1. Introducción
The CyberPower Smart App LCD OR2200LCDRT2U is a rack/tower convertible Uninterruptible Power Supply (UPS) system designed to provide reliable battery backup and surge protection. It features line interactive topology and Automatic Voltage Regulation (AVR) to safeguard office servers, networking hardware, workgroup servers, workstations, and telecom installations. This manual provides essential information for the proper setup, operation, and maintenance of your UPS system.

Figura 1: Frente view of the CyberPower OR2200LCDRT2U UPS System, showcasing the LCD panel and ventilation.
2. Características principales
- 2200VA/1320W Battery Backup: Provides guaranteed power protection for critical equipment.
- 8 tomas de corriente NEMA 5-20R: Offers both battery backup and surge protection.
- Multifunction LCD Screen: Displays real-time information including runtime in minutes, battery status, and power conditions.
- Vol automáticotage Regulación (AVR): Corrects minor power fluctuations without switching to battery power, extending battery life.
- 2U Rack/Tower Convertible Design: Flexible installation options for various environments.
- PowerPanel Business Edition Management Software: Free downloadable software for comprehensive UPS management.

Figure 2: Rear panel of the UPS, highlighting the NEMA 5-20R outlets, communication ports, and expansion slot.
3. Instrucciones de configuración
3.1 Desembalaje e inspección
Carefully unpack the UPS system and inspect it for any shipping damage. Ensure all components listed in the packing list are present. If any damage or missing items are found, contact your dealer or CyberPower immediately.
3.2 Colocación
The OR2200LCDRT2U can be installed in a 2U rackmount configuration or as a tower. Ensure adequate ventilation around the unit. Avoid placing the UPS near heat sources or in direct sunlight.

Figure 3: Multiple CyberPower UPS units rack-mounted in a data center environment, demonstrating typical installation.
3.3 Conexión a la alimentación
- Connect the UPS power cord (NEMA 5-20P right angle plug) to a properly grounded 20A wall outlet.
- Plug your equipment into the 8 NEMA 5-20R outlets on the rear panel. Prioritize critical equipment for battery backup outlets.
3.4 Carga inicial de la batería
For optimal performance, charge the UPS batteries for at least 8 hours before initial use. The unit will charge automatically when connected to AC power.
4. Instrucciones de funcionamiento
4.1 Encendido / Apagado
Press the power button on the front panel to turn the UPS on or off. The LCD will illuminate and display status information.
4.2 Pantalla LCD y controles
The multifunction LCD provides real-time status updates. Use the navigation buttons (Tab, Enter, Up/Down, Esc) to view various parameters such as input/output voltage, capacidad de la batería, porcentaje de cargatage, y tiempo de ejecución estimado.
Video 1: An official CyberPower video demonstrating the features and operation of the Smart App Sinewave UPS Systems, including the multifunction LCD and power management capabilities.
4.3 Vol automáticotage Regulación (AVR)
El UPS corrige automáticamente los volúmenes menorestage fluctuations (sags and surges) without switching to battery power. This ensures stable power delivery to connected devices and prolongs battery life.
5. Mantenimiento
5.1 Reemplazo de batería
The OR2200LCDRT2U uses four 12V sealed lead-acid batteries. Batteries are user-replaceable. Refer to the detailed battery replacement guide for your specific model. Always use genuine CyberPower replacement batteries to ensure compatibility and safety.
Video 2: A user-generated video demonstrating the process of replacing ExpertPower batteries in a CyberPower UPS. While not an official CyberPower video, it illustrates the general procedure for battery replacement.
5.2 Limpieza
Limpie periódicamente el exterior del SAI con un paño seco. Asegúrese de que las aberturas de ventilación estén libres de polvo y residuos para evitar el sobrecalentamiento.
6. Solución de problemas
If the UPS is not functioning correctly, consult the following common issues:
- Sin energía: Check the power cord connection to the wall outlet and the UPS. Ensure the power button is pressed.
- Duración corta de la batería: Batteries may be old or not fully charged. Allow 8 hours for charging or consider battery replacement.
- Alarma de sobrecarga: Disconnect non-essential equipment from the UPS to reduce the load.
- UPS Not Providing Backup: Ensure the UPS is connected to a live AC outlet and the batteries are charged.
For further assistance, refer to the full user manual or contact CyberPower support.
7. Especificaciones
| Atributo | Valor |
|---|---|
| Número de modelo | OR2200LCDRT2U |
| Capacidad (VA / W) | 2200 VA/1320 W |
| Salidas de salida | 8NEMA 5-20R |
| Enchufe de entrada | NEMA 5-20P (right angle, 10 ft cord) |
| Topología | Línea interactiva |
| Vol automáticotage Regulación (AVR) | Sí |
| Tipo de batería | Batería de plomo-ácido sellada (4 x 12 V incluida) |
| Dimensiones del producto | 17.25 x 15.75 x 3.5 pulgadas |
| Peso del artículo | 52.7 libras |
| Volumentage | 120 voltios |
| Color | Negro |

Figure 4: Dimensions of the CyberPower OR2200LCDRT2U UPS, showing its compact 2U form factor.
8. Garantía y soporte
8.1 Información de garantía
The CyberPower OR2200LCDRT2U comes with a 3-year warranty, which includes the batteries. It also includes a $300,000 Connected Equipment Guarantee, providing peace of mind for your connected devices.
8.2 Atención al cliente
Para asistencia técnica, resolución de problemas o reclamos de garantía, visite el sitio web oficial de CyberPower. website or contact their customer support. Free PowerPanel Business Edition Management Software is available for download to enhance monitoring and control capabilities.