Modelo MSA 801582

MSA Safety 801582 SampManual de instrucciones del filtro de agua Le Probe Passport

Modelo: 801582

1. Introducción

This instruction manual provides essential information for the proper installation, operation, and maintenance of the MSA Safety 801582 Sample Probe Passport Water Stop Filter. This product is designed to prevent water ingress into gas detection equipment, ensuring accurate readings and protecting sensitive internal components. Please read this manual thoroughly before use to ensure safe and effective operation.

2. Producto terminadoview y componentes

The MSA Safety 801582 Water Stop Filter is a critical accessory for sample probe systems, designed to halt the flow of water and protect connected instruments. Each pack contains 10 individual filters.

Pack of 10 MSA Safety 801582 Water Stop Filters

Figura 1: A pack of ten MSA Safety 801582 Sample Probe Passport Water Stop Filters. These filters are designed to prevent water from entering gas detection equipment.

Each filter unit consists of a durable plastic housing with inlet and outlet ports, containing a specialized membrane or material that stops water while allowing gas samples to pass through. The compact design facilitates easy integration into existing samplas líneas.

Close-up of a single MSA Safety 801582 Water Stop Filter

Figura 2: Un detallado view of a single MSA Safety 801582 Water Stop Filter, showing its clear plastic body and connection ports. The filter is marked with "ADVANTEC JP050AN".

3. Configuración e instalación

Proper installation is crucial for the effective performance of the water stop filter. Follow these steps carefully:

  1. Identificar puntos de conexión: Determinar la sample line where water ingress is a potential issue. The filter should be installed between the sample probe and the gas detection instrument.
  2. Garantizar la compatibilidad: Verify that the filter's connection ports are compatible with your existing sample tubing. The filter is designed for use with MSA Passport systems.
  3. Orientarse correctamente: Observe the flow direction indicated on the filter body (if present) or ensure the filter is positioned to intercept water before it reaches the instrument. Typically, the wider end connects to the sample source, and the narrower end to the instrument.
  4. Conexiones seguras: Conectar el sample tubing securely to both the inlet and outlet ports of the filter. Ensure all connections are tight to prevent leaks, which could compromise sample integrity or filter effectiveness.
  5. Sistema de prueba: After installation, perform a system leak test according to your gas detection equipment's manual to confirm proper sealing and functionality.

Warning: Do not force connections. Incorrect installation can lead to leaks or damage to the filter and connected equipment.

4. Instrucciones de funcionamiento

Once installed, the MSA Safety 801582 Water Stop Filter operates passively as part of your sample line. It requires no active user input during normal operation.

  • Monitoreo continuo: The filter continuously prevents water from reaching your gas detection sensor while allowing the gas sample to pass through.
  • Inspección visual: Periodically inspect the transparent body of the filter for any signs of accumulated water or discoloration, which indicates the filter is performing its function and may require replacement.
  • Restricción de flujo: A significant accumulation of water or particulate matter within the filter may cause a noticeable restriction in sample flow. This is an indication that the filter needs immediate replacement.

5. Mantenimiento

The MSA Safety 801582 Water Stop Filter is a disposable component and is not designed for cleaning or reuse. Regular inspection and timely replacement are the primary maintenance activities.

  • Frecuencia de inspección: Inspect the filter daily or before each use, especially in environments where water exposure is likely.
  • Reemplazo: Replace the filter immediately if:
    • Water is visible inside the filter housing.
    • There is a noticeable reduction in sample flujo.
    • The filter material appears discolored or damaged.
    • The filter has been exposed to a significant amount of moisture.
  • Desecho: Dispose of used filters according to local regulations for industrial waste.
  • Almacenamiento: Store unused filters in their original packaging in a cool, dry place, away from direct sunlight and extreme temperatures.

6. Solución de problemas

Problema Posible causa Solución
Reduced sample flow to instrument Filter is clogged with water or particulate matter. Replace the water stop filter.
Water detected in gas detection instrument Filter is compromised or improperly installed. Inspect filter for damage. Ensure connections are secure. Replace filter if necessary.
Filter appears discolored or damaged Exposure to harsh chemicals or physical stress. Reemplace el filtro inmediatamente.

7. Especificaciones

Característica Detalle
Número de modelo 801582
Tipo de producto Sample Probe Passport Water Stop Filter
Marca Seguridad de MSA
Material Durable Plastic (Filter Body), Stainless Steel (Internal/Connectors - as per manufacturer specifications)
Dimensiones del producto 3 x 2 x 0.1 inches (approximate, individual filter)
Peso del artículo 0.48 ounces (individual filter)
Recuento de unidades 10 filtros por paquete
Certificación de pruebas externas CE
Código Postal 641817010266
Beneficio principal Prevents water ingress, reduces PFAS (as per product benefits)

8. Garantía y soporte

For specific warranty information regarding the MSA Safety 801582 Sample Probe Passport Water Stop Filter, please refer to the documentation provided with your original purchase or contact MSA Safety directly. As a consumable item, filters typically have a limited warranty against manufacturing defects.

For technical support, product inquiries, or to purchase replacement filters, please visit the official MSA Safety websitio o contacte con su departamento de atención al cliente. Puede encontrar más información en el MSA Safety Store on Amazon o su empresa websitio.

Documentos relacionados - 801582

Preview Manual de funcionamiento del software MSA A2: Control de rendición de cuentas
Manual de operación completo del software MSA A2, un sistema de control de responsabilidad diseñado para la monitorización en tiempo real de equipos de seguridad, como ERA y dispositivos relacionados, en operaciones críticas. Abarca la configuración, el uso y las funciones para una mejor gestión de la seguridad.
Preview Guía del usuario del dispositivo portátil de detección de gases MSA ALTAIR io 4
Esta guía del usuario proporciona instrucciones completas para el dispositivo portátil de detección de gases MSA ALTAIR io 4, que abarca avisos de seguridad, configuración, funcionamiento, características, mantenimiento y resolución de problemas.
Preview Manual del usuario del casco protector MSA F2 X-TREM
El casco MSA F2 X-TREM es un casco de protección versátil, diseñado para diversas aplicaciones, como extinción de incendios forestales, operaciones de rescate y montañismo. Este manual de usuario proporciona información esencial sobre su uso correcto, ajuste, mantenimiento y accesorios disponibles, garantizando así una seguridad y un rendimiento óptimos.
Preview Manual de funcionamiento del detector de gas único MSA ALTAIR Pro - Guía de seguridad y uso
Este manual de funcionamiento proporciona instrucciones detalladas, pautas de seguridad, procedimientos de calibración y solución de problemas para el detector de gas único MSA ALTAIR Pro. Aprenda a usar y mantener eficazmente su instrumento de detección de gases.
Preview Manual de utilización Centrale GasGard XL, lunestagMural electrónico MSA
Manual de uso completo para la central de alarma de gas MSA GasGard XL, lunestagel mural. Instrucciones de instalación, utilización, configuración y mantenimiento para la seguridad industrial.
Preview Sonda de bomba MSA ALTAIR: Detector de gas duradero para entornos peligrosos
Explore la sonda de bomba ALTAIR de MSA, un instrumento de detección de gases robusto y fiable. Conozca sus características principales, especificaciones técnicas, homologaciones e información de pedido para aplicaciones de seguridad industrial.