: 97434

1. Introducción

This instruction manual provides essential information for the proper installation, operation, and maintenance of the Morris Products 97434 Clear Insulated Multi-Cable Connector. Please read this manual thoroughly before installation to ensure safe and efficient use. This connector is designed for joining multiple electrical conductors within a specified wire range.

2. Información de seguridad

ADVERTENCIA: Electrical work should only be performed by qualified personnel. Failure to follow these instructions can result in electrical shock, fire, or serious injury.

3. Características del producto

4. Configuración e instalación

Follow these steps for proper installation of the multi-cable connector:

  1. Desconexión de energía: Ensure all power to the circuit is completely disconnected and locked out before beginning installation. Verify with a voltage probador.
  2. Preparación del alambre: Strip the insulation from the conductor ends to the appropriate length, ensuring that the bare wire will fully enter the connector port without excess insulation inside or bare wire exposed outside. Refer to local electrical codes for specific stripping length requirements.
  3. Conductor Insertion: Insert one prepared conductor into each port of the connector. The clear insulation allows for visual confirmation that the conductor is fully seated and making proper contact with the internal metal barrel.
Morris Products 97434 Clear Insulated Multi-Cable Connector, showing the clear body and three wire entry ports.

Figura 1: Sobreview of the Morris Products 97434 Multi-Cable Connector.

  1. Apretar conexiones: Use an appropriate hex wrench to tighten the set screws for each conductor. Tighten until the wire is securely held and the connection is firm. Do not overtighten.
De cerca view of the Morris Products 97434 connector ports, showing the internal set screws and pre-filled oxide inhibitor.

Figure 2: Close-up of connector ports with set screws and oxide inhibitor.

  1. Inspección visual: After tightening, visually inspect each connection through the clear insulation to confirm that the conductor is properly seated and the connection appears secure.
  2. Re-entry Plugs: The connector features removable plugs marked with wire size, providing easy access for installation, inspection, or troubleshooting. Ensure these plugs are securely in place after installation.
  3. Restauración de energía: Once all connections are verified as correct and secure, restore power to the circuit.

5. Instrucciones de funcionamiento

Once installed, the Morris Products 97434 connector operates passively to maintain electrical continuity. No user interaction is required during normal operation. The clear insulation allows for ongoing visual inspection of the connections without disassembly.

6. Mantenimiento

Periodic inspection of the connector is recommended to ensure continued integrity of the electrical connections. Check for:

If any issues are observed, disconnect power immediately and address the problem by re-terminating the connection or replacing the connector if damaged.

7. Solución de problemas

Most issues related to electrical connectors stem from improper installation. If a circuit connected with the 97434 connector is not functioning correctly:

8. Especificaciones

EspecificaciónDetalle
Número de modelo97434
Gama de cables500-4 AWG
Número de puertos3
Volumentage Calificación600 voltios
Material6061-T6 Aluminum, Copper
Material de aislamientoCloruro de polivinilo (PVC)
Rango de temperatura-49 °F a 194 °F (-45 °C a 90 °C)
Dimensiones4.13 x 3.38 x 2.75 pulgadas
Peso12.8 onzas
CertificacionesANSI C119.4, cULus 486b Listed

9. Garantía y soporte

For warranty information or technical support regarding the Morris Products 97434 Clear Insulated Multi-Cable Connector, please contact Morris Products directly through their official webSitio web o canales de atención al cliente. Conserve su recibo de compra para cualquier reclamación de garantía.

Documentos relacionados - 97434

Preview Morris Monthly - Junio ​​de 2009 - Boletín informativo del Morris Register
La edición de junio de 2009 de Morris Monthly, el boletín oficial del club Morris Register, que incluye noticias del club, historias de miembros, artículos técnicos e informes de eventos para los entusiastas de los vehículos Morris.
Preview Morris LED Floodlight Installation Guide and Safety Instructions
Comprehensive installation guide for Morris LED Floodlights, covering safety warnings, step-by-step instructions, and symbol explanations. Ensure safe and correct setup.
Preview Unidades interiores de pared MORRIS Multi Series - Información técnicaview
Especificaciones técnicas y más.view para unidades de aire acondicionado interiores montadas en la pared MORRIS Multi Series, incluidos los modelos MMSI-26001, MMSI-35002 y MMSI-50003.
Preview Manual de usuario de MORRIS MPH-20041S para conexión WiFi
Manual de usuario del dispositivo MORRIS MPH-20041S, que detalla cómo conectarlo a una red Wi-Fi mediante la aplicación Tuya Smart. Abarca el registro, la configuración de red (manual y búsqueda por dispositivo) y las funciones básicas de control del dispositivo.
Preview Manual de usuario y configuración del purificador de aire Morris MAP-36310 con WiFi
Una guía completa para conectar y controlar el purificador de aire Morris MAP-36310 mediante WiFi a través de la aplicación Tuya Smart, que incluye instrucciones de configuración, resolución de problemas y funciones del dispositivo.
Preview Manual de usuario y guía de instalación de la placa vitrocerámica empotrada MORRIS MVD-65352
Este documento proporciona instrucciones completas para la placa vitrocerámica empotrada MORRIS MVD-65352, incluidas pautas de seguridad, especificaciones técnicas, procedimientos de instalación, instrucciones de funcionamiento, consejos de limpieza y mantenimiento y consejos para la solución de problemas.