AUTONICS AT11DN-24-240

Manual de instrucciones del temporizador multifunción AUTONICS AT11DN-24-240

Model: AT11DN-24-240 | Brand: AUTONICS

1. Introducción

This manual provides essential information for the safe and effective installation, operation, and maintenance of the AUTONICS AT11DN-24-240 Multi-Function Timer. This device is designed for precise timing control in various industrial and commercial applications, offering a wide timing range from 0.05 seconds to 100 hours and operating on 100VAC-240VAC power.

2. Precauciones de seguridad

Read these safety precautions carefully before using the product to ensure proper and safe operation. Failure to follow these instructions may result in electric shock, fire, or product damage.

  • Seguridad eléctrica: Ensure all wiring is performed by qualified personnel in accordance with local and national electrical codes. Disconnect power before installation, inspection, or maintenance.
  • Fuente de alimentación: Verifique que el volumen de la fuente de alimentacióntage coincide con el volumen especificado del productotage range (100VAC-240VAC). Incorrect voltagPuede causar daños.
  • Entorno de instalación: Install the timer in an environment free from excessive vibration, dust, moisture, corrosive gases, or direct sunlight. Ensure adequate ventilation.
  • Conexiones de terminales: Securely fasten all terminal connections to prevent loose contacts, which can lead to overheating or malfunction.
  • Capacidad de carga: Do not exceed the specified contact rating (5A resistive load). Overloading can damage the internal relay.

3. Producto terminadoview

The AUTONICS AT11DN-24-240 is a compact multi-function timer featuring a clear rotary dial for time setting and various indicators for operational status.

Frente view of the AUTONICS AT11DN-24-240 Multi-Function Timer showing the control dial, power and run indicators, and mode selector.

Figure 1: Front panel of the AUTONICS AT11DN-24-240 Multi-Function Timer.

This image displays the front panel of the AUTONICS AT11DN-24-240 Multi-Function Timer. Visible elements include the central rotary dial for time setting, marked with a scale from 0 to 10. Above the dial, there are 'POWER' and 'RUN' indicator lights. To the right, an 'OUT' indicator and a 'MODE' selector switch are present. The brand name 'Autonics' is printed at the bottom right of the panel.

3.1. Componentes del panel frontal

  • Time Setting Dial: Rotary dial for setting the desired time value within the selected range.
  • Indicador de encendido: Illuminates when power is supplied to the timer.
  • Indicador de FUNCIONAMIENTO: Illuminates during the timing operation.
  • Indicador de SALIDA: Illuminates when the output relay is activated.
  • Selector de MODO: Switch to select the desired operating mode (e.g., ON-delay, Interval).

4. Configuración

4.1. Montaje

The AT11DN-24-240 timer is designed for panel mounting. Ensure sufficient space for wiring and ventilation. Secure the timer using the provided mounting hardware.

4.2. cableado

Refer to the wiring diagram printed on the side of the timer or in the detailed product datasheet for specific terminal connections. Common connections include:

  • Power Supply (100-240VAC): Conecte la fuente de alimentación principal a los terminales designados.
  • Contactos de salida: Connect the load to the normally open (NO) and common (COM) terminals of the output relay. Ensure the load current does not exceed 5A resistive.
  • Control Input (if applicable): Some modes may utilize external control inputs (e.g., START, RESET). Connect these as per the specific mode's requirements.

Warning: Ensure power is disconnected before performing any wiring.

4.3. Ajustes iniciales

  • Selección de rango de tiempo: The timer supports various time ranges (e.g., seconds, minutes, hours). Select the appropriate range using the internal DIP switches or external selector, if present (refer to the detailed product datasheet for specific model configuration).
  • Selección del modo de funcionamiento: Use the 'MODE' selector switch on the front panel to choose the desired timing function (e.g., ON-delay, OFF-delay, Interval, Flicker).

5. Instrucciones de funcionamiento

5.1. Configuración de la hora

Rotate the central time setting dial to the desired time value. The dial is typically marked with a scale from 0 to 10, representing a percentage of the selected time range. For example, if the range is 10 minutes, setting the dial to '5' would correspond to 5 minutes.

5.2. Encendido

Once wiring and settings are complete, apply power to the timer. The 'POWER' indicator will illuminate.

5.3. Timing Operation

Depending on the selected mode:

  • For ON-delay mode, timing begins immediately upon power application or trigger. The 'RUN' indicator will illuminate.
  • Upon completion of the set time, the output relay will activate, and the 'OUT' indicator will illuminate.
  • For other modes, refer to the specific timing chart in the detailed product datasheet.

6. Mantenimiento

The AUTONICS AT11DN-24-240 timer is designed for long-term, reliable operation with minimal maintenance. However, periodic checks can help ensure optimal performance.

  • Limpieza: Gently wipe the exterior of the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Inspección: Periodically inspect wiring connections for tightness and signs of wear or damage. Check for any unusual sounds or odors during operation.
  • Almacenamiento: If storing the timer, keep it in a dry, dust-free environment within the specified temperature and humidity ranges.

7. Solución de problemas

If the timer does not operate as expected, consult the following table before contacting support.

ProblemaPosible causaSolución
Timer does not power on (POWER indicator off)No power supply; Incorrect wiring; Blown fuse (external)Check power source; Verify wiring connections; Inspect external fuse.
Timing does not start (RUN indicator off)Incorrect mode selection; No trigger signal (if applicable); Faulty unitVerify operating mode; Check trigger input; Contact support if unit is faulty.
Output does not activate (OUT indicator off)Timing not complete; Incorrect load wiring; Overloaded outputWait for timing cycle to complete; Check load connections; Ensure load current is within 5A resistive.
Sincronización inexactaIncorrect time setting; Incorrect time range selectionAdjust time setting dial; Verify time range selection.

8. Especificaciones

Key technical specifications for the AUTONICS AT11DN-24-240 Multi-Function Timer:

CaracterísticaEspecificación
Número de modeloAT11DN-24-240
MarcaAUTONICS
Intervalo de tiempo0.05 segundos a 100 horas
Vol de suministrotage100VAC - 240VAC
Consumo de energía1.5 W
Tipo de salidaRelay Output (1c)
Calificación de contacto5A Resistive Load
Tiempo de reinicio100 ms
MaterialPlástico
Dimensiones del paquete4.49 x 3.19 x 2.28 pulgadas
Peso del artículo4.41 onzas

9. Garantía y soporte

AUTONICS products are manufactured under strict quality control standards. For specific warranty terms and conditions, please refer to the warranty information provided with your purchase or visit the official AUTONICS website. For technical assistance, troubleshooting beyond this manual, or repair services, please contact AUTONICS customer support or your authorized distributor.

Documentos relacionados - AT11DN-24-240

Preview Autonics LE7M-2 Series LCD Week/Year Digital Timer Instruction Manual
Detailed instruction manual for Autonics LE7M-2 Series digital timers, covering W 72xH 72mm LCD display, weekly/yearly programming, safety, specifications, and installation. Includes LE7M-2B and LE7M-2D models.
Preview Autonics ATM Series Analog Timers Catalog
Comprehensive catalog detailing the Autonics ATM Series of miniature analog timers. Includes specifications, ordering information, features, dimensions, and pin arrangements for models ATM4-2, ATM4-5, and ATM4-6.
Preview Manual de instrucciones de los temporizadores analógicos Autonics serie ATS (ancho 38 x alto 42 mm) | Especificaciones técnicas
Manual de instrucciones detallado y especificaciones técnicas de los temporizadores analógicos Autonics Serie ATS de 38 mm de ancho x 42 mm de alto. Incluye modos de funcionamiento, rangos de tiempo, dimensiones, conexiones y especificaciones eléctricas para los modelos ATS11, ATS11-TD y ATS11-TF.
Preview Autonics Multi Pulse Meters MP5S/MP5Y/MP5W Series Product Manual
This product manual provides detailed information on Autonics MP5S, MP5Y, and MP5W series multi pulse meters, covering features, safety guidelines, ordering, specifications, operation modes, functions, and connection exampLes.
Preview Manual de instrucciones de los temporizadores digitales con interruptor de rueda giratoria y pantalla LCD de la serie Autonics LE3S
Manual de instrucciones para los temporizadores con interruptor de rueda digital LCD de la serie Autonics LE3S, que incluye información sobre pedidos, componentes del producto, dimensiones, consideraciones de seguridad, precauciones durante el uso, especificaciones, modos de funcionamiento de salida, rangos de tiempo, conexiones y modo ARRIBA/ABAJO.
Preview Manual de instrucciones de los temporizadores digitales LCD de la serie LE4S de Autonics
Manual de instrucciones para los temporizadores digitales LCD de la serie Autonics LE4S, que abarca consideraciones de seguridad, información para pedidos, dimensiones, descripciones de la unidad, modos de funcionamiento de salida, configuración de parámetros, conexiones y especificaciones detalladas.