System Sensor RTS151KEY

Manual del usuario de la estación de prueba remota System Sensor RTS151KEY

Model: RTS151KEY

1. Introducción

This manual provides comprehensive instructions for the installation, operation, and maintenance of the System Sensor RTS151KEY Remote Test Station. The RTS151KEY is designed as an accessory for duct smoke detectors, enabling remote testing and resetting capabilities.

Características principales:

2. Información de seguridad

Always adhere to local and national electrical codes and regulations during installation and operation. Only qualified personnel should perform installation and maintenance. Disconnect power before servicing the device.

Important Notice: DO NOT PAINT FIRE ALARM DEVICE. Painting may impair the device's functionality and compromise fire safety.

3. Configuración e instalación

The RTS151KEY is designed for easy installation. Ensure the mounting location is accessible and visible for testing and resetting. Refer to the specific duct smoke detector's manual for detailed wiring diagrams and compatibility.

Atrás view of System Sensor RTS151KEY showing wiring terminals and product label

Figura 3.1: Posterior view of the RTS151KEY showing wiring terminals and product information label. The label indicates "DC ONLY" and lists power requirements for the server (green LED) and alarm (red LED).

Instrucciones de cableado:

Connect the RTS151KEY to the compatible duct smoke detector using appropriate wiring. The terminals on the back of the unit are clearly labeled for connection. Ensure all connections are secure and comply with electrical standards.

Consult the duct smoke detector's installation manual for specific terminal assignments and wiring configurations.

4. Instrucciones de funcionamiento

The RTS151KEY provides remote control and status indication for the connected duct smoke detector. The front panel features a key switch and an alarm indicator LED.

Frente view of System Sensor RTS151KEY with key switch and alarm indicator

Figura 4.1: Frente view of the RTS151KEY Remote Test Station. It features a key switch with OFF, RESET, and TEST positions, and an ALARM indicator LED.

Funciones del interruptor de llave:

LED indicador de alarma:

5. Mantenimiento

The RTS151KEY requires minimal maintenance. Regular visual inspections are recommended to ensure the unit is free from damage and obstructions. Keep the surface clean using a soft, dry cloth. Do not use abrasive cleaners or solvents.

Periodic functional testing of the connected duct smoke detector via the RTS151KEY should be performed according to the manufacturer's recommendations and local fire codes.

6. Solución de problemas

ProblemaPosible causaSolución
Alarm LED does not illuminate during alarm.No power to the unit, faulty wiring, or faulty detector.Check power supply to the duct smoke detector. Verify wiring connections between RTS151KEY and detector. Test the detector directly if possible.
Key switch does not activate test/reset.Incorrect key operation, wiring issue, or detector malfunction.Ensure key is fully turned to TEST/RESET position. Check wiring. Consult duct smoke detector manual for troubleshooting.
Unit appears damaged.Physical impact or environmental factors.Do not attempt to repair. Contact System Sensor support or a qualified technician for replacement.

7. Especificaciones

AtributoDetalle
FabricanteSensor del sistema
Número de piezaRTS151CLAVE
Número de modelo del artículoCECOMINOD057176
Peso del artículo6.4 onzas
Dimensiones del producto2.76 x 1.8 x 4.61 pulgadas
ColorBlanco
FinalizarBlanco
Fuente de poderBattery-powered (Note: This might refer to the detector it connects to, as the RTS151KEY itself is typically powered by the detector's circuit)
Cantidad de artículos del paquete1
¿Baterias incluidas?No
¿Se requieren pilas?No
Fecha de primera disponibilidad4 de abril de 2012

Note: "Battery-powered" specification likely refers to the overall system the RTS151KEY integrates with, as the RTS151KEY itself is typically powered by the connected duct smoke detector.

8. Garantía y soporte

For warranty information and technical support, please contact System Sensor directly or refer to their official webSitio. Conserve su recibo de compra como comprobante de compra.

System Sensor Contact Information:

Documentos relacionados - RTS151CLAVE

Preview Guía de instalación y mantenimiento de la estación de prueba remota System Sensor RTS151KEY(-A)
Instrucciones detalladas de instalación y mantenimiento para la estación de prueba remota System Sensor RTS151KEY(-A), que abarcan especificaciones, funcionamiento, diagramas de cableado para varios detectores (D4120, DNR, D2, OSID, DH400ACDC, BEAM1224) e información de garantía.
Preview Instrucciones de instalación y mantenimiento de la estación de prueba remota System Sensor RTS151KEY(A)
Guía completa para la instalación y el mantenimiento de la estación de prueba remota System Sensor RTS151KEY(A), que incluye especificaciones, funcionamiento, diagramas de cableado para varios detectores e información de garantía.
Preview Estación de prueba remota System Sensor RTS151KEY: Guía de instalación y mantenimiento
Instrucciones completas de instalación y mantenimiento para la estación de prueba remota System Sensor RTS151KEY, incluidas especificaciones, detalles de funcionamiento y diagramas de cableado para varios detectores de humo de conductos y vigas.
Preview Estación de prueba remota RTS151KEY-A: Guía de instalación y mantenimiento
Instrucciones completas de instalación y mantenimiento para la estación de prueba remota System Sensor RTS151KEY-A, incluidas especificaciones, funcionamiento, diagramas de cableado e información de garantía.
Preview Instrucciones de instalación y mantenimiento de la estación de prueba remota System Sensor RTS151KEY(A)
Instrucciones de instalación y mantenimiento de la estación de prueba remota System Sensor RTS151KEY(A). Este documento proporciona especificaciones, detalles de funcionamiento, diagramas de cableado e información sobre la garantía del producto.
Preview Guía de inicio rápido del sistema de detección de humo System Sensor OSI-RI-SS
Guía de inicio rápido para la instalación del sistema de detección de humo System Sensor OSI-RI-SS, que abarca el posicionamiento de los componentes, el montaje, el cableado, la inicialización, las pruebas y la solución de problemas.