Generac 6346

Generac 6346 30-Amp 125/250V Aluminum Power Inlet Box Instruction Manual

Modelo: 6346 | Marca: Generac

1. Introducción

The Generac 6346 30-Amp 125/250-Volt Power Inlet Box is designed for safe and reliable outdoor connection of a portable generator to an indoor transfer switch. This NEMA 3R-rated, corrosion-resistant aluminum enclosure ensures secure power transfer to your home or building during electrical outages.

This power inlet box is compatible with Generac generators equipped with 30-Amp outlets, including models such as GP3250, LP3250, XG4000, XP4000, GP5500, GP6500E, GP7500E, XG6500, XG7000E, XG8000E, XP6500E, and XP8000E. It is also compatible with Generac transfer switches model numbers 6376, 6377, 6378, 6379, and 6382.

Generac 6346 Power Inlet Box, front view

Figure 1: Generac 6346 30-Amp Power Inlet Box.

2. Información de seguridad

ADVERTENCIA: Riesgo de descarga eléctrica o incendio.

  • Installation of this power inlet box must be performed by a qualified, licensed electrician in accordance with all applicable electrical codes and standards.
  • Do not attempt installation or wiring if you are not qualified. Improper installation can result in serious injury, death, or property damage.
  • Always disconnect all power sources before installing or servicing the power inlet box.
  • Ensure the generator is properly grounded before connecting it to the inlet box.
  • Never operate a generator indoors or in enclosed spaces. Generators produce carbon monoxide, a colorless, odorless, poisonous gas.

3. Configuración e instalación

The Generac 6346 Power Inlet Box is designed for exterior mounting on a house or building. It must be hardwired to an appropriate indoor transfer switch.

3.1. Ubicación de montaje

  • Select an outdoor location that is easily accessible for generator connection but protected from direct impact.
  • Ensure the location allows for proper routing of conduit and wiring to the indoor transfer switch.
  • The NEMA 3R rating provides protection against rain, sleet, and external ice formation.

3.2. Cableado y Conexión

  • The inlet box features 1/2-inch and 3/4-inch EMT knockouts for conduit entry.
  • Hardwire the inlet box to your transfer switch using appropriate gauge wiring for 30-Amp, 125/250V service.
  • Asegúrese de que todas las conexiones estén firmes y seguras.
Generac 6346 Power Inlet Box with dimensions

Figure 2: Dimensions of the Generac 6346 Power Inlet Box (approximately 6.7 inches in height).

4. Instrucciones de funcionamiento

Once the Generac 6346 Power Inlet Box is professionally installed and wired to your transfer switch, follow these steps to operate your generator during a power outage:

  1. Generador de posiciones: Place your portable generator outdoors in a well-ventilated area, away from windows, doors, and vents to prevent carbon monoxide accumulation.
  2. Conecte el cable de alimentación: Open the spring-loaded flip lid cover on the Generac 6346 Power Inlet Box. Connect a compatible Generac power cord (NEMA L14-30 configuration) from your 7500-Watt maximum generator to the inlet box. Ensure the connection is firm.
  3. Iniciar generador: Follow your generator's manufacturer instructions to start it. Allow the generator to run for a few minutes to stabilize.
  4. Transferencia de potencia: Go to your indoor transfer switch and follow its instructions to safely transfer power from the utility to the generator.
  5. Carga del monitor: No exceda la potencia nominal del generador.tage (7500 Watts maximum for this inlet box).
  6. Cerrar: When utility power is restored, reverse the transfer switch procedure to switch back to utility power. Then, shut down your generator according to its manual and disconnect the power cord from the inlet box. Close the flip lid cover.

5. Mantenimiento

The Generac 6346 Power Inlet Box is constructed from NEMA 3R-rated corrosion-resistant aluminum, designed for durability and minimal maintenance. Regular inspection is recommended to ensure continued safe operation.

  • Inspección visual: Periodically inspect the inlet box for any signs of physical damage, corrosion, or loose components.
  • Operación de la tapa: Ensure the spring-loaded flip lid cover opens and closes smoothly and seals properly to protect the inlet from weather elements. If the lid mechanism appears faulty, inspect for obstructions or damage.
  • Limpieza: Keep the exterior of the box clean from dirt, debris, and insect nests. Use a damp Paño para limpieza; evitar productos químicos agresivos.
  • Control profesional: Consider having a qualified electrician inspect your entire generator connection system periodically, especially after severe weather events.

