1. Introducción

The PulseTech PRO-12-RP RediPulse12 Station Battery Maintenance System is designed to maintain up to twelve 12-volt lead-acid batteries, ensuring they remain fully charged and in optimal condition. This system utilizes patented Pulse Technology to prevent and reverse battery sulfation, extending battery life and maintaining peak performance. It is ideal for keeping new and lightly used batteries factory fresh during storage.

PulseTech PRO-12-RP RediPulse12 Battery Maintenance System

Figure 1: The PulseTech PRO-12-RP RediPulse12 Battery Maintenance System, showing the main unit with multiple battery leads connected.

2. Información importante de seguridad

Read all instructions carefully before using the PulseTech PRO-12-RP. Failure to follow these safety guidelines may result in injury or damage to the product or property.

3. Características principales

PulseTech RediPulse12 maintaining twelve 12-volt lead-acid batteries

Figure 2: The RediPulse12 system connected to multiple 12-volt lead-acid batteries, demonstrating its capacity to maintain up to twelve batteries.

PulseTech RediPulse12 with 'Plug and Play' technology

Figure 3: The RediPulse12 unit highlighting its user-friendly 'plug and play' design for easy setup and operation.

PulseTech RediPulse12 LED indicators for battery condition

Figure 4: Close-up of the RediPulse12 showing the LED indicators, which provide visual feedback on the charge status of each connected battery.

4. Instrucciones de configuración

Follow these steps to set up your PulseTech PRO-12-RP system:

  1. Colocación: Place the RediPulse12 unit in a dry, well-ventilated area, away from direct sunlight or heat sources. Ensure it is not installed in a vehicle.
  2. Preparación de la batería: Ensure the 12-volt lead-acid batteries you intend to maintain are clean and in good working order. For deeply discharged batteries (below 11.5 volts) or heavily sulfated batteries, it is recommended to fully charge them with a standard battery charger before connecting to the RediPulse12.
  3. Conecte los cables de la batería: Connect the RediPulse12's output leads to the terminals of each battery. Ensure the red clamp Se conecta al terminal positivo (+) y al terminal negro.amp connects to the negative (-) terminal. The system is designed to prevent sparking during connection.
  4. Verificar conexión: After connecting each battery, check the corresponding LED indicator on the RediPulse12 unit. If an audible alarm sounds, a battery is connected improperly. Disconnect the power cord from the AC outlet, correct the connection, and then reconnect the power.
  5. Conexión de energía: Once all batteries are correctly connected, plug the AC power cord of the RediPulse12 unit into a standard 120V AC wall outlet.
  6. Operation Confirmation: The LEDs for each connected battery should illuminate, indicating that the system is actively maintaining the batteries.

5. Instrucciones de funcionamiento

The PulseTech PRO-12-RP operates automatically once connected and powered. It provides continuous maintenance to keep your batteries in optimal condition.

PulseTech RediPulse12 in operation, showing continuous low amp charge and pulse technology

Figure 5: The RediPulse12 system actively maintaining batteries, illustrating the benefits of continuous low-amp charging and patented pulse technology for sulfation reversal.

6. Mantenimiento

The PulseTech PRO-12-RP is designed for minimal maintenance. However, regular checks can ensure optimal performance and longevity of both the unit and your batteries.

7. Solución de problemas

This section addresses common issues you might encounter with your RediPulse12 system.

ProblemaPosible causaSolución
No LEDs illuminate when connected to power and batteries.
  • Sin alimentación de CA.
  • Improper battery connection.
  • Unidad defectuosa.
  • Check if the AC power cord is securely plugged into a live outlet.
  • Disconnect AC power, verify all battery connections (red to positive, black to negative), then reconnect AC power.
  • If the problem persists, contact PulseTech customer support.
Suena una alarma audible.Improper battery connection (e.g., reverse polarity).Disconnect AC power immediately. Correct the battery connection (red to positive, black to negative). Reconnect AC power.
Battery does not seem to be maintained or charged.
  • Battery is deeply discharged (below 11.5V).
  • Battery is heavily sulfated.
  • La batería está defectuosa.
  • The RediPulse12 is a maintenance system, not a primary charger for deeply discharged batteries. Use a standard charger to bring the battery above 11.5V before connecting to the RediPulse12.
  • Heavily sulfated batteries may require a dedicated desulfator or a full charge cycle with a standard charger first.
  • Test the battery with a battery tester. If faulty, replace the battery.

8. Especificaciones

CaracterísticaDetalle
Número de modeloPRO-12-RP
MarcaPulseTech
Compatibilidad de la batería12-Volt Lead-Acid Batteries (VRLA, AGM, Gel, Flooded Cell)
Number of Batteries MaintainedHasta 12
Vol de entradatage120 V CA (tomacorriente estándar de EE. UU.)
Vol de salidatage12 voltios CC
Corriente de salidaContinuous Low Amp Cargar
TecnologíaPatented Pulse Technology
Dimensiones (L x An x Al)7.25 x 2.25 x 1 pulgadas
Peso del artículo0.01 onzas
FabricantePulseTech

9. Garantía y soporte

For warranty information and customer support regarding your PulseTech PRO-12-RP RediPulse12 Station Battery Maintenance System, please refer to the documentation included with your product or visit the official PulseTech websitio.

PulseTech Products is committed to providing high-quality battery maintenance solutions. For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact PulseTech customer service directly.

Puede encontrar más información y datos de contacto en el PulseTech Brand Store on Amazon o su empresa oficial websitio.