1. Introducción

The FLIR MR77 Pinless Moisture Meter is a professional-grade instrument designed for accurate moisture and environmental measurements. This device combines pinless moisture detection with an external pin probe, relative humidity, and temperature sensing capabilities, making it a versatile tool for various applications.

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your FLIR MR77 meter to ensure optimal performance and longevity.

2. Desembalaje y contenido

Carefully unpack all items from the packaging. Verify that all components are present and undamaged. If any items are missing or damaged, contact your supplier immediately.

Contenido del paquete:

FLIR MR77 Pinless Moisture Meter

Figure 2.1: The FLIR MR77 Pinless Moisture Meter with its integrated sensor and display.

3. Configuración e instalación de la batería

3.1 Instalación de la batería

  1. Localice el compartimiento de la batería en la parte posterior del medidor.
  2. Abra la tapa del compartimiento de la batería.
  3. Insert the included 9V battery, observing correct polarity.
  4. Cierre bien la tapa del compartimento de la batería.

3.2 Attaching Sensors

The MR77 comes with an integrated pinless sensor and ports for external sensors.

External Temperature and Relative Humidity Sensor

Figure 3.1: The external temperature and relative humidity sensor (MR01).

Pin Probe and Cable

Figure 3.2: The pin probe (MR02) for penetrating moisture measurements.

4. Instrucciones de funcionamiento

4.1 Encendido / Apagado

Presione el Fuerza button (usually located at the bottom of the device) to turn the meter on or off.

4.2 Visualización sobreview

Close-up of FLIR MR77 display showing moisture and temperature readings

Figure 4.1: Close-up of the MR77 display showing various readings.

The backlit LCD displays moisture readings, relative humidity, air temperature, dew point, and other relevant data. Icons indicate measurement mode, battery status, and other functions.

4.3 Modos de medición

The FLIR MR77 offers multiple measurement capabilities:

Hand holding FLIR MR77 performing a pinless moisture measurement

Figure 4.2: Performing a pinless moisture measurement with the FLIR MR77.

Hand holding FLIR MR77 using the integrated IR thermometer with laser pointer

Figure 4.3: Using the integrated IR thermometer with laser targeting.

4.4 Material Group Selection

The MR77 allows selection of different material groups for more accurate moisture readings. Refer to the "Material Group Reference" table in the Specifications section for details on specific materials.

FLIR MR77 display showing material group and relative humidity

Figure 4.4: The display indicating the selected material group (M09) and Relative Humidity (RH).

4.5 Almacenamiento y recuperación de datos

Utilice el ALMACENAR/RECUPERAR button to save and retrieve measurement data. Consult the full user manual for detailed instructions on data logging and management.

4.6 Meter Link Smartphone App

The FLIR MR77 can connect to a smartphone app via Bluetooth for enhanced data monitoring, comparison, and reporting. Download the Meter Link app from your device's app store.

Screenshots of the FLIR Meter Link smartphone app showing data logging and comparison features

Figure 4.5: The Meter Link smartphone app interface for data monitoring and comparison.

5. Mantenimiento

5.1 Limpieza

Limpie el exterior del medidor con publicidad.amp cloth. Do not use abrasive cleaners or solvents. Keep the sensor areas clean and free of debris.

5.2 Reemplazo del sensor

The temperature/relative humidity sensor (MR01) is field-replaceable. If readings become inaccurate or the sensor is damaged, replace it with an authorized FLIR replacement part. Refer to the full user manual for detailed replacement instructions.

5.3 Almacenamiento

Store the FLIR MR77 in a cool, dry place when not in use. Remove the battery if storing for extended periods to prevent leakage.

6. Solución de problemas

ProblemaPosible causaSolución
El medidor no se enciende.Batería muerta o instalada incorrectamente.Verifique la polaridad de la batería, reemplace la batería.
Lecturas de humedad inexactas.Incorrect material group selected; sensor dirty or damaged; external interference.Verify material group; clean or replace sensor; move away from strong electromagnetic fields.
Inaccurate RH/Temperature readings.Sensor sucio o dañado.Clean or replace the MR01 sensor.
Problemas de conectividad Bluetooth.Meter not in pairing mode; app issues; distance from device.Ensure meter Bluetooth is active; restart app/meter; reduce distance.

For further assistance, refer to the official FLIR MR77 User Manual (PDF) or contact FLIR customer support.

7. Especificaciones

Especificaciones generales:

Especificaciones de medición:

FLIR MR77 Specifications including moisture and environmental measurements

Figure 7.1: Detailed specifications for the FLIR MR77.

Material Group Reference:

Table of Material Group Reference for FLIR MR77

Figure 7.2: Reference table for selecting appropriate material groups for moisture measurements.

This table provides common names of timbers and other materials, along with their corresponding material group numbers (e.g., Group 1-8 for timbers, Group 9 for plywood, drywall, and oriented strand board, Group 10 for brick, cement screed, and concrete, Group 11 for cement mortar, anhydrite screed, lime mortar, and plaster). Groups 10 and 11 are not specified for accuracy and should be used for reference only.

8. Información de garantía

The FLIR MR77 Pinless Moisture Meter is covered by a Garantía limitada de por vida. For specific terms and conditions, including details on coverage and how to make a warranty claim, please refer to the official warranty documentation provided with your product or visit the FLIR websitio.

9. Soporte y recursos adicionales

For further information, technical support, or to access the complete user manual, please use the resources below:

Documentos relacionados - MR77

Preview Manual del usuario del FLIR MR77: Psicrómetro de humedad sin pines con termómetro infrarrojo y Bluetooth
Manual de usuario del FLIR MR77, un psicrómetro de humedad sin pines con termómetro infrarrojo y conectividad Bluetooth METERLiNK. Conozca sus características, funcionamiento y especificaciones.
Preview Manual del usuario del FLIR MR77: Psicrómetro de humedad sin clavijas con termómetro IR
Manual de usuario del FLIR MR77, un psicrómetro de humedad sin pines con termómetro infrarrojo y conectividad Bluetooth METERLiNK. Conozca sus características, funcionamiento y especificaciones técnicas.
Preview Guía de inicio rápido del medidor de humedad con sonda esférica FLIR MR59
Guía de inicio rápido para el medidor de humedad con sonda de bola FLIR MR59 con Bluetooth, que cubre configuración, funcionamiento, descripción del medidor, botones de función, indicadores de pantalla y conectividad Bluetooth.
Preview Manual del usuario del medidor de humedad con imágenes FLIR MR176 Plus con IGM
User manual for the FLIR MR176 Imaging Moisture Meter Plus, detailing its features, operation, maintenance, and specifications. Learn how to use its thermal imaging, pinless, and pin probe moisture measurement capabilities.
Preview Kit de accesorios FLIR E60: Lista completa de accesorios para cámaras térmicas
Lista detallada de accesorios para la cámara termográfica FLIR E60, incluidos estuches, cables, fuentes de alimentación, cargadores, baterías, tarjetas de memoria y documentación de Advanced Test Equipment Corp.
Preview Ficha técnica de la cámara térmica FLIR serie iXX con LTE y habilitada para aplicación
Especificaciones y características detalladas de la cámara térmica FLIR iXX-Series con LTE y control mediante aplicación, incluyendo resolución IR, sensibilidad, campo de visión, aplicaciones y datos físicos.