Dickson C662

Manual de instrucciones de la tarjeta gráfica Dickson C662

Model: C662 | Brand: Dickson

Producto terminadoview

The Dickson C662 Chart is a specialized replacement chart designed for use with compatible circular chart recorders. This 6-inch diameter chart is calibrated for 24-hour recording cycles and features a measurement range of 0 to +500 units, making it suitable for various industrial and scientific data logging applications. It serves as a consumable component essential for accurate and continuous data visualization.

Dickson C662 6-inch circular chart with grid lines and numerical scales.

Figure 1: Dickson C662 6-inch circular chart. This image displays the Dickson C662 circular chart, designed for 24-hour recording. The chart features a detailed grid with radial and concentric lines, indicating time and measurement values. The center of the chart includes the 'DICKSON' brand name and model information. The outer edge is marked with time increments, and the inner area shows measurement scales ranging from 0 to +500.

Configuración e instalación

Proper installation of the Dickson C662 chart is crucial for accurate data recording. Follow these steps to replace or install a new chart in your compatible circular chart recorder:

  1. Apagado: Before handling the chart recorder, ensure the device is powered off or disconnected from its power source to prevent accidental operation or damage.
  2. Open Recorder: Carefully open the chart recorder's cover or access panel to expose the chart mounting mechanism.
  3. Remove Old Chart (if applicable): If replacing an existing chart, gently lift the pen arm(s) away from the chart surface and remove the used chart from the center hub. Dispose of the used chart responsibly.
  4. Align New Chart: Take a new Dickson C662 chart. Locate the center hole and align it with the chart recorder's center hub. Ensure the chart lies flat and is properly seated.
  5. Establecer hora/fecha: Rotate the chart until the current time and date on the chart align with the recorder's time indicator or pen position. This ensures accurate time-based recording.
  6. Lower Pen Arm(s): Carefully lower the pen arm(s) back onto the chart surface. Ensure the pen tip makes proper contact without excessive pressure.
  7. Close Recorder: Securely close the chart recorder's cover or access panel.
  8. Encendido: Reconnect power to the chart recorder and verify that the chart is rotating correctly and the pen(s) are marking as expected.

Note: Always refer to your specific chart recorder's manual for detailed installation instructions, as procedures may vary slightly between models.

Directrices de funcionamiento

Once installed, the Dickson C662 chart operates in conjunction with your chart recorder to provide a visual record of measured parameters. To ensure optimal performance and accurate data capture:

Mantenimiento y almacenamiento

Proper handling and storage of Dickson C662 charts will preserve their quality and ensure readiness for use:

Solución de problemas

While the Dickson C662 chart is a passive component, issues related to its interaction with the recorder can occur. Consider the following if you encounter problems:

Presupuesto

AtributoDetalle
Número de modeloC662
MarcaDickson
Diámetro del gráfico6 pulgadas
Periodo de grabación24 horas
Rango de medición0 a +500
Dimensiones del paquete3.94 x 3.94 x 3.94 pulgadas
Peso del artículo10.56 onzas
FabricanteThomas Científico
ASINB00VGDSFDO
Fecha de primera disponibilidad31 de marzo de 2015

Garantía y soporte

As the Dickson C662 Chart is a consumable item, specific warranty information typically applies to the chart recorder itself rather than the individual charts. For details regarding product warranty, returns, or technical support, please refer to the documentation provided with your chart recorder or contact the manufacturer of the chart recorder directly.

For inquiries related to the Dickson C662 charts, please contact your supplier or the manufacturer, Thomas Scientific, for assistance.

Documentos relacionados - C662

Preview Registradores de temperatura Dickson serie KT8: Manual del usuario y guía de inicio rápido
Guía completa para los registradores de temperatura de detección remota Dickson de las series KT8P, KT8P2, KT8P3 y KT856. Abarca la configuración, el funcionamiento, las alarmas, los interruptores DIP, la calibración, la resolución de problemas y la información sobre la garantía.
Preview Registrador de procesos DICKSON HT350: Guía del usuario y configuración
Guía completa para configurar, usar y solucionar problemas del registrador de procesos DICKSON HT350, incluida la instalación del software, el registro de datos y la información de la garantía.
Preview Manual del usuario y guía del producto del registrador gráfico Dickson de 8" de una y dos plumas
Este manual de usuario y guía del producto proporciona instrucciones detalladas para operar y configurar los registradores gráficos Dickson de 8" de una y dos plumas, incluida la configuración, las opciones de menú, los códigos de error y las especificaciones del modelo.
Preview Curso de formación ThermoServer / ThermoClientview | DICKSON
detallada sobreview Este curso de formación sobre DICKSON ThermoServer/ThermoClient abarca la arquitectura del sistema, el hardware, el software, el mantenimiento, la resolución de problemas y los objetivos de aprendizaje. Está dirigido a nuevos usuarios y administradores.
Preview Guía de inicio rápido del registrador de pantalla USB Dickson DSB
Guía de inicio rápido para el registrador de pantalla USB Dickson DSB, que cubre la instalación, la configuración mediante DicksonWare, los métodos de descarga de datos y los sensores reemplazables.
Preview Dickson ES120/ES120A Electronic Signal Data Logger - Manual & Specifications
Comprehensive guide for the Dickson ES120 and ES120A Electronic Signal Data Loggers, covering product applications, specifications, operating instructions, software, FAQs, and warranty.