Amprobe AM-570

Amprobe AM-570 Industrial Digital Multimeter User Manual

1. Introducción

This manual provides essential instructions for the safe and effective operation of the Amprobe AM-570 Industrial Digital Multimeter. The AM-570 is designed for professionals requiring accurate and reliable measurements in various electrical, HVAC/R, and industrial maintenance applications. Please read this manual thoroughly before using the device to ensure proper function and safety.

2. Información de seguridad

Para evitar descargas eléctricas o lesiones personales, y evitar daños al medidor o al equipo bajo prueba, observe las siguientes pautas de seguridad:

3. Contenido del paquete

Verifique que todos los elementos enumerados a continuación estén presentes y sin daños:

Amprobe AM-570 Multimeter and accessories including test leads, thermocouple probes, and carrying case

Imagen 3.1: La Amprobe AM-570 Digital Multimeter shown with its standard accessories, including test leads, two K-type thermocouple probes, and a soft carrying case.

4. Características del producto

El Amprobe AM-570 offers a comprehensive set of features for diverse electrical measurements:

Frente view of Amprobe AM-570 Digital Multimeter displaying 119.4 V DC

Imagen 4.1: La Amprobe AM-570 Digital Multimeter, showing its display, rotary dial, and function buttons. The display indicates a DC voltage reading of 119.4 V.

Angular view of Amprobe AM-570 Digital Multimeter displaying 0.000 kHz

Imagen 4.2: Un ángulo view del Amprobe AM-570 Digital Multimeter, highlighting the clear digital display, which currently shows a frequency reading of 0.000 kHz.

5. Configuración

5.1 Instalación de la batería

  1. Asegúrese de que el medidor esté apagado.
  2. Localice el compartimiento de la batería en la parte posterior del medidor.
  3. Utilice un destornillador para aflojar el tornillo que fija la tapa de la batería.
  4. Retire la tapa de la batería.
  5. Inserte una batería nueva de 9 V, observando la polaridad correcta.
  6. Vuelva a colocar la tapa de la batería y asegúrela con el tornillo.

5.2 Conexión de cables de prueba

Always connect the black test lead to the COM (common) terminal. Connect the red test lead to the appropriate input terminal based on the measurement function:

Lado view of Amprobe AM-570 Digital Multimeter with kickstand extended

Imagen 5.1: La Amprobe AM-570 Digital Multimeter shown with its integrated kickstand extended, allowing for hands-free viewing durante el funcionamiento.

6. Instrucciones de funcionamiento

The AM-570 features a rotary dial for selecting primary measurement functions and push buttons for secondary functions and settings.

6.1 Selección de función

Turn the rotary dial to the desired measurement function. Use the SELECCIONAR button to toggle between primary and secondary functions within a single dial position (e.g., AC/DC voltage, resistencia/continuidad/diodo).

6.2 Funciones de medición

6.3 Funciones especiales

Electrician using Amprobe AM-570 Digital Multimeter to measure voltage en un panel eléctrico

Image 6.1: An electrician utilizing the Amprobe AM-570 Digital Multimeter to perform voltage measurements within an industrial electrical panel, demonstrating practical application.

7. Mantenimiento

7.1 Limpieza

Limpie el medidor con publicidadamp Paño y detergente suave. No utilice abrasivos ni disolventes. Asegúrese de que el medidor esté seco antes de usarlo.

7.2 Reemplazo de batería

Refer to Section 5.1 for detailed instructions on replacing the 9V battery. Replace the battery promptly when the low battery indicator appears on the display.

7.3 Reemplazo de fusibles

If the current measurement functions cease to operate, the internal fuses may need replacement. Fuse replacement should only be performed by qualified personnel. Refer to the full service manual for fuse specifications and replacement procedures. Always use fuses with the specified voltage y calificaciones actuales.

7.4 Almacenamiento

When not in use for extended periods, remove the battery to prevent leakage. Store the meter in a cool, dry environment, preferably in its carrying case.

8. Solución de problemas

ProblemaPosible causaSolución
El medidor no se enciendeBatería agotada o mal instaladaCheck battery polarity; replace battery (see Section 5.1).
No se muestra ninguna lectura o se muestra "OL" (sobrecarga)Incorrect function selected; open circuit; measurement range exceededVerify function switch position; check circuit continuity; select a higher range or auto-range.
Lecturas inexactasLow battery; dirty test leads/terminals; external interferenceReplace battery; clean leads and terminals; move away from strong electromagnetic fields.
La medición actual no funcionaFusible fundidoReplace fuse (see Section 7.3).
NCV function inconsistentEnvironmental factors; sensor positionEnsure direct proximity to live conductor; NCV is for indication only, use test leads for precise voltagy verificación.

9. Especificaciones

ParámetroDetalle
ModeloAM-570
FabricanteAmptúnica
Capacidades de mediciónVol. CA / CCtage, AC/DC Current, Resistance, Frequency, Capacitance, Temperature, Duty Cycle
Clasificación de seguridadCAT IV 600 V / CAT III 1000 V
Verdadero valor eficaz
Low Z Mode
Filtro de paso bajo
Fuente de poderBatería de 9 V
Dimensiones del producto4 x 10 x 2 pulgadas (10.16 x 25.4 x 5.08 cm)
Peso del artículo13.05 onzas (370 gramos)
ColorBlack with Red overmolding

10. Garantía y soporte

Amprobe products are designed for reliability and performance. This product is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Amptúnica websitio.

For technical support, service, or replacement parts, please contact Amprobe customer service. Contact information can typically be found on the Amptúnica websitio o en el embalaje del producto.

Documentos relacionados - AM-570

Preview AmpManual del usuario del multímetro robe AM-560 y AM-570
Manual de usuario completo para AmpMultímetro HVAC avanzado robe AM-560 y multímetro industrial AM-570, que cubren características, especificaciones, operación, mantenimiento y pautas de seguridad.
Preview Ampbata ACD-6 Pro y ACD-6 TRMS Pro Clamp-En el manual del usuario del multímetro
Manual de usuario completo para Ampbata ACD-6 Pro y ACD-6 TRMS Pro versátil clamp-Sobre multímetros, incluyendo seguridad, descripción del producto, funcionamiento, mantenimiento, especificaciones e información sobre la garantía.
Preview AmpManual de usuario del medidor de capacitancia y resistencia robe CR50A
Este manual de usuario proporciona instrucciones completas para el funcionamiento del AmpMedidor de capacitancia y resistencia robe CR50A: características, procedimientos de medición, pautas de seguridad y especificaciones técnicas.
Preview AmpManual de usuario del sistema localizador de cables/tuberías subterráneas robe AT-3500
Manual de usuario completo para el AmpSistema localizador de cables/tuberías subterráneas robe AT-3500, que detalla su funcionamiento, características, especificaciones técnicas y mantenimiento para una detección precisa de servicios públicos subterráneos.
Preview AmpManual de usuario del multímetro digital Robe AM-420
Manual de usuario del AmpMultímetro digital robe AM-420: descripción detallada de sus características, capacidades de medición, precauciones de seguridad y especificaciones para pruebas eléctricas. Apto para uso doméstico y profesional.
Preview AmpManual de usuario del termómetro infrarrojo robe IR-750 / IR-750-EUR 50:1
Manual de usuario del AmpTermómetros infrarrojos robe IR-750 e IR-750-EUR 50:1. Entre sus características destacan un amplio rango de temperatura, alta precisión, puntero láser, registro de datos y conectividad USB para aplicaciones industriales y profesionales.