Introducción
This manual provides essential information for the safe and efficient operation of your Sharp AHXP13NRV Split Air Conditioner. Please read this manual thoroughly before using the appliance and keep it for future reference. This 1.1 Ton Split AC is designed to provide a cool and comfortable indoor environment, featuring advanced technologies for air purification and energy efficiency.

This image displays the white indoor unit of the Sharp AHXP13NRV Split AC, featuring the Sharp logo and 'ECO INVERTER' branding on the front panel.
Características principales
- Plasma cluster Ion Technology: Releases natural levels of positive and negative ions into the air to remove bacteria, mold, airborne viruses, and other contaminants.
- Control del inversor: Modifies and maintains room temperature by switching the compressor between high and low operation modes, ensuring comfortable, even temperature control with high power savings.
- Super Jet: Delivers a powerful blast of cool air for instant cooling.
- Gentle Cool Air (Coanda Technology): Provides an all-embracing airflow from the ceiling to the walls, spreading cool air throughout the room for a pleasant environment, ideal for sensitive individuals.
- Función de lavandería: Assists in drying laundry indoors by blowing air on wet clothing, followed by dehumidification and Plasmacluster Ion emission to suppress odors.
- Instant Low Wattage / Eco Mode: Allows setting the air conditioner to energy-saving mode via a two-stage adjustment, limiting power consumption and preventing over-cooling.
- Refrigerante R410A: Uses an environmentally friendly refrigerant with no adverse impact on the ozone layer.
- Control por microordenador: Includes Auto Operation, Auto Sleep, and Auto Restart modes for convenient and efficient operation.
- 3-Step Fan Speed Settings: Allows selection of comfortable fan speeds, with an option for automatic fan speed adjustment.
- LCD Wireless Remote: Enables easy operation and control of the unit.
- Nature Wing Fan Blades: Designed to optimize airflow and boost air circulation efficiency, contributing to energy savings.
Configuración e instalación
The Sharp AHXP13NRV is a split-system air conditioner, requiring professional installation. Ensure that installation is performed by a qualified technician to guarantee proper functioning and safety.
Consideraciones previas a la instalación:
- Ubicación: Choose a location for both the indoor and outdoor units that allows for optimal airflow and easy maintenance.
- Fuente de alimentación: Ensure the electrical supply meets the unit's requirements (240 Volts, 1150 Watts). A dedicated circuit is recommended.
- Drenaje: Planifique un drenaje de condensado adecuado de la unidad interior.
- Líneas de refrigerante: Ensure proper routing and insulation of refrigerant lines between the indoor and outdoor units.
Note: Incorrect installation can lead to reduced performance, energy inefficiency, and potential safety hazards. Always consult the detailed installation guide provided with the product or a certified technician.
Instrucciones de funcionamiento
Your Sharp AHXP13NRV Split AC is operated primarily using the provided LCD wireless remote control. Familiarize yourself with the remote's functions for optimal use.
Operación básica:
- Encendido/apagado: Utilice el botón de encendido del control remoto para encender o apagar la unidad.
- Selección de modo: Select desired operating mode (e.g., Cool, Fan, Dry, Auto) using the mode button.
- Ajuste de temperatura: Utilice los botones de subir/bajar temperatura para configurar la temperatura ambiente deseada.
- Velocidad del ventilador: Adjust fan speed (Low, Medium, High, Auto) using the fan speed button.
Funciones avanzadas:
- Operación automática: The unit automatically selects the appropriate operating mode based on the room temperature.
- Modo de reposo automático: Optimizes temperature settings during sleep for comfort and energy saving.
- Temporizador de encendido/apagado: Set specific times for the unit to turn on or off automatically. Refer to the remote control's instructions for detailed timer setup.
- Función de lavandería: Activate this mode to assist in drying clothes indoors. The unit will blow air on wet clothing, then switch to dehumidifier function with Plasmacluster Ions to remove moisture and odors.
- Eco Mode / Instant Low Wattage: Engage this mode to reduce power consumption. The unit will operate at a lower wattage, ideal for energy saving.
- Super Jet Mode: For rapid cooling, activate the Super Jet function. This delivers a powerful burst of cool air.
- Gentle Cool Air Mode: For a softer, more diffused cooling experience, select this mode. It utilizes Coanda technology to spread air gently.
Mantenimiento
Regular maintenance ensures the longevity and efficient operation of your Sharp AHXP13NRV Split AC. Always disconnect power before performing any maintenance.
- Limpieza del filtro de aire: Clean the air filters regularly (e.g., every two weeks or as needed) to maintain optimal airflow and air quality. Refer to the product manual for instructions on how to remove and clean the filters.
- Función de autolimpieza: Utilize the unit's self-cleaning feature to help prevent mold and bacteria buildup inside the indoor unit.
- Limpieza de la unidad exterior: Keep the outdoor unit free from obstructions, leaves, and debris to ensure proper heat exchange.
- Servicio Profesional: Schedule annual professional servicing to check refrigerant levels, clean coils, and inspect electrical components.
- Plasmacluster Ion Maintenance: The Plasmacluster Ion generator requires no special maintenance, as it continuously cleans the air.
Solución de problemas
Antes de ponerse en contacto con el servicio de atención al cliente, consulte los siguientes problemas comunes y sus posibles soluciones:
| Problema | Posible causa | Solución |
|---|---|---|
| La unidad no se enciende. | No power supply; remote control batteries are dead; circuit breaker tripped. | Verifique la conexión de energía; reemplace las baterías del control remoto; reinicie el disyuntor. |
| Refrigeración insuficiente. | Filtros de aire sucios; unidad exterior bloqueada; ventanas/puertas abiertas; habitación demasiado grande. | Limpie los filtros de aire; elimine las obstrucciones de la unidad exterior; cierre las ventanas y puertas; asegúrese de que la capacidad de la unidad coincida con el tamaño de la habitación. |
| Ruido inusual. | Piezas sueltas; objetos extraños en el ventilador; unidad desnivelada. | Revise si hay piezas sueltas; retire objetos extraños; asegúrese de que la unidad esté nivelada. Si el ruido persiste, contacte con el servicio técnico. |
| Fuga de agua de la unidad interior. | Tubería de drenaje obstruida; instalación incorrecta. | Check and clear drain pipe; contact a professional for inspection if installation is suspected. |
Si el problema persiste después de intentar estas soluciones, comuníquese con el servicio de atención al cliente de Sharp.
Presupuesto
| Atributo | Detalle |
|---|---|
| Marca | Afilado |
| Modelo | AHXP13NRV |
| Capacidad | 1.1 toneladas |
| Eficiencia energética | High Efficiency (BEE 5 Star Rating) |
| Nivel de ruido | 39 dB |
| Tipo de instalación | Sistema dividido |
| Color | Blanco |
| Consola de control | Remote Control (LCD) |
| Volumentage | 240 voltios |
| Quétage | 1150 vatios |
| Potencia de enfriamiento | 1010 vatios |
| Refrigerante | R410A |
| Dimensiones del artículo (LxWxH) | 29 x 92 x 24 centímetros |
Garantía y soporte
Your Sharp AHXP13NRV Split AC comes with a comprehensive warranty to ensure peace of mind:
- Garantía del producto: 1 año en todo el producto.
- Garantía del compresor: 5 años en el compresor.
For warranty claims, technical assistance, or service requests, please contact Sharp customer support. Ensure you have your product model number (AHXP13NRV) and purchase details readily available when contacting support.