6. Solución de problemas

This section addresses common issues you might encounter with the Generac 6346 Power Inlet Box. Always ensure the generator itself is functioning correctly before troubleshooting the inlet box.

ProblemaPosible causaSolución
No power to transfer switch after generator connection.
  • Generator not running or producing power.
  • Power cord not fully seated in inlet box or generator.
  • Transfer switch not correctly engaged.
  • Internal wiring issue (requires electrician).
  • Check generator fuel, oil, and start procedures.
  • Ensure power cord is securely plugged into both the inlet box and the generator.
  • Refer to your transfer switch manual for proper operation.
  • Contacte a un electricista calificado para una inspección.
Flip lid cover does not close or open smoothly.
  • Debris or obstruction in hinge mechanism.
  • Damaged spring or hinge.
  • Clean the hinge area.
  • Inspect for physical damage. If damaged, contact Generac support for replacement parts.
Visible damage to the inlet box.
  • Physical impact or environmental exposure.
  • Do not use if damaged. Contact a qualified electrician for assessment and replacement if necessary.

7. Especificaciones

  • Modelo: 6346
  • Ampedad: 30-Amp
  • Volumentage: 125/250 V
  • Maximum Generator Wattage: 7500 vatios
  • Configuración NEMA: L14-30
  • Material: Aluminio
  • Tipo de acabado: Pintado
  • Tipo de instalación: Atornillar
  • Dimensiones (L x An x Al): Aproximadamente 5 x 7 x 5 pulgadas
  • Peso del artículo: Aproximadamente 1.6 libras
  • Calificación Ambiental: NEMA 3R (Rain tight)
  • Certificaciones: Listado por UL
  • País natal: Hecho en EE.UU.

8. Información de garantía

The Generac 6346 30-Amp 125/250V Aluminum Power Inlet Box is backed by a Garantía limitada de 2 años. This warranty covers defects in materials and workmanship under normal use and service. For full warranty terms and conditions, please refer to the official Generac warranty documentation included with your product or visit the Generac websitio.

9. Atención al cliente

For technical assistance, warranty claims, or to inquire about replacement parts, please contact Generac Customer Service. Ensure you have your product model number (6346) and purchase date available when contacting support.

Generac Oficial Websitio: www.generac.com

Note: Generac power inlet boxes should be installed by a professional electrician familiar with electrical wiring and code.

Documentos relacionados - 6346

Preview Generac 100 Amp Guía de instalación del interruptor de transferencia automática/centro de carga con kit de instalación rápida
Guía de instalación completa para Generac 100 Amp Modelos de interruptores de transferencia automática/centros de carga, incluyendo el kit de instalación rápida. Aprenda a instalar y conectar de forma segura su sistema de generador de reserva, incluyendo la preparación del sitio, el cableado y las conexiones finales.
Preview Generac HTS "Wn" Type Automatic Transfer Switch Owner's Manual
Owner's Manual for the Generac HTS "Wn" Type Automatic Transfer Switch, detailing installation, operation, and maintenance for models 600-2600 Amp, 600 Volts.
Preview Generac 100 Amp Load Manager Owner's Manual - Installation, Operation, and Troubleshooting
This comprehensive owner's manual provides detailed information on the Generac 100 Amp Load Manager (Model G0070061), covering installation, setup, safety precautions, operation, and troubleshooting for effective generator load management.
Preview Manual del propietario del generador portátil Generac XG10000E
Manual del propietario completo del generador portátil Generac XG Professional Series XG10000E, que cubre el funcionamiento seguro, el mantenimiento, la resolución de problemas y la información de la garantía.
Preview Manual del propietario del generador de reserva Generac - Modelos QT 5.4L 80kW
Manual completo del propietario para grupos electrógenos de emergencia Generac QT de 5.4 L y 80 kW. Abarca la seguridad, el funcionamiento, el mantenimiento, la resolución de problemas y las especificaciones para un respaldo de energía confiable.
Preview Generadores de reserva Generac Protector Series: Especificaciones, características y guía de instalación
Explore la serie Generac Protector de generadores de reserva gaseosos refrigerados por líquido (25-60 kW). Este documento detalla las especificaciones del modelo, características clave como la tecnología True Power™, controladores avanzados, consumo de combustible e información sobre el diseño de la instalación